  1. PFAS 24 Calibration Standard, 1 µg/mL, Methanol (1 mM KOH), 1 mL/ampul

PFAS 24 Calibration Standard, 1 µg/mL, Methanol (1 mM KOH), 1 mL/ampul

Catalog No. 30733
$306.00
Shipping Note
Access your CofA online at www.restek.com/documentation
PFAS 24 Calibration Standard, 1 µg/mL, Methanol (1 mM KOH), 1 mL/ampul

PFAS 24 Calibration Standard, 1 µg/mL, Methanol (1 mM KOH), 1 mL/ampul

$306.00

Overview

Features & Benefits
  • 24-component mix simplifies calibration complexity, saving time and reducing cost.
  • Verified composition and stability ensure long-lasting shelf life.
  • Two independently produced lots available.
  • Ideal for the analysis of PFAS in water and other matrices.
  • Meets EPA 8327 method requirements.
Description

1H,1H,2H,2H-Perfluorodecane sulfonic acid (8:2 FTS) (39108-34-4)
1H,1H,2H,2H-Perfluorohexane sulfonic acid (4:2 FTS) (757124-72-4)
1H,1H,2H,2H-Perfluorooctane sulfonic acid (6:2 FTS) (27619-97-2)
N-ethylperfluoro-1-octanesulfonamidoacetic acid (NEtFOSAA) (2991-50-6)
N-methylperfluoro-1-octanesulfonamidoacetic acid (NMeFOSAA) (2355-31-9)
Perfluoro-1-decanesulfonic acid (PFDS) (335-77-3)
Perfluoro-1-nonanesulfonic acid (PFNS) (68259-12-1)
Perfluoro-1-octanesulfonamide (FOSA) (754-91-6)
Perfluoro-1-pentanesulfonic acid (PFPeS) (2706-91-4)
Perfluorobutanesulfonic acid (PFBS) (375-73-5)
Perfluorobutanoic acid (PFBA) (375-22-4)
Perfluorodecanoic acid (PFDA) (335-76-2)
Perfluorododecanoic acid (PFDOA) (307-55-1)
Perfluoroheptanesulfonic acid (PFHpS) (375-92-8)
Perfluoroheptanoic acid (PFHpA) (375-85-9)
Perfluorohexanesulfonic acid (PFHxS)* ( 355-46-4)
Perfluorohexanoic acid (PFHxA) (307-24-4)
Perfluorononanoic acid (PFNA) (375-95-1)
Heptadecafluorooctanesulfonic acid (PFOS)* (1763-23-1)
Perfluorooctanoic acid (PFOA)* (335-67-1)
Perfluoropentanoic acid (PFPeA) (2706-90-3)
Perfluorotetradecanoic acid (PFTeDA) (376-06-7)
Perfluorotridecanoic acid (PFTrDA) (72629-94-8)
Perfluoroundecanoic acid (PFUnA) (2058-94-8)

*Technical grade compound containing both branched and linear isomers; see certificate for details.

Specifications

Product Specifications
Catalog No.
30733
Product Name
PFAS 24 Calibration Standard, 1 µg/mL, Methanol (1 mM KOH), 1 mL/ampul