Peaks | tR (min) | |
---|---|---|
1. | Propylene | 1.42 |
2. | Dichlorodifluoromethane (Freon 12) | 1.46 |
3. | 1,2-Dichlorotetrafluoroethane (Freon 114) | 1.60 |
4. | Chloromethane | 1.63 |
5. | Vinyl chloride | 1.72 |
6. | 1,3-Butadiene | 1.75 |
7. | Bromomethane | 2.01 |
8. | Chloroethane | 2.13 |
9. | Trichlorofluoromethane (Freon 11) | 2.26 |
10. | 1,1-Dichloroethene | 2.67 |
11. | Carbon disulfide | 2.68 |
12. | Ethanol | 2.70 |
13. | 1,1,2-Trichlorotrifluoroethane (Freon 113) | 2.72 |
14. | Acrolein | 2.96 |
15. | Isopropyl alcohol | 3.14 |
16. | Methylene chloride | 3.14 |
17. | Acetone | 3.19 |
18. | trans-1,2-Dichloroethene | 3.26 |
19. | Hexane | 3.33 |
20. | Methyl tert-butyl ether (MTBE) | 3.37 |
21. | Acetonitrile (contaminant) | 3.57 |
22. | 1,1-Dichloroethane | 3.75 |
23. | Vinyl acetate | 3.97 |
Peaks | tR (min) | |
---|---|---|
24. | cis-1,2-Dichloroethene | 4.18 |
25. | Cyclohexane | 4.33 |
26. | Bromochloromethane (IS) | 4.34 |
27. | Chloroform | 4.40 |
28. | Carbon tetrachloride | 4.50 |
29. | Ethyl acetate | 4.52 |
30. | Tetrahydrofuran | 4.53 |
31. | 1,1,1-Trichloroethane | 4.56 |
32. | 2-Butanone (MEK) | 4.66 |
33. | Heptane | 4.84 |
34. | Benzene | 4.87 |
35. | 1,2-Dichloroethane | 5.04 |
36. | Trichloroethylene | 5.36 |
37. | 1,4-Difluorobenzene (IS) | 5.40 |
38. | 1,2-Dichloropropane | 5.83 |
39. | Bromodichloromethane | 5.89 |
40. | Methyl methacrylate | 6.05 |
41. | 1,4-Dioxane | 6.11 |
42. | cis-1,3-Dichloropropene | 6.48 |
43. | Toluene | 6.70 |
44. | Tetrachloroethene | 7.07 |
45. | 4-Methyl-2-pentanone (MIBK) | 7.10 |
46. | trans-1,3-Dichloropropene | 7.13 |
Peaks | tR (min) | |
---|---|---|
47. | 1,1,2-Trichloroethane | 7.29 |
48. | Dibromochloromethane | 7.46 |
49. | 1,2-Dibromoethane | 7.70 |
50. | 2-Hexanone (MBK) | 7.98 |
51. | Chlorobenzene-d5 (IS) | 8.25 |
52. | Chlorobenzene | 8.27 |
53. | Ethylbenzene | 8.31 |
54. | m-Xylene | 8.48 |
55. | p-Xylene | 8.48 |
56. | o-Xylene | 8.96 |
57. | Styrene | 9.02 |
58. | Bromoform | 9.03 |
59. | 4-Bromofluorobenzene* | 9.65 |
60. | 1,1,2,2-Tetrachloroethane | 9.92 |
61. | 4-Ethyltoluene | 9.96 |
62. | 1,3,5-Trimethylbenzene | 10.08 |
63. | 1,2,4-Trimethylbenzene | 10.55 |
64. | 1,3-Dichlorobenzene | 10.92 |
65. | 1,4-Dichlorobenzene | 11.04 |
66. | Benzyl chloride | 11.37 |
67. | 1,2-Dichlorobenzene | 11.57 |
68. | Hexachlorobutadiene | 13.14 |
69. | 1,2,4-Trichlorobenzene | 13.15 |
70. | Naphthalene | 13.42 |
Column | Rtx-VMS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 19919) |
---|---|
Standard/Sample | TO-15 65 component mix (cat.# 34436) |
TO-14A internal standard/tuning mix (cat.# 34408) | |
Diluent: | Nitrogen |
Conc.: | 10.0 ppbv 200 cc injection |
Injection | Direct |
Oven | |
Oven Temp.: | 32 °C (hold 1 min) to 150 °C at 11 °C/min (hold 0 min) to 230 °C at 33 °C/min (hold 0 min) |
Carrier Gas | He, constant flow |
Flow Rate: | 2.0 mL/min |
Linear Velocity: | 51 cm/sec @ 32 °C |
Detector | MS | ||||||||
---|---|---|---|---|---|---|---|---|---|
Mode: | Scan | ||||||||
Scan Program: | |||||||||
| |||||||||
Transfer Line Temp.: | 230 °C | ||||||||
Analyzer Type: | Quadrupole | ||||||||
Source Temp.: | 230 °C | ||||||||
Quad Temp.: | 150 °C | ||||||||
Electron Energy: | 69.9 eV | ||||||||
Solvent Delay Time: | 1.0 min | ||||||||
Tune Type: | BFB | ||||||||
Ionization Mode: | EI | ||||||||
Preconcentrator | Nutech 8900DS | ||||||||
Trap 1 Settings | |||||||||
Type/Sorbent : | Glass beads | ||||||||
Cooling temp: | -155 °C | ||||||||
Preheat temp: | 5 °C | ||||||||
Preheat time: | 0 sec | ||||||||
Desorb temp: | 20 °C | ||||||||
Desorb flow: | 5 mL/min | ||||||||
Desorb time: | 360 sec | ||||||||
Bakeout temp: | 200 °C | ||||||||
Flush flow: | 120 mL/min | ||||||||
Flush time: | 60 sec | ||||||||
Sweep flow: | 120 mL/min | ||||||||
Sweep time: | 60 sec | ||||||||
Trap 2 Settings | |||||||||
Type/Sorbent: | Tenax | ||||||||
Cooling temp: | -35 °C | ||||||||
Desorb temp: | 190 °C | ||||||||
Desorb time: | 30 sec | ||||||||
Bakeout temp: | 200 °C | ||||||||
Bakeout time: | 10 sec | ||||||||
Cryofocuser | |||||||||
Cooling temp: | -160 °C | ||||||||
Inject time: | 140 sec | ||||||||
Internal Standard | |||||||||
Purge flow: | 100 mL/min | ||||||||
Purge time: | 6 sec | ||||||||
Vol.: | 20 mL | ||||||||
ISTD flow: | 100 mL/min | ||||||||
Standard | |||||||||
Size: | 200 mL | ||||||||
Purge flow: | 100 mL/min | ||||||||
Purge time: | 6 sec | ||||||||
Sample flow: | 100 mL/min | ||||||||
Instrument | HP6890 GC & 5973 MSD | ||||||||
Acknowledgement | Nutech |