DHA PONA Standard, Neat, 0.15 mL in Autosampler Vial
  1. DHA PONA Standard, Neat, 0.15 mL in Autosampler Vial

DHA PONA Standard, Neat, 0.15 mL in Autosampler Vial

Catalog No. 30731
$1,163.00
Shipping Note
Access your CofA online at www.restek.com/documentation
DHA PONA Standard, Neat, 0.15 mL in Autosampler Vial

DHA PONA Standard, Neat, 0.15 mL in Autosampler Vial

$1,163.00

Overview

Features & Benefits
This standard is a qualitative mixture of various gasoline and refinery materials prepared to provide nearly every component that may be encountered in feedstock and finished gasolines. Some oxygenates have been added to allow this blend to be used by refineries for Detailed Hydrocarbon Analysis (DHA) method setup and to fulfill requirements such as ASTM Methods D6729, D6730, and D6733.
Description

ASTM Methods D6729, D6730, and D6733 (Determination of Individual Components in Spark Ignition Engine Fuels) are designed for the determination of the individual hydrocarbons present in spark ignition engine fuels, as well as fuel blends containing oxygenates such as methyl tert-butyl ether, ethyl tert-butyl ether, tert-butanol, ethanol, etc.

Compound, Conc (wt/wt%)
Paraffins
N-Butane, 2.086%
N-Decane, 0.966%
N-Dodecane, 0.943%
N-Heptane, 2.479%
N-Hexane, 3.882%
N-Nonane, 1.048%
N-Octane, 1.403%
N-Pentadecane, 0.947%
N-Pentane, 4.093%
Propane, 0.251%
N-Tetradecane, 0.947%
N-Tridecane, 0.941%
N-Undecane, 0.941%
Isoparaffins
C8 Isoparaffin, 0.004%
C8 Isoparaffin, 0.007%
C8 Isoparaffin, 0.009%
C8 Isoparaffin, 0.018%
C8 Isoparaffin, 0.029%
C9 Isoparaffin, 0.018%
C11 Isoparaffin, 0.004%
C12 Isoparaffin, 0.008%
C15 Isoparaffin, 0.007%
3,3-Diethylpentane, 0.378%
2,2-Dimethylbutane, 0.233%
2,3-Dimethylbutane, 0.985%
2,2-Dimethylheptane, 0.042%
2,3-Dimethylheptane, 0.242%
2,4-Dimethylheptane, 0.058%
2,5-Dimethylheptane, 0.813%
3,3-Dimethylheptane, 0.355%
3,4-Dimethylheptane, 0.166%
3,5-Dimethylheptane, 0.463%
2,2-Dimethylhexane, 0.155%
2,3-Dimethylhexane, 0.041%
2,4-Dimethylhexane, 0.287%
2,5-Dimethylhexane, 1.156%
2,2-Dimethyloctane, 0.416%
2,5-Dimethyloctane, 0.004%
3,3-Dimethyloctane, 0.158%
2,2-Dimethylpentane, 0.623%
2,3-Dimethylpentane, 1.129%
2,4-Dimethylpentane, 1.356%
3,3-Dimethylpentane, 0.528%
2,2-Dimethylpropane, 0.02%
3-Ethylhexane, 0.103%
3-Ethyloctane, 0.211%
3-Ethylpentane, 0.374%
I9, 0.005%
I15, 0.004%
I20, 0.01%
I24, 0.003%
I45, 0.007%
Isobutane, 0.7%
Isopentane, 3.249%
2-Methylheptane, 1.286%
3-Methylheptane, 1.455%
4-Methylheptane, 0.411%
2-Methylhexane, 1.909%
3-Methylhexane, 1.36%
2-Methylnonane, 0.32%
3-Methylnonane, 1.047%
2-Methyloctane, 0.308%
3-Methyloctane, 1.432%
2-Methylpentane, 3.408%
3-Methylpentane, 3.369%
2,2,3-Trimethylbutane, 0.158%
2,2,3-Trimethylhexane, 0.064%
2,2,4-Trimethylhexane, 0.006%
2,2,3-Trimethylpentane, 0.825%
Olefins
1-Decene, 0.197%
1-Heptene, 0.59%
cis-2-Heptene, 0.297%
trans-2-Heptene, 0.046%
cis-3-Heptene, 0.088%
trans-3-Heptene, 0.326%
1-Hexene, 0.978%
cis-2-Hexene, 0.254%
trans-2-Hexene, 0.141%
cis-Hexene-3, 0.008%
trans-Hexene-3, 0.026%
2-Methyl-1,3-Butadiene, 0.32%
2-Methyl-1-Butene, 0.193%
3-Methyl-1-Butene, 0.133%
