8270 Calibration Kit, 2000 µg/mL

8270 Calibration Kit, 2000 µg/mL
Overview
Contains 1 mL each of these mixtures.
31618: 8270 Calibration Mix #1
Benzoic acid (65-85-0)
4-Chloro-3-methylphenol (59-50-7)
2-Chlorophenol (95-57-8)
2,4-Dichlorophenol (120-83-2)
2,6-Dichlorophenol (87-65-0)
2,4-Dimethylphenol (105-67-9)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
Dinoseb (88-85-7)
2-Methylphenol (o-cresol) (95-48-7)
3-Methylphenol (m-cresol) (108-39-4)
4-Methylphenol (p-cresol) (106-44-5)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
Pentachlorophenol (87-86-5)
Phenol (108-95-2)
2,3,4,6-Tetrachlorophenol (58-90-2)
2,4,5-Trichlorophenol (95-95-4)
2,4,6-Trichlorophenol (88-06-2)
31619: 8270 Calibration Mix #2
Aniline (62-53-3)
Benzidine (92-87-5)
4-Chloroaniline (106-47-8)
3,3'-Dichlorobenzidine (91-94-1)
Diphenylamine (122-39-4)*
2-Nitroaniline (88-74-4)
3-Nitroaniline (99-09-2)
4-Nitroaniline (100-01-6)
N-Nitrosodimethylamine (62-75-9)
N-Nitroso-di-n-propylamine (621-64-7)
Pyridine (110-86-1)
31620: 8270 Calibration Mix #3
Aramite (140-57-8)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-chloroethoxy)methane (111-91-1)
4-Bromophenyl phenyl ether (101-55-3)
Chlorobenzilate (510-15-6)
2-Chloronaphthalene (91-58-7)
4-Chlorophenyl phenyl ether (7005-72-3)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
1,3-Dinitrobenzene (99-65-0)
Hexachlorobenzene (118-74-1)
Hexachlorobutadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)
Hexachloroethane (67-72-1)
Hexachloropropene (1888-71-7)
Isodrin (465-73-6)
Kepone (143-50-0)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorobenzene (608-93-5)
Pentachloronitrobenzene (Quintozene) (82-68-8)
1,2,4,5-Tetrachlorobenzene (95-94-3)
1,2,4-Trichlorobenzene (120-82-1)
31621: 8270 Calibration Mix #4
Acetophenone (98-86-2)
Azobenzene (103-33-3)†
Benzyl alcohol (100-51-6)
Bis(2-ethylhexyl)phthalate (117-81-7)
Benzyl butyl phthalate (85-68-7)
Dibenzofuran (132-64-9)
Diethylphthalate (84-66-2)
Dimethylphthalate (131-11-3)
Di-n-butyl phthalate (84-74-2)
Di-n-octyl phthalate (117-84-0)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Ethyl methanesulfonate (62-50-0)
Isophorone (78-59-1)
Isosafrole (cis & trans) (120-58-1)
Methyl methanesulfonate (66-27-3)
1,4-Naphthoquinone (130-15-4)
Nitrobenzene (98-95-3)
4-Nitroquinoline-N-oxide (56-57-5)
Phenacetin (62-44-2)
Safrole (94-59-7)
1,3,5-Trinitrobenzene (99-35-4)
31995: 8270 Calibration Mix #5, Revised
Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Anthracene (120-12-7)
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Indeno[1,2,3-cd]pyrene (193-39-5)
1-Methylnaphthalene (90-12-0)
2-Methylnaphthalene (91-57-6)
Naphthalene (91-20-3)
Phenanthrene (85-01-8)
Pyrene (129-00-0)
31996: 3-Methylcholanthrene Standard
3-Methylcholanthrene (56-49-5)
*N-Nitrosodiphenylamine is a reactive species that can initiate premature decomposition of other compounds in the mix. For these reasons, diphenylamine is used in the preparation of this mixture.
†1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.