Peaks | tR (min) | Match Quality | Vapor | Blank* | Region | |
---|---|---|---|---|---|---|
1. | Nitrogen/oxygen | 0.685 | 100 | x | x | Red |
2. | Carbon dioxide | 1.063 | 100 | x | x | Red |
3. | Propene | 1.200 | 100 | x | Red | |
4. | Formaldehyde | 1.227 | 100 | x | Red | |
5. | Sulfur dioxide | 1.313 | 90 | x | Red | |
6. | Chloromethane | 1.380 | 100 | x | Red | |
7. | Water | 1.453 | 100 | x | x | Red |
8. | Acetaldehyde | 1.672 | 100 | x | Red | |
9. | Methanol | 1.715 | 100 | x | x | Red |
10. | Unidentified | 1.885 | x | Red | ||
11. | Ethanol | 2.270 | 100 | x | Red | |
12. | Unidentified | 2.331 | x | Red | ||
13. | Unidentified | 2.410 | x | Red | ||
14. | Acrolein | 2.581 | 100 | x | Red | |
15. | Propanal | 2.629 | 100 | x | Red | |
16. | Methylene chloride | 2.770 | 100 | x | x | Red |
17. | Acetone | 2.843 | 100 | x | Red | |
18. | Unidentified | 2.892 | x | Red | ||
19. | Hexane | 2.928 | 100 | x | Red | |
20. | Acetonitrile | 3.160 | 100 | x | x | Red |
21. | Unidentified | 3.544 | x | Orange | ||
22. | Unidentified | 3.842 | x | Orange | ||
23. | Trimethylsilanol | 3.928 | 100 | x | Orange | |
24. | Unidentified | 4.092 | x | Orange | ||
25. | Unidentified | 4.159 | x | Orange | ||
26. | Unidentified | 4.245 | x | Orange | ||
27. | Unidentified | 4.354 | x | Orange | ||
28. | Benzene | 4.452 | 100 | x | x | Orange |
29. | Unidentified | 4.519 | x | Orange | ||
30. | Acetic acid | 5.055 | 86 | x | Orange | |
31. | Unidentified | 5.141 | x | Orange | ||
32. | Unidentified | 5.647 | x | Orange | ||
33. | Unidentified | 5.756 | x | Orange | ||
34. | 1-Hydroxy-2-propanone | 6.073 | 80 | x | Orange | |
35. | Unidentified | 6.165 | x | Orange | ||
36. | Unidentified | 6.220 | x | Orange | ||
37. | Toluene | 6.280 | 100 | x | x | Orange |
38. | Hexamethylcyclotrisiloxane | 6.506 | 91 | x | Orange | |
39. | Unidentified | 7.231 | x | Orange | ||
40. | Unidentified | 7.530 | x | Orange | ||
41. | Propylene glycol | 7.737 | 100 | x | Green | |
42. | m-Xylene | 8.048 | 100 | x | Green | |
43. | p-Xylene | 8.048 | 100 | x | Green | |
44. | o-Xylene | 8.530 | 100 | x | Green | |
45. | Styrene | 8.597 | 100 | x | Green | |
46. | Unidentified | 9.158 | x | Green | ||
47. | Octamethylcyclotetrasiloxane | 9.218 | 91 | x | Green | |
48. | 4-Methyl-1-(1-methylethyl)cyclohexene | 9.371 | 95 | x | Green | |
49. | Unidentified | 9.639 | x | Green | ||
50. | Unidentified | 9.852 | x | Green | ||
51. | Unidentified | 9.932 | x | Green | ||
52. | Unidentified | 10.121 | x | Green | ||
53. | Unidentified | 10.219 | x | Green | ||
54. | Trimethylpyrazine | 10.468 | 80 | x | Green | |
55. | Benzaldehyde | 10.657 | 100 | x | Green | |
56. | Unidentified | 10.858 | x | Green | ||
57. | Unidentified | 11.120 | x | Green | ||
58. | Unidentified | 11.187 | x | Green | ||
59. | Acetylpyrazine | 11.541 | 93 | x | Green | |
60. | Decamethylcyclopentasiloxane | 11.620 | 91 | x | Green | |
61. | Phenol | 11.870 | 94 | x | Green | |
62. | Unidentified | 12.272 | x | Green | ||
63. | 1,1'-Oxybis-2-propanol | 12.333 | 90 | x | Green | |
64. | Glycerin | 12.748 | 100 | x | Blue | |
65. | Unidentified | 13.327 | x | Blue | ||
66. | Dodecamethylcyclohexasiloxane | 13.979 | 94 | x | Blue | |
67. | Nicotine | 15.862 | 100 | x | Blue | |
68. | Tetradecamethylhexasiloxane | 16.082 | 91 | x | Blue | |
69. | Unidentified | 16.326 | x | Blue | ||
70. | Unidentified | 16.460 | x | Blue | ||
71. | Myosmine | 17.216 | 94 | x | Blue | |
72. | Nicotyrine | 17.807 | 90 | x | Blue | |
73. | Unidentified | 18.002 | x | Blue | ||
74. | 2,3'-Dipyridyl | 18.618 | 94 | x | Blue | |
75. | Unidentified | 18.721 | x | Blue | ||
76. | Unidentified | 19.294 | x | Blue | ||
77. | Unidentified | 19.611 | x | Blue | ||
78. | Unidentified | 20.093 | x | Blue | ||
79. | Unidentified | 20.190 | x | Blue | ||
80. | Unidentified | 20.269 | x | Blue | ||
81. | Unidentified | 20.501 | x | Blue | ||
82. | Unidentified | 20.855 | x | Blue |
Column | Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915) |
---|---|
Standard/Sample | |
Conc.: | One 40 mL puff of electronic cigarette vapor drawn via a gas-tight syringe to replicate vaping |
Injection | Direct |
Oven | |
Oven Temp.: | 35 °C (hold 1 min) to 250 °C at 11 °C/min (hold 4 min) |
Carrier Gas | He, constant flow |
Flow Rate: | 2.0 mL/min @ 35 °C |
Detector | MS | ||||||||
---|---|---|---|---|---|---|---|---|---|
Mode: | Scan | ||||||||
Scan Program: | |||||||||
| |||||||||
Transfer Line Temp.: | 250 °C | ||||||||
Analyzer Type: | Quadrupole | ||||||||
Source Type: | Extractor | ||||||||
Extractor Lens: | 6mm ID | ||||||||
Source Temp.: | 230 °C | ||||||||
Quad Temp.: | 150 °C | ||||||||
Electron Energy: | 70 eV | ||||||||
Tune Type: | BFB | ||||||||
Ionization Mode: | EI | ||||||||
Preconcentrator | Markes UNITY™ | ||||||||
Instrument | Agilent 7890B GC & 5977A MSD | ||||||||
Acknowledgement | Markes |