2-Methyl-1-Nonene, 0.297%
2-Methyl-2-Pentene, 0.299%
3-Methyl-t-Pentene-2, 0.009%
4-Methyl-1-Pentene, 0.295%
1-Nonene, 0.601%
trans-2-Nonene, 0.199%
cis-3-Nonene, 0.263%
trans-3-Nonene, 0.202%
cis-4-Nonene, 0.379%
1-Octene, 0.986%
cis-2-Octene, 0.201%
trans-2-Octene, 0.3%
1,4-Pentadiene, 0.004%
1-Pentene, 0.763%
cis-2-Pentene, 0.096%
trans-2-Pentene, 0.248%
Naphthenes
N-Butylcyclopentane, 0.008%
Cyclohexane, 1.422%
Cyclopentane, 0.532%
cis-1,2-Dimethylcyclohexane, 0.599%
trans-1,2-Dimethylcyclohexane, 0.152%
1c,3-Dimethylcyclohexane, 0.007%
1c,4-Dimethylcyclohexane, 0.003%
trans-1,4-Dimethylcyclohexane, 0.344%
1,1-Dimethylcyclopentane, 0.099%
trans-1,2-Dimethylcyclopentane, 0.43%
cis-1,3-Dimethylcyclopentane, 0.174%
trans-1,3-Dimethylcyclopentane, 0.326%
Ethylcyclopentane, 0.592%
1-Ethyl-1-Methylcyclopentane, 0.082%
2t-Ethylmethylcyclopentane, 0.036%
Isobutylcyclohexane, 0.207%
Isobutylcyclopentane, 0.075%
Isopropylcyclopentane, 0.076%
Methylcyclohexane, 1.968%
Methylcyclopentane, 1.238%
t-1-Methyl-2(4-Methylphenyl)cyclopentane, 0.203%
t-1-Methyl-2-N-Propylcyclohexane, 0.263%
N3, 0.004%
N14, 0.04%
N26, 0.007%
N29, 0.004%
N30, 0.008%
N37, 0.011%
N-Propylcyclopentane, 0.25%
1,1,2-Trimethylcyclohexane, 0.103%
1,1,4-Trimethylcyclohexane, 0.376%
ctc-1,2,3-Trimethylcyclohexane, 0.207%
ctc-1,2,4-Trimethylcyclohexane, 0.06%
ctt-1,2,4-Trimethylcyclohexane, 0.103%
ccc-1,3,5-Trimethylcyclohexane, 0.131%
1,1,2-Trimethylcyclopentane, 0.018%
1,1,3-Trimethylcyclopentane, 0.044%
ccc-1,2,3-Trimethylcyclopentane, 0.045%
ctc-1,2,3-Trimethylcyclopentane, 0.211%
tcc-1,2,3-Trimethylcyclopentane, 0.032%
ctc-1,2,4-Trimethylcyclopentane, 0.04%
Aromatics
Benzene, 1.752%
N-Butylbenzene, 0.349%
sec-Butylbenzene, 0.519%
tert-Butylbenzene, 0.345%
tert-1-Butyl-4-Ethylbenzene, 0.348%
tert-1-Butyl-2-Methylbenzene, 0.349%
tert-1-Butyl-3,4,5-Trimethylbenzene, 0.563%
1,4-Diethylbenzene, 0.005%
1,2-Dimethyl-3-Ethylbenzene, 0.361%
1,2-Dimethyl-4-Ethylbenzene, 0.153%
1,3-Dimethyl-2-Ethylbenzene, 0.134%
1,3-Dimethyl-5-Ethylbenzene, 0.068%
1,4-Dimethyl-2-Ethylbenzene, 0.348%
Ethylbenzene, 1.425%
Hexylbenzene, 0.865%
Isobutylbenzene, 0.52%
Isopropylbenzene, 0.353%
1,2-Di-isopropylbenzene, 0.012%
2-Methylbutylbenzene, 0.02%
1,4-Methyl-t-Butylbenzene, 0.004%
1-Methyl-2-Ethylbenzene, 0.264%
1-Methyl-3-Ethylbenzene, 0.48%
1-Methyl-4-Ethylbenzene, 0.357%
1-Methyl-2-Isopropylbenzene, 0.47%
1-Methyl-3-Isopropylbenzene, 0.179%
1-Methyl-4-Isopropylbenzene, 0.692%
1,4-Methyl-n-Pentylbenzene, 0.006%
1-Methyl-2-n-Propylbenzene, 0.36%
1-Methyl-3-n-Propylbenzene, 0.35%
1-Methyl-4-n-Propylbenzene, 0.348%
Pentylbenzene, 0.345%
N-Propylbenzene, 0.519%
1,2,4,5-Tetramethylbenzene, 0.144%
Toluene, 3.031%
1,2,4-Triethylbenzene, 0.171%
1,3,5-Triethylbenzene, 0.35%
1,2,4-Trimethylbenzene, 0.362%
1,3,5-Trimethylbenzene, 0.092%
m-Xylene, 0.756%
o-Xylene, 0.57%
p-Xylene, 0.248%
Oxygenates
tert-Butanol, 0.886%
Ethanol, 5.761%
Isopropanol, 0.048%
Methanol, 0.953%
Methyl Decanoate, 0.019%
MTBE, 0.476%
TAME, 1.332%

Specifications

Product Specifications
Catalog No.
30731
Product Name
DHA PONA Standard, Neat, 0.15 mL in Autosampler Vial