Home / Reference Standards / Multi-Component / Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
Restek
Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
  1. Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul

Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul

Catalog No. 31829
$167.00
Shipping Note

Reference standards shipped after December 31, 2023, will no longer include paper hard copies of certificates of analysis (CofAs). Access your CofA online at www.restek.com/documentation

Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul

Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul

$167.00

Overview

Features & Benefits
  • MegaMix mixture includes all target compounds not in our current products.
  • Incorporates all phenols, for fast preparation and calibration.
  • Incorporates "additional" extractable Method 625 compounds.
Description

US EPA Method 625 is a GC-MS method applicable to analysis of organic compounds in water and soil. The sample is serially extracted with methylene chloride at pH >11, then at pH <2; the extract is dried, concentrated, and analyzed. We have offered numerous mixes for this method: phenols, benzidines, phthalate esters, polyaromatic hydrocarbons, chlorinated pesticides, isophorone, toxaphene, Aroclor PCBs. Our Semivolatiles MegaMix EPA Method 625 combines many of these analytes, including all the phenols, for faster and more convenient preparation. The mixture has been formulated carefully, to ensure maximum stability. For completeness, we also include target compounds listed as additional in Method 625.

Some of the target compounds in Method 625 are subject to thermal or chemical degradation and consequent unpredictable chromatographic performance. Hexachlorocyclopentadiene can decompose at the GC inlet. N-nitrosodimethylamine is difficult to separate from the Method 625 solvent; Method 625 suggests that the analyst follow Method 607 to identify this analyte. Some phenolic compounds in the target list, including chlorinated, methylated, and nitro-substituted phenols, are susceptible to adsorption and/or thermal degradation at the GC inlet. In addition, peak tailing can be a problem with phenols.

We implemented several steps to deal with these problems. We include diphenylamine, rather than N-nitrosodiphenylamine, in the MegaMix formulation because N-nitrosodiphenylamine decomposes to diphenylamine at the GC inlet.

Acenaphthene (83-32-9)
Acenaphthylene (208-96-8)
Anthracene (120-12-7)
Benz[a]anthracene (56-55-3)
Benzo[a]pyrene (50-32-8)
Benzo[b]fluoranthene (205-99-2)
Benzo[g,h,i]perylene (191-24-2)
Benzo[k]fluoranthene (207-08-9)
Benzyl butyl phthalate (85-68-7)
Bis(2-chloroethoxy)methane (111-91-1)
Bis(2-chloroethyl)ether (111-44-4)
Bis(2-ethylhexyl)phthalate (117-81-7)
4-Bromophenyl phenyl ether (101-55-3)
4-Chloro-3-methylphenol (59-50-7)
2-Chloronaphthalene (91-58-7)
2-Chlorophenol (95-57-8)
4-Chlorophenyl phenyl ether (7005-72-3)
Chrysene (218-01-9)
Dibenz[a,h]anthracene (53-70-3)
1,2-Dichlorobenzene (95-50-1)
1,3-Dichlorobenzene (541-73-1)
1,4-Dichlorobenzene (106-46-7)
2,4-Dichlorophenol (120-83-2)
Diethylphthalate (84-66-2)
2,4-Dimethylphenol (105-67-9)
Dimethylphthalate (131-11-3)
Di-n-butylphthalate (84-74-2)
4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
2,4-Dinitrophenol (51-28-5)
2,4-Dinitrotoluene (121-14-2)
2,6-Dinitrotoluene (606-20-2)
Di-n-octyl phthalate (117-84-0)
Diphenylamine (122-39-4)*
Fluoranthene (206-44-0)
Fluorene (86-73-7)
Hexachlorobenzene (118-74-1)
Hexachloro-1,3-butadiene (87-68-3)
Hexachlorocyclopentadiene (77-47-4)*
Hexachloroethane (67-72-1)
Indeno[1,2,3-cd]pyrene (193-39-5)
Isophorone (78-59-1)
Naphthalene (91-20-3)
Nitrobenzene (98-95-3)
2-Nitrophenol (88-75-5)
4-Nitrophenol (100-02-7)
N-Nitrosodimethylamine (62-75-9)*
N-Nitroso-di-n-propylamine (621-64-7)
2,2'-Oxybis(1-chloropropane) (108-60-1)
Pentachlorophenol (87-86-5)
Phenanthrene (85-01-8)
Phenol (108-95-2)
Pyrene (129-00-0)
1,2,4-Trichlorobenzene (120-82-1)
2,4,6-Trichlorophenol (88-06-2)

*Listed as an "additional compound" in Method 625 (listed compound N-nitrosodiphenylamine decomposes to MegaMix component diphenylamine). The six other "additional compounds" are components in other Restek reference mixes used for Method 625: benzidine is included in cat.# 31030; β-BHC, δ-BHC, endosulfan I, endosulfan II, endrin are in cat.# 32291 and cat.# 32415.

Specifications

Product Specifications
Catalog No.
31829
Product Name
Semivolatiles MegaMix Standard, EPA Method 625, 1000 ug/mL, Methylene Chloride, 1 mL/ampul
Can't find what you're looking for?
Custom Reference Standards

Looking for a custom reference standard? Use this form to request a custom quote.