Restek
Home / Reference Standards / Multi-Component / VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
Restek
New
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
  1. VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit

VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit

Catalog No. 30675
$540.00
Shipping Note
Reference standards shipped after December 31, 2023, will no longer include paper hard copies of certificates of analysis (CofAs). Access your CofA online at www.restek.com/documentation
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit

VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit

$540.00

Overview

Features & Benefits
  • Single kit comprised of 131 compounds commonly analyzed in volatiles testing, reducing sample prep time and variability.
  • High analyte concentration allows for flexibility in constructing calibration solutions.
  • Two independent lots available to meet your quality control requirements.
  • Useful for EPA 8260 or other volatiles analyses.

Note: Pentachloroethane (Cat.# 30404) is provided as a separate standard in this kit in order to allow for running a system check of this standard before beginning your analyses or to provide flexibility in leaving this standard out of your calibration solutions if pentachloroethane does not need to be reported. Several issues can cause pentachloroethane to convert into tetrachloroethene during an analysis, and the resulting elevated level of tetrachloroethene and low-biased pentachloroethane response may lead to failed proficiency tests (PTs) when analyzing VOCs in solid waste by EPA Method 8260.

Description

Contains one ampul of each of the following:

Cat.# 30152: 8260 MegaMix Calibration Mix, Revised
2000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
Acetonitrile 75-05-8
Acrylonitrile 107-13-1
Allyl chloride (3-chloropropene) 107-05-1
Benzene 71-43-2
Bromobenzene 108-86-1
Bromochloromethane 74-97-5
Bromodichloromethane 75-27-4
Bromoform 75-25-2
n-Butylbenzene 104-51-8
sec-Butylbenzene 135-98-8
tert-Butylbenzene 98-06-6
Carbon disulfide 75-15-0
Carbon tetrachloride 56-23-5
Chlorobenzene 108-90-7
2-Chloroethanol 107-07-3
Chloroform 67-66-3
Chloroprene (2-chloro-1,3-butadiene) 126-99-8
2-Chlorotoluene 95-49-8
4-Chlorotoluene 106-43-4
Dibromochloromethane 124-48-1
1,2-Dibromo-3-chloropropane (DBCP) 96-12-8
1,2-Dibromoethane (EDB) 106-93-4
Dibromomethane 74-95-3
1,2-Dichlorobenzene 95-50-1
1,3-Dichlorobenzene 541-73-1
1,4-Dichlorobenzene 106-46-7
cis-1,4-Dichloro-2-butene 1476-11-5
trans-1,4-Dichloro-2-butene 110-57-6
1,1-Dichloroethane 75-34-3
1,2-Dichloroethane 107-06-2
1,1-Dichloroethene 75-35-4
cis-1,2-Dichloroethene 156-59-2
trans-1,2-Dichloroethene 156-60-5
1,2-Dichloropropane 78-87-5
1,3-Dichloropropane 142-28-9
2,2-Dichloropropane 594-20-7
1,1-Dichloropropene 563-58-6
cis-1,3-Dichloropropene 10061-01-5
trans-1,3-Dichloropropene 10061-02-6
Diethyl ether (ethyl ether) 60-29-7
1,4-Dioxane 123-91-1
Ethylbenzene 100-41-4
Ethyl methacrylate 97-63-2
Hexachloro-1,3-butadiene 87-68-3
Iodomethane (methyl iodide) 74-88-4
Isobutyl alcohol (2-methyl-1-propanol) 78-83-1
Isopropylbenzene (cumene) 98-82-8
4-Isopropyltoluene (p-Cymene) 99-87-6
Methacrylonitrile 126-98-7
Methyl acrylate 96-33-3
Methyl methacrylate 80-62-6
Methylene chloride (dichloromethane) 75-09-2
Naphthalene 91-20-3
Nitrobenzene 98-95-3
2-Nitropropane 79-46-9
Propionitrile 107-12-0
n-Propylbenzene 103-65-1
Styrene 100-42-5
1,1,1,2-Tetrachloroethane 630-20-6
1,1,2,2-Tetrachloroethane 79-34-5
Tetrachloroethene 127-18-4
Tetrahydrofuran 109-99-9
Toluene 108-88-3
1,2,3-Trichlorobenzene 87-61-6
1,2,4-Trichlorobenzene 120-82-1
1,1,1-Trichloroethane 71-55-6
1,1,2-Trichloroethane 79-00-5
Trichloroethene 79-01-6
1,2,3-Trichloropropane 96-18-4
1,1,2-Trichlorotrifluoroethane (CFC-113) 76-13-1
1,2,4-Trimethylbenzene 95-63-6
1,3,5-Trimethylbenzene 108-67-8
m-Xylene 108-38-3
o-Xylene 95-47-6
p-Xylene 106-42-3

