Peaks | tR (min) | |
---|---|---|
1. | Dichlorodifluoromethane (CFC-12) | 2.198 |
2. | Chloromethane | 2.459 |
3. | Vinyl chloride | 2.659 |
4. | Bromomethane | 3.226 |
5. | Chloroethane | 3.434 |
6. | Trichlorofluoromethane (CFC-11) | 3.876 |
7. | Diethyl ether (ethyl ether) | 4.44 |
8. | 1,1-Dichloroethene | 4.909 |
9. | 1,1,2-Trichlorotrifluoroethane (CFC-113) | 4.998 |
10. | Acetone | 5.029 |
11. | Iodomethane | 5.195 |
12. | Carbon disulfide | 5.323 |
13. | Acetonitrile | 5.637 |
14. | Allyl chloride | 5.715 |
15. | Methyl acetate | 5.723 |
16. | Methylene chloride | 5.981 |
17. | tert-Butyl alcohol | 6.234 |
18. | Acrylonitrile | 6.451 |
19. | Methyl tert-butyl ether (MTBE) | 6.509 |
20. | trans-1,2-Dichloroethene | 6.512 |
21. | 1,1-Dichloroethane | 7.315 |
22. | Vinyl acetate | 7.359 |
23. | Diisopropyl ether (DIPE) | 7.407 |
24. | Chloroprene | 7.429 |
25. | Ethyl tert-butyl ether (ETBE) | 7.97 |
26. | 2-Butanone (MEK) | 8.193 |
27. | cis-1,2-Dichloroethene | 8.193 |
28. | 2,2-Dichloropropane | 8.193 |
29. | Ethyl acetate | 8.265 |
30. | Propionitrile | 8.276 |
31. | Methyl acrylate | 8.318 |
32. | Methacrylonitrile | 8.476 |
33. | Bromochloromethane | 8.507 |
34. | Tetrahydrofuran | 8.521 |
35. | Chloroform | 8.651 |
Peaks | tR (min) | |
---|---|---|
36. | 1,1,1-Trichloroethane | 8.843 |
37. | Dibromofluoromethane | 8.848 |
38. | Carbon tetrachloride | 9.026 |
39. | 1,1-Dichloropropene | 9.037 |
40. | 1,2-Dichloroethane-d4 | 9.246 |
41. | Benzene | 9.262 |
42. | 1,2-Dichloroethane | 9.334 |
43. | Isopropyl acetate | 9.34 |
44. | Isobutyl alcohol | 9.421 |
45. | tert-Amyl methyl ether (TAME) | 9.421 |
46. | Fluorobenzene | 9.598 |
47. | Trichloroethene | 9.976 |
48. | 1,2-Dichloropropane | 10.243 |
49. | Methyl methacrylate | 10.29 |
50. | 1,4-Dioxane (ND) | 10.299* |
51. | Dibromomethane | 10.326 |
52. | Propyl acetate | 10.346 |
53. | 2-Chloroethanol (ND) | 10.368* |
54. | Bromodichloromethane | 10.496 |
55. | 2-Nitropropane | 10.698 |
56. | cis-1,3-Dichloropropene | 10.904 |
57. | 4-Methyl-2-pentanone (MIBK) | 11.026 |
58. | Toluene-D8 | 11.148 |
59. | Toluene | 11.21 |
60. | trans-1,3-Dichloropropene | 11.407 |
61. | Ethyl methacrylate | 11.435 |
62. | 1,1,2-Trichloroethane | 11.585 |
63. | Tetrachloroethene | 11.662 |
64. | 1,3-Dichloropropane | 11.729 |
65. | 2-Hexanone | 11.749 |
66. | Butyl acetate | 11.837 |
67. | Dibromochloromethane | 11.921 |
68. | 1,2-Dibromoethane (EDB) | 12.035 |
69. | Chlorobenzene-d5 | 12.412 |
70. | Chlorobenzene | 12.44 |
Peaks | tR (min) | |
---|---|---|
71. | Ethylbenzene | 12.507 |
72. | 1,1,1,2-Tetrachloroethane | 12.507 |
73. | m-Xylene | 12.612 |
