




Restek
GC Multiresidue Pesticide Standards Kit

GC Multiresidue Pesticide Standards Kit
Overview
- Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.
- Comprehensive 203-compound kit covers food safety lists by the FDA, USDA, and other global governmental agencies; individual ampuls also sold separately.
- Formulated and grouped for maximum long-term stability*.
- Quantitatively tested to confirm composition; detailed support documentation provided.
- Optimized multiresidue pesticide method is offered free of charge; downloadable XLS file includes conditions and transition tables.
- Restek is your complete supplier for world-class GC-MS/MS multiresidue pesticide analysis: reference and internal standards, Rxi-5ms GC columns, Q-sep QuEChERS sample preparation, inlet liners, accessories, and more!
* Note: When combining a large number of compounds with different chemical functionalities, mix stability can be an issue. In formulating these standards, we extensively studied the 203 compounds involved, then grouped them into as few mixes as possible while still ensuring maximum long-term stability and reliability. For quantitative analysis, we recommend analyzing each mix separately to ensure accurate results for every compound.
Contains one ampul of each of the following.
Cat.# 32563: GC Multiresidue Pesticide Standard #1 (16 components)
Organophosphorus Compounds
100 µg/mL each in toluene, 1 mL/ampul
Azinphos ethyl (2642-71-9)
Azinphos methyl (86-50-0)
Chlorpyrifos (2921-88-2)
Chlorpyrifos methyl (5598-13-0)
Diazinon (333-41-5)
EPN (2104-64-5)
Fenitrothion (122-14-5)
Isazophos (42509-80-8)
Phosalone (2310-17-0)
Phosmet (732-11-6)
Pirimiphos ethyl (23505-41-1)
Pirimiphos methyl (29232-93-7)
Pyraclofos (89784-60-1)
Pyrazophos (13457-18-6)
Pyridaphenthion (119-12-0)
Quinalphos (13593-03-8)
Cat.# 32564: GC Multiresidue Pesticide Standard #2 (40 components)
Organochlorine Compounds
100 µg/mL each in toluene, 1 mL/ampul
Aldrin (309-00-2)
α-BHC (319-84-6)
β-BHC (319-85-7)
γ-BHC (Lindane) (58-89-9)
δ-BHC (319-86-8)
Chlorbenside (103-17-3)
cis-Chlordane (5103-71-9)
trans-Chlordane (5103-74-2)
Chlorfenson (Ovex) (80-33-1)
Chloroneb (2675-77-6)
2,4'-DDD (53-19-0)
4,4'-DDD (72-54-8)
2,4'-DDE (3424-82-6)
4,4'-DDE (72-55-9)
2,4'-DDT (789-02-6)
4,4'-DDT (50-29-3)
4,4'-Dichlorobenzophenone (90-98-2)
Dieldrin (60-57-1)
Endosulfan I (959-98-8)
Endosulfan II (33213-65-9)
Endosulfan ether (3369-52-6)
Endosulfan sulfate (1031-07-8)
Endrin (72-20-8)
Endrin aldehyde (7421-93-4)
Endrin ketone (53494-70-5)
Ethylan (Perthane) (72-56-0)
Fenson (80-38-6)
Heptachlor (76-44-8)
Heptachlor epoxide (isomer B) (1024-57-3)
Hexachlorobenzene (118-74-1)
Isodrin (465-73-6)
2,4'-Methoxychlor (30667-99-3)
4,4'-Methoxychlor olefin (2132-70-9)
Mirex (2385-85-5)
cis-Nonachlor (5103-73-1)
trans-Nonachlor (39765-80-5)
Pentachloroanisole (1825-21-4)
Pentachlorobenzene (608-93-5)
Pentachlorothioanisole (1825-19-0)
Tetradifon (116-29-0)
Cat.# 32565: GC Multiresidue Pesticide Standard #3 (25 components)
Organonitrogen Compounds
100 µg/mL each in toluene:acetonitrile (99:1), 1 mL/ampul
Benfluralin (1861-40-1)
Biphenyl (92-52-4)
Chlorothalonil (1897-45-6)
Dichlofluanid (1085-98-9)
Dichloran (99-30-9)
3,4-Dichloroaniline (95-76-1)
2,6-Dichlorobenzonitrile (Dichlobenil) (1194-65-6)
Diphenylamine (122-39-4)
Ethalfluralin (55283-68-6)
Fluchloralin (33245-39-5)
Isopropalin (33820-53-0)
Nitralin (4726-14-1)
Nitrofen (1836-75-5)
Oxyfluorfen (42874-03-3)
Pendimethalin (40487-42-1)
Pentachloroaniline (527-20-8)
Pentachlorobenzonitrile (20925-85-3)
Pentachloronitrobenzene (Quintozene) (82-68-8)
Prodiamine (29091-21-2)
Profluralin (26399-36-0)
2,3,5,6-Tetrachloroaniline (3481-20-7)
Tetrachloronitrobenzene (Tecnazene) (117-18-0)
THPI (Tetrahydrophthalimide) (1469-48-3)
Tolylfluanid (731-27-1)
Trifluralin (1582-09-8)
Cat.# 32566: GC Multiresidue Pesticide Standard #4 (28 components)
