Restek
Home / Reference Standards / Multi-Component / Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
Restek
Featured
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
  1. Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

Catalog No. 32600
$405.00
Shipping Note
Reference standards shipped after December 31, 2023, will no longer include paper hard copies of certificates of analysis (CofAs). Access your CofA online at www.restek.com/documentation
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit

$405.00

Overview

Features & Benefits
  • 58-component kit provides analytical flexibility for constructing calibration curves or spiking sample matrices—saving time and reducing cost.
  • The standard concentration of each mix is 400 times the action limit—100 times when all four mixes are combined.
  • Two independently produced lots available.
  • Verified composition and stability ensures long-lasting shelf life.
  • Formulated for Arizona cannabis regulations; can be used to meet other government or in-house method requirements.
Description

Contains 1 ampul of each of the following. 1 mL/ampul

 

Cat.# 32601: Arizona Pesticide Standard #1

Compound CAS# Concentration
Acephate 30560-19-1 160 µg/mL
Aldicarb 116-06-3 160 µg/mL
Bifenazate 149877-41-8 80 µg/mL
Carbaryl (Sevin) 63-25-2 80 µg/mL
Carbofuran 1563-66-2 80 µg/mL
Chlorpyrifos 2921-88-2 80 µg/mL
Dichlorvos 62-73-7 40 µg/mL
Diazinon 333-41-5 80 µg/mL
Dimethoate 60-51-5 80 µg/mL
Ethoprophos 13194-48-4 80 µg/mL
Fenoxycarb 72490-01-8 80 µg/mL
Malathion 121-75-5 80 µg/mL
Methiocarb 2032-65-7 80 µg/mL
Methomyl 16752-77-5 160 µg/mL
Naled 300-76-5 200 µg/mL
Oxamyl 23135-22-0 400 µg/mL
Phosmet 732-11-6 80 µg/mL
Propoxur 114-26-1 80 µg/mL

 

Cat.# 32602: Arizona Pesticide Standard #2

Compound CAS# Concentration
Abamectin 71751-41-2 200 µg/mL
Acequinocyl 57960-19-7 800 µg/mL
Bifenthrin 82657-04-3 80 µg/mL
Cyfluthrin 68359-37-5 400 µg/mL
Cypermethrin 52315-07-8 400 µg/mL
Etofenprox 80844-07-1 160 µg/mL
Permethrin (cis & trans) 52645-53-1 80 µg/mL
Prallethrin 23031-36-9 80 µg/mL
Pyrethrins* 8003-34-7 400 µg/mL
Spinosad (A&D) 168316-95-8 80 µg/mL

 

Cat.# 32603: Arizona Pesticide Standard #3

Compound CAS# Concentration
Acetamiprid 135410-20-7 80 µg/mL
Clofentezine 74115-24-5 80 µg/mL
Etoxazole 153233-91-1 80 µg/mL
Fipronil 120068-37-3 160 µg/mL
Fludioxonil 131341-86-1 160 µg/mL
Imazalil 35554-44-0 80 µg/mL
Imidacloprid 138261-41-3 160 µg/mL
Myclobutanil 88671-89-0 80 µg/mL
Paclobutrazol 76738-62-0 160 µg/mL
Pendimethalin 40487-42-1 40 µg/mL
Propiconazole (Tilt) 60207-90-1 160 µg/mL
Tebuconazole 107534-96-3 160 µg/mL
Thiacloprid 111988-49-9 80 µg/mL
Thiamethoxam 153719-23-4 80 µg/mL

 

Cat.# 32604: Arizona Pesticide Standard #4

Compound CAS# Concentration
Azoxystrobin 131860-33-8 80 µg/mL
Boscalid 188425-85-6 160 µg/mL
Chlorantraniliprole 500008-45-7 80 µg/mL
Chlorfenapyr 122453-73-0 400 µg/mL
Daminozide 1596-84-5 400 µg/mL
(E)-Fenpyroximate 134098-61-6 160 µg/mL
Flonicamid 158062-67-0 400 µg/mL
Hexythiazox 78587-05-0 400 µg/mL
Kresoxim methyl 143390-89-0 160 µg/mL
Metalaxyl 57837-19-1 80 µg/mL
Piperonyl butoxide 51-03-6 800 µg/mL
Pyridaben 96489-71-3 80 µg/mL
Spiromesifen 283594-90-1 80 µg/mL
Spirotetramat 203313-25-1 80 µg/mL
Spiroxamine 118134-30-8 160 µg/mL
Trifloxystrobin 141517-21-7 80 µg/mL

 

*This reference material contains pyrethrins, a technical mixture that is composed of six active insecticidal compounds. The ratio of each of the six compounds in this specific mixture is provided in the order they have eluted under the run conditions listed on the certificate. Only the peak corresponding to the pyrethrin compound with the highest signal intensity is labeled on the chromatogram. Due to the nature of pyrethrins, lot-to-lot variation in composition and purity may be observed based on raw material source.

This reference material contains Spinosad A and D isomers (131929-60-7 and 131929-63-0); however, CAS# 168316-95-8 is displayed on the certificate as this is the neat material dissolved in the solution. CAS# 168316-95-8 is a blend of Spinosad A and D, and the ratio of each material isomer is displayed on your certificate of analysis.

Reference materials containing chlorantraniliprole (500008-45-7) and daminozide (1596-84-5) must be sonicated for a minimum of 60 minutes prior to opening the ampul. Because each ultrasonic bath operates at a different energy level, 60 minutes is a guideline only. Longer sonication time will not affect product quality. These precautions apply to working solutions prepared in your laboratory as well. The amount of compound that precipitates depends on concentration and temperature. If you store your standards, even dilute solutions, at a temperature well below the label recommendation, allow extra sonication time.

Specifications

Product Specifications
Catalog No.
32600
Product Name
Arizona Pesticide Kit, 1 mL/ampul, 4 ampuls/kit
Can't find what you're looking for?
Custom Reference Standards

Looking for a custom reference standard? Use this form to request a custom quote.