74. | p-Xylene | 12.612 |
75. | o-Xylene | 12.935 |
76. | Styrene | 12.949 |
77. | n-Amyl acetate | 13.018 |
78. | Bromoform | 13.118 |
79. | Isopropylbenzene (cumene) | 13.226 |
80. | cis-1,4-Dichloro-2-butene | 13.268 |
81. | 4-Bromofluorobenzene | 13.385 |
82. | 1,1,2,2-Tetrachloroethane | 13.456 |
83. | trans-1,4-Dichloro-2-butene | 13.496 |
84. | Bromobenzene | 13.515 |
85. | 1,2,3-Trichloropropane | 13.526 |
86. | n-Propylbenzene | 13.565 |
87. | 2-Chlorotoluene | 13.657 |
88. | 1,3,5-Trimethylbenzene | 13.699 |
89. | 4-Chlorotoluene | 13.751 |
90. | tert-Butylbenzene | 13.965 |
91. | Pentachloroethane | 14.007 |
92. | 1,2,4-Trimethylbenzene | 14.01 |
93. | sec-Butylbenzene | 14.14 |
94. | 4-Isopropyltoluene (p-cymene) | 14.254 |
95. | 1,3-Dichlorobenzene | 14.263 |
96. | 1,4-Dichlorobenzene-D4 | 14.321 |
97. | 1,4-Dichlorobenzene | 14.34 |
98. | n-Butylbenzene | 14.579 |
99. | 1,2-Dichlorobenzene | 14.635 |
100. | 1,2-Dibromo-3-chloropropane (DBCP) | 15.252 |
101. | Nitrobenzene | 15.407 |
102. | 1,2,4-Trichlorobenzene | 15.935 |
103. | Hexachloro-1,3-butadiene | 16.04 |
104. | Naphthalene | 16.196 |
105. | 1,2,3-Trichlorobenzene | 16.396 |
Column | Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 13868) |
---|---|
Standard/Sample | 8260A surrogate mix (cat.# 30240) |
8260A internal standard mix (cat.# 30241) | |
8260B MegaMix calibration mix (cat.# 30633) | |
VOA calibration mix #1 (ketones) (cat.# 30006) | |
8260B acetate mix (revised) (cat.# 30489) | |
California oxygenates mix (cat.# 30465) | |
502.2 calibration mix #1 (gases) (cat.# 30042) | |
Conc.: | 25 ppb in RO water |
Injection | purge and trap split (split ratio 30:1) |
Inj. Temp.: | 225 °C |
Purge and Trap | |
Instrument: | OI Analytical 4660 |
Trap Type: | 10 Trap |
Purge: | 11 min @ 20 °C |
Desorb Preheat Temp.: | 180 °C |
Desorb: | 0.5 min @ 190 °C |
Bake: | 5 min @ 210 °C |
Interface Connection: | injection port |
Oven | |
Oven Temp.: | 35 °C (hold 5 min) to 60 °C at 11 °C/min to 220 °C at 20 °C/min (hold 2 min) |
Carrier Gas | He, constant flow |
Flow Rate: | 1.0 mL/min |
Detector | MS |
---|---|
Mode: | Scan |
Transfer Line Temp.: | 230 °C |
Analyzer Type: | Quadrupole |
Source Temp.: | 230 °C |
Quad Temp.: | 150 °C |
Electron Energy: | 70 eV |
Solvent Delay Time: | 1.5 min |
Tune Type: | BFB |
Ionization Mode: | EI |
Scan Range: | 36-260 amu |
Instrument | Agilent 7890A GC & 5975C MSD |
Notes | Other Purge-and-Trap Conditions: Sample Inlet: 40°C Sample: 40°C Water Management: Purge 110°C, Desorb 0°C, Bake, 240°C |
Acknowledgement | Eclipse 4660 purge-and-trap courtesy of O.I. Analytical, College Station, TX. |