Peaks | tR (min) | |
---|---|---|
1. | 2-Fluorophenol (SS) | 4.65 |
2. | Phenol-d6 (SS) | 5.53 |
3. | Phenol | 5.55 |
4. | Bis(2-chloroethyl) ether | 5.64 |
5. | 2-Chlorophenol-d4 (SS) | 5.66 |
6. | 2-Chlorophenol | 5.67 |
7. | 1,3-Dichlorobenzene | 5.81 |
8. | 1,4-Dichlorobenzene-d4 (IS) | 5.86 |
9. | 1,4-Dichlorobenzene | 5.87 |
10. | 1,2-Dichlorobenzene-d4 (IS) | 6.01 |
11. | Benzyl alcohol | 6.01 |
12. | 1,2-Dichlorobenzene | 6.03 |
13. | 2-Methylphenol | 6.10 |
14. | Bis(2-chloroisopropyl) ether | 6.13 |
15. | 4-Methylphenol/3-Methylphenol | 6.25 |
16. | N-Nitrosodi-N-propylamine | 6.28 |
17. | Hexachloroethane | 6.33 |
18. | Nitrobenzene-d5 (SS) | 6.41 |
19. | Nitrobenzene | 6.43 |
20. | Isophorone | 6.66 |
21. | 2-Nitrophenol | 6.73 |
22. | 2,4-Dimethylphenol | 6.75 |
23. | Bis(2-chloroethoxy)methane | 6.85 |
24. | Benzoic acid | 6.91 |
25. | 2,4-Dichlorophenol | 6.95 |
26. | 1,2,4-Trichlorobenzene | 7.03 |
Peaks | tR (min) | |
---|---|---|
27. | Naphthalene-d8 (IS) | 7.08 |
28. | Naphthalene | 7.10 |
29. | 4-Chloroaniline | 7.20 |
30. | Hexachlorobutadiene | 7.21 |
31. | 4-Chloro-3-methylphenol | 7.62 |
32. | 2-Methylnaphthalene | 7.77 |
33. | Hexachlorocyclopentadiene | 7.92 |
34. | 2,4,6-Trichlorophenol | 8.05 |
35. | 2,4,5-Trichlorophenol | 8.08 |
36. | 2-Fluorobiphenyl (SS) | 8.13 |
37. | 2-Chloronaphthalene | 8.25 |
38. | 2-Nitroaniline | 8.38 |
39. | Dimethyl phthalate | 8.54 |
40. | 2,6-Dinitrotoluene | 8.62 |
41. | Acenaphthylene | 8.66 |
42. | Acenaphthene-d10 (IS) | 8.79 |
43. | Acenaphthene | 8.83 |
44. | 3-Nitroaniline | 8.88 |
45. | 2,4-Dinitrophenol | 8.88 |
46. | 4-Nitrophenol | 8.92 |
47. | Dibenzofuran | 8.99 |
48. | 2,4-Dinitrotoluene | 9.01 |
49. | Diethyl phthalate | 9.22 |
50. | 4-Chlorophenyl phenyl ether | 9.32 |
51. | Fluorene | 9.33 |
52. | 4-Nitroaniline | 9.39 |
Peaks | tR (min) | |
---|---|---|
53. | 2-Methyl-4,6-dinitrophenol | 9.40 |
54. | Diphenylamine | 9.44 |
55. | 2,4,6-Tribromophenol (SS) | 9.57 |
56. | 4-Bromophenyl phenyl ether | 9.80 |
57. | Hexachlorobenzene | 9.88 |
58. | Pentachlorophenol | 10.07 |
59. | Phenanthrene-d10 (IS) | 10.24 |
60. | Phenanthrene | 10.27 |
61. | Anthracene | 10.32 |
62. | Carbazole | 10.49 |
63. | di-n-Butyl phthalate | 10.84 |
64. | Fluoranthene | 11.62 |
65. | Pyrene | 11.94 |
66. | p-Terphenyl-d14 (SS) | 12.16 |
67. | Butyl benzyl phthalate | 13.01 |
68. | Benzo[a]anthracene | 14.05 |
69. | 3,3'-Dichlorobenzidine | 14.06 |
70. | Chrysene-d12 (IS) | 14.08 |
71. | Chrysene | 14.14 |
72. | Bis(2-ethylhexyl)phthalate | 14.2 |
73. | Di-n-octyl phthalate | 15.77 |
74. | Benzo[b]fluoranthene | 16.57 |
75. | Benzo[k]fluoranthene | 16.64 |
76. | Benzo[a]pyrene | 17.38 |
77. | Perylene-d12 (IS) | 17.52 |
78. | Indeno[1,2,3-cd]pyrene | 20.18 |
79. | Dibenzo[a,h]anthracene | 20.26 |
80. | Benzo[ghi]perylene | 20.81 |
Column | Rtx-5MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12623) |
---|---|
Standard/Sample | CLP standard |
Conc.: | 80 ng |
Injection | splitless |
Inj. Temp.: | 300 °C |
Oven | |
Oven Temp.: | 40 °C (hold 2 min) to 245 °C at 25 °C/min to 330 °C at 6 °C/min (hold 5 min) |
Carrier Gas | He, constant flow |
Flow Rate: | 1.0 mL/min |
Detector | MS |
---|---|
Mode: | Scan |
Source Temp.: | 280 °C |
Scan Range: | 35-550 amu |