Restek
Home / Reference Standards / Multi-Component / Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit
Restek
Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit
  1. Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit

Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit

Catalog No. 32592
$613.00
Shipping Note
Reference standards shipped after December 31, 2023, will no longer include paper hard copies of certificates of analysis (CofAs). Access your CofA online at www.restek.com/documentation
Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit

Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit

$613.00

Overview

Features & Benefits
  • Convenient, 96-compound kit contains only the compounds required by Canadian cannabis regulations, saving time and reducing cost.
  • Two independently produced lots available.
  • Verified composition and stability ensures long-lasting shelf life.
  • Can be used to meet other government or in-house method requirements.
Description

Contains 1 ampul of each of the following. 100 μg/mL, Acetonitrile, 1 mL/ampul

 

Cat.# 32593: Canadian Pesticide Standard #1

Compound CAS#
Aldicarb 116-06-3
Bifenazate 149877-41-8
Carbaryl (Sevin) 63-25-2
Carbofuran 1563-66-2
Fenoxycarb 72490-01-8
Iprodione 36734-19-7
Methiocarb 2032-65-7
Methomyl 16752-77-5
Novaluron 116714-46-6
Oxamyl 23135-22-0
Pirimicarb 23103-98-2
Propoxur (Baygon) 114-26-1
Pyraclostrobin 175013-18-0
Teflubenzuron 83121-18-0
Thiophanate-methyl 23564-05-8

 

Cat.# 32594: Canadian Pesticide Standard #2

Compound CAS#
Acephate 30560-19-1
Chlorpyrifos 2921-88-2
Coumaphos 56-72-4
Diazinon 333-41-5
Dimethoate 60-51-5
Ethoprophos 13194-48-4
Fensulfothion 115-90-2
Fenthion 55-38-9
Malathion 121-75-5
Methyl parathion 298-00-0
Mevinphos 7786-34-7
Naled 300-76-5
Phosmet 732-11-6
Tetrachlorvinphos 22248-79-9

 

Cat.# 32595: Canadian Pesticide Standard #3

Compound CAS#
Abamectin 71751-41-2
Allethrin 584-79-2
Bifenthrin 82657-04-3
Cyfluthrin 68359-37-5
Cypermethrin 52315-07-8
Deltamethrin 52918-63-5
Etofenprox 80844-07-1
Fenvalerate 51630-58-1
Permethrin (cis & trans) 52645-53-1
Phenothrin (cis & trans) 26002-80-2
Prallethrin 23031-36-9
Pyrethrins* 8003-34-7
Resmethrin 10453-86-8
Spinetoram (J&L) 935545-74-7
Spinosad (A&D) 168316-95-8
Spirodiclofen 148477-71-8
Spiromesifen 283594-90-1
Tetramethrin 7696-12-0

 

Cat.# 32596: Canadian Pesticide Standard #4

Compound CAS#
Azoxystrobin 131860-33-8
Chlorfenapyr 122453-73-0
Clofentezine 74115-24-5
Cyprodinil 121552-61-2
Daminozide** 1596-84-5
Etoxazole 153233-91-1
Etridiazole 2593-15-9
(E)-Fenpyroximate 134098-61-6
Fipronil 120068-37-3
Fludioxonil 131341-86-1
Imazalil 35554-44-0
Myclobutanil 88671-89-0
Paclobutrazol 76738-62-0
Propiconazole (Tilt) 60207-90-1
Pyridaben 96489-71-3
Tebuconazole 107534-96-3

 

Cat.# 32597: Canadian Pesticide Standard #5

Compound CAS#
Benzovindiflupyr 1072957-71-1
Boscalid 188425-85-6
Buprofezin 69327-76-0
Chlorantraniliprole** 500008-45-7
Clothianidin 210880-92-5
Cyantraniliprole 736994-63-1
Dimethomorph 110488-70-5
Dinotefuran 165252-70-0
Flonicamid 158062-67-0
Fluopyram 658066-35-4
Hexythiazox 78587-05-0
Imidacloprid 138261-41-3
Metalaxyl 57837-19-1
Pentachloronitrobenzene 82-68-8
Spirotetramat 203313-25-1
Tebufenozide 112410-23-8
Thiamethoxam 153719-23-4

 

Cat.# 32598: Canadian Pesticide Standard #6

Compound CAS#
Acequinocyl 57960-19-7
Acetamiprid 135410-20-7
Dodemorph 1593-77-7
Endosulfan I 959-98-8
Endosulfan II 33213-65-9
Endosulfan sulfate 1031-07-8
Kinoprene 42588-37-4
Kresoxim methyl 143390-89-0
Methoprene 40596-69-8
MGK-264 113-48-4
Piperonyl butoxide 51-03-6
Spiroxamine 118134-30-8
Thiacloprid 111988-49-9
Trifloxystrobin 141517-21-7

 

Cat.# 32599: Azadirachtin Standard

Compound CAS#
Azadirachtin 11141-17-6

 

Cat.# 32585: Dichlorvos Standard

Compound CAS#
Dichlorvos (DDVP) 62-73-7

 

*This reference material contains pyrethrins, a technical mixture that is composed of six active insecticidal compounds. The ratio of each of the six compounds in this specific mixture is provided in the order they have eluted under the run conditions listed on the certificate. Only the peak corresponding to the pyrethrin compound with the highest signal intensity is labeled on the chromatogram. Due to the nature of pyrethrins, lot-to-lot variation in composition and purity may be observed based on raw material source.

This reference material contains both the Spinetoram J and L isomers (187166-40-1 and 187166-15-0); however, CAS# 935545-74-7 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 935545-74-7 is a blend of Spinetoram J and L, and the ratio of each material isomer is displayed on your certificate of analysis.

This reference material contains Spinosad A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of Spinosad A and D, and the ratio of each material isomer is displayed on your certificate of analysis.

**Reference materials containing chlorantraniliprole (500008-45-7) and daminozide (1596-84-5) must be sonicated for a minimum of 60 minutes prior to opening the ampul. Because each ultrasonic bath operates at a different energy level, 60 minutes is a guideline only. Longer sonication time will not affect product quality. These precautions apply to working solutions prepared in your laboratory as well. The amount of compound that precipitates depends on concentration and temperature. If you store your standards, even dilute solutions, at a temperature well below the label recommendation, allow extra sonication time.

Specifications

Product Specifications
Catalog No.
32592
Product Name
Canadian Pesticide Standards Kit, 1 mL/ampul; 8 ampuls/kit
Can't find what you're looking for?
Custom Reference Standards

Looking for a custom reference standard? Use this form to request a custom quote.