Organonitrogen Compounds
100 µg/mL each in toluene, 1 mL/ampul
Acetochlor (34256-82-1)
Alachlor (15972-60-8)
Allidochlor (93-71-0)
Clomazone (Command) (81777-89-1)
Cycloate (1134-23-2)
Diallate (cis & trans) (2303-16-4)
Dimethachlor (50563-36-5)
Diphenamid (957-51-7)
Fenpropathrin (39515-41-8)
Fluquinconazole (136426-54-5)
Flutolanil (66332-96-5)
Linuron (330-55-2)
Metazachlor (67129-08-2)
Methoxychlor (72-43-5)
Metolachlor (51218-45-2)
N-(2,4-Dimethylphenyl)formamide (60397-77-5)
Norflurazon (27314-13-2)
Oxadiazon (19666-30-9)
Pebulate (1114-71-2)
Pretilachlor (51218-49-6)
Prochloraz (67747-09-5)
Propachlor (1918-16-7)
Propanil (709-98-8)
Propisochlor (86763-47-5)
Propyzamide (23950-58-5)
Pyridaben (96489-71-3)
Tebufenpyrad (119168-77-3)
Triallate (2303-17-5)
Cat.# 32567: GC Multiresidue Pesticide Standard #5 (34 components)
Organonitrogen Compounds
100 µg/mL each in toluene, 1 mL/ampul
Atrazine (1912-24-9)
Bupirimate (41483-43-6)
Captafol (2425-06-1)
Captan (133-06-2)
Chlorfenapyr (122453-73-0)
Cyprodinil (121552-61-2)
Etofenprox (80844-07-1)
Etridiazole (2593-15-9)
Fenarimol (60168-88-9)
Fipronil (120068-37-3)
Fludioxonil (131341-86-1)
Fluridone (Sonar) (59756-60-4)
Flusilazole (85509-19-9)
Flutriafol (76674-21-0)
Folpet (133-07-3)
Hexazinone (Velpar) (51235-04-2)
Iprodione (36734-19-7)
Lenacil (2164-08-1)
MGK-264 (113-48-4)
Myclobutanil (88671-89-0)
Paclobutrazol (76738-62-0)
Penconazole (66246-88-6)
Procymidone (32809-16-8)
Propargite (2312-35-8)
Pyrimethanil (53112-28-0)
Pyriproxyfen (95737-68-1)
Tebuconazole (107534-96-3)
Terbacil (5902-51-2)
Terbuthylazine (5915-41-3)
Triadimefon (43121-43-3)
Triadimenol (55219-65-3)
Tricyclazole (Beam) (41814-78-2)
Triflumizole (68694-11-1)
Vinclozolin (50471-44-8)
Cat.# 32568: GC Multiresidue Pesticide Standard #6 (18 components)
Synthetic Pyrethroid Compounds
100 µg/mL each in toluene, 1 mL/ampul
Acrinathrin (101007-06-1)
Anthraquinone (84-65-1)
Bifenthrin (82657-04-3)
Bioallethrin (584-79-2)
Cyfluthrin (68359-37-5)
lambda-Cyhalothrin (91465-08-6)
Cypermethrin (52315-07-8)
Deltamethrin (52918-63-5)
Fenvalerate (51630-58-1)
Flucythrinate (70124-77-5)
tau-Fluvalinate (102851-06-9)
cis-Permethrin (61949-76-6)
trans-Permethrin (61949-77-7)
Phenothrin (cis & trans) (26002-80-2)
Resmethrin (10453-86-8)
Tefluthrin (79538-32-2)
Tetramethrin (7696-12-0)
Transfluthrin (118712-89-3)
Cat.# 32569: GC Multiresidue Pesticide Standard #7 (10 components)
Herbicide Methyl Esters
100 µg/mL each in toluene, 1 mL/ampul
Acequinocyl (57960-19-7)
Bromopropylate (18181-80-1)
Carfentrazone ethyl (128639-02-1)
Chlorobenzilate (510-15-6)
Chlorpropham (101-21-3)
Chlozolinate (84332-86-5)
DCPA methyl ester (Chlorthal-dimethyl) (1861-32-1)
Fluazifop-p-butyl (79241-46-6)
Metalaxyl (57837-19-1)
2-Phenylphenol (90-43-7)
Cat.# 32570: GC Multiresidue Pesticide Standard #8 (24 components)
Organophosphorus Compounds
100 µg/mL each in toluene, 1 mL/ampul
Bromfenvinfos-methyl (13104-21-7)
Bromfenvinphos (33399-00-7)
Bromophos ethyl (4824-78-6)
Bromophos methyl (2104-96-3)
Carbophenothion (786-19-6)
Chlorfenvinphos (470-90-6)
Chlorthiophos (60238-56-4)
Coumaphos (56-72-4)
Edifenphos (17109-49-8)
Ethion (563-12-2)
Fenamiphos (22224-92-6)
Fenchlorphos (Ronnel) (299-84-3)
Fenthion (55-38-9)
Iodofenphos (18181-70-9)
Leptophos (21609-90-5)
Malathion (121-75-5)
Methacrifos (62610-77-9)
Profenofos (41198-08-7)
Prothiofos (34643-46-4)
Sulfotepp (3689-24-5)
Sulprofos (35400-43-2)
Terbufos (13071-79-9)
Tetrachlorvinphos (22248-79-9)
Tolclofos-methyl (57018-04-9)
Cat.# 32571: GC Multiresidue Pesticide Standard #9 (8 components)
Organophosphorus Compounds
100 µg/mL each in toluene, 1 mL/ampul
Disulfoton (298-04-4)
Fonofos (944-22-9)
Methyl parathion (298-00-0)
Mevinphos (7786-34-7)
Parathion (ethyl parathion) (56-38-2)
Phorate (298-02-2)
Piperonyl butoxide (51-03-6)
Triazophos (24017-47-8)