 

Cat.# 30676: Volatile MegaMix II
2000-10,000 µg/mL in Methanol, 1 mL/ampul

Compounds CAS # Conc (µg/mL)
tert-Amyl alcohol 75-85-4 10,000
tert-Amyl ethyl ether (TAEE) 919-94-8 2000
tert-Amyl methyl ether (TAME) 994-05-8 2000
Benzyl chloride 100-44-7 2000
1-Butanol 71-36-3 10,000
2-Butanol (sec-butyl alcohol) 78-92-2 2000
tert-Butanol (TBA) 75-65-0 10,000
Butyl acetate 123-86-4 2000
1-Chlorohexane 544-10-5 2000
3-Chlorotoluene 108-41-8 2000
Cyclohexane 110-82-7 2000
1,2-Diethylbenzene 135-01-3 2000
1,3-Diethylbenzene 141-93-5 2000
1,4-Diethylbenzene 105-05-5 2000
Diisopropyl ether (DIPE) 108-20-3 2000
Ethanol 64-17-5 10,000
Ethyl acetate 141-78-6 5000
Ethyl acrylate 140-88-5 2000
Ethyl-tert-butyl ether (ETBE) 637-92-3 2000
p-Ethyltoluene 622-96-8 2000
n-Heptane (C7) 142-82-5 2000
Hexachloroethane 67-72-1 2000
n-Hexane (C6) 110-54-3 2000
Isopropyl acetate 108-21-4 2000
Methyl acetate 79-20-9 5000
3-Methyl-1-butanol (isoamyl alcohol) 123-51-3 2000
Methyl-tert-butyl ether (MTBE) 1634-04-4 2000
Methylcyclohexane 108-87-2 2000
1-Methylnaphthalene 90-12-0 2000
2-Methylnaphthalene 91-57-6 2000
4-Methyl-2-pentanol 108-11-2 2000
1-Propanol 71-23-8 10,000
2-Propanol (isopropanol) 67-63-0 10,000
Propyl acetate 109-60-4 2000
1,2,4,5-Tetramethylbenzene 95-93-2 2000
1,3,5-Trichlorobenzene 108-70-3 2000
1,2,3-Trimethylbenzene 526-73-8 2000
2,2,4-Trimethylpentane (isooctane) 540-84-1 2000

 

Cat.# 30006: VOA Calibration Mix #1
5000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
Acetone 67-64-1
2-Butanone (MEK) 78-93-3
2-Hexanone 591-78-6
4-Methyl-2-pentanone (MIBK) 108-10-1

 

Cat.# 30678: Volatile Gases Standard
2000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
Bromomethane (methyl bromide) 74-83-9
1,3-Butadiene 106-99-0
Chloroethane (ethyl chloride) 75-00-3
Chloromethane methyl chloride) 74-87-3
Dichlorodifluoromethane (CFC-12) 75-71-8
Methyl ether (dimethyl ether) 115-10-6
Trichlorofluoromethane (CFC-11) 75-69-4
Vinyl chloride 75-01-4

 

Cat.# 30265: 2-Chloroethyl Vinyl Ether Standard
2000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
2-Chloroethyl vinyl ether 110-75-8

 

Cat.# 30646: Acrolein Standard
5000 ug/mL in Water, 1 mL/ampul

Compounds CAS #
Acrolein 107-02-8

 

Cat.# 30677: Cyclohexanone Standard
10,000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
Cyclohexanone 108-94-1

 

Cat.# 30679: Epichlorohydrin Standard
2000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
Epichlorohydrin (1-Chloro-2,3-epoxypropane) 106-89-8

 

Cat.# 30404: Pentachloroethane Standard
2000 ug/mL, P&T Methanol, 1 mL/ampul

Compounds CAS #
Pentachloroethane 76-01-7

 

Cat.# 30216: Vinyl Acetate Standard
2000 ug/mL in Methanol, 1 mL/ampul

Compounds CAS #
Vinyl acetate 108-05-4

Specifications

Product Specifications
Catalog No.
30675
Product Name
VOC MegaMix 131 Kit, 1 mL/ampul, 10 ampuls/kit
Can't find what you're looking for?
Custom Reference Standards

Looking for a custom reference standard? Use this form to request a custom quote.