Peaks | tR (min) | Conc. (µg/mL) | Quant Ion | |
---|---|---|---|---|
1. | Naphthalene-D8 | 6.17 | 2.0 | 128 |
2. | Naphthalene | 6.21 | 9.3 | 136 |
3. | 2-Methylnaphthalene | 7.08 | 2.5 | 142 |
4. | 1-Methylnaphthalene | 7.32 | 2.5 | 142 |
5. | Biphenyl | 7.97 | 4.9 | 154 |
6. | 2,6-Dimethylnaphthalene | 8.12 | 2.5 | 156 |
7. | Acenaphthylene | 9.39 | 7.1 | 162 |
8. | Acenaphthene-D10 | 9.65 | 2.0 | 152 |
9. | Acenaphthene | 9.77 | 6.8 | 153 |
10. | 2,3,5-Trimethylnaphthalene | 10.42 | 2.5 | 170 |
11. | Fluorene | 11.6 | 6.4 | 165 |
12. | Dibenzothiophene | 16.81 | 4.4 | 184 |
13. | Phenanthrene-D10 | 17.56 | 2.0 | 188 |
14. | Phenanthrene | 17.76 | 9.4 | 178 |
15. | Anthracene | 18.07 | 6.0 | 178 |
16. | 4H-Cyclopenta[def]phenanthrene | 22.93 | 1.0 | 190 |
17. | 1-Methylphenanthrene | 22.93 | 2.5 | 192 |
18. | Fluoranthene | 29.64 | 8.0 | 202 |
19. | Pyrene | 32.82 | 8.2 | 202 |
20. | Benzo[c]fluorene | 37.75 | 2.5 | 216 |
21. | Benzo[ghi]fluoranthene | 46.14 | 1.5 | 226 |
22. | Benzo[c]phenanthrene | 46.38 | 2.0 | 228 |
23. | Benz[a]anthracene | 49.13 | 8.8 | 228 |
24. | Cyclopenta[cd]pyrene | 49.64 | 5.2 | 226 |
25. | Chrysene-D12 | 49.73 | 2.0 | 240 |
26. | Triphenylene | 49.96 | 1.8 | 228 |
Peaks | tR (min) | Conc. (µg/mL) | Quant Ion | |
---|---|---|---|---|
27. | Chrysene | 50.15 | 8.9 | 228 |
28. | 5-Methylchrysene | 56.24 | 4.4 | 242 |
29. | Benzo[b]fluoranthene | 63.86 | 10 | 252 |
30. | Benzo[k]fluoranthene | 64.13 | 8.3 | 252 |
31. | Benzo[j]fluoranthene | 64.29 | 6.1 | 252 |
32. | Benzo[a]fluoranthene | 65.10 | 0.99 | 252 |
33. | Benzo[e]pyrene | 67.15 | 2.0 | 252 |
34. | Benzo[a]pyrene-D12 | 67.38 | 2.0 | 264 |
35. | Benzo[a]pyrene | 67.63 | 8.9 | 252 |
36. | Perylene-D12 | 68.38 | 2.0 | 264 |
37. | Perylene | 68.62 | 1.9 | 252 |
38. | Dibenzo[a,j]anthracene | 74.46 | 2.0 | 278 |
39. | Dibenzo[a,c]anthracene | 75.18 | 1.3 | 278 |
40. | Indeno[1,2,3-cd]pyrene | 75.31 | 8.8 | 276 |
41. | Dibenzo[a,h]anthracene | 75.39 | 8.8 | 278 |
42. | Benzo[b]chrysene | 76.11 | 1.8 | 278 |
43. | Picene | 76.45 | 1.4 | 278 |
44. | Benzo[ghi]perylene | 77.08 | 9.3 | 276 |
45. | Anthanthrene | 77.87 | 0.95 | 276 |
46. | Dibenzo[b,k]fluoranthene | 82.23 | 0.71 | 302 |
47. | Dibenzo[a,l]pyrene | 82.51 | 4.4 | 302 |
48. | Dibenzo[a,e]pyrene | 84.18 | 5.3 | 302 |
49. | Coronene-D12 | 84.36 | 2.0 | 312 |
50. | Coronene | 84.51 | 0.98 | 300 |
51. | Dibenzo[a,i]pyrene | 85.15 | 4.4 | 302 |
52. | Dibenzo[a,h]pyrene | 85.66 | 4.4 | 302 |
Column | Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317) |
---|---|
Standard/Sample | SV internal standard mix (cat.# 31206) |
Coronene-D12 (CIL) (cat.# DLM-2715) | |
Benzo[a]pyrene-D12 (CIL) (cat.# DLM-258-0) | |
Aromatics in toluene (NIST) (cat.# 2260a) | |
Native PAH stock (Wellington Labs) (cat.# PAH-STK-A) | |
EU 15+1 PAH standard (cat.# 32470) | |
Custom PAH SIM standard (cat.# 557484) | |
Diluent: | Toluene |
Conc.: | 0.71 to 10 µg/mL |
Injection | |
Inj. Vol.: | 1 µL split (split ratio 10:1) |
Liner: | Premium 4 mm Precision liner w/wool (cat.# 23305.1) |
Inj. Temp.: | 275 °C |
Oven | |
Oven Temp.: | 110 °C (hold 1.6 min) to 175 °C at 30 °C/min to 265 °C at 1.6 °C/min to 350 °C at 4 °C/min (hold 15 min) |
Carrier Gas | He, constant flow |
Flow Rate: | 1.0 mL/min |
Detector | MS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mode: | SIM | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SIM Program: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Transfer Line Temp.: | 320 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Analyzer Type: | Quadrupole | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Source Type: | Extractor | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Extractor Lens: | 9 mm ID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Source Temp.: | 350 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Quad Temp.: | 200 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solvent Delay Time: | 3 min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ionization Mode: | EI | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Instrument | Agilent 7890B GC & 5977A MSD | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Notes | Conditions optimized using EZGC software produce good separation of dibenzo[a,c]anthracene and dibenzo[a,h]anthracene from indeno[1,2,3-cd]pyrene, triphenylene from chrysene, as well as the benzofluoranthene isomers. |