Peaks | |
---|---|
1. | Ethyl octanoate |
2. | Acetic acid |
3. | Siloxane |
4. | 1-Hydroxy-2,3-butadione |
5. | 1-Hydroxy-2-propanone acetate |
6. | Furfural |
7. | Formic acid |
8. | Propionic acid |
9. | Isobutyric acid |
10. | Dimethyl Sulfoxide |
11. | 5-Methyl furfural |
12. | Methyl decanoate + unknown |
13. | Butyric acid |
14. | Siloxane |
15. | Ethyl decanoate |
16. | Furfuryl alcohol |
17. | Isoamyl octanoate |
18. | Isovaleric acid |
19. | 2-Methylbutyric acid |
20. | Diethyl succinate |
21. | 3-Methyl-2(5H)-furanone (possible) |
22. | Valeric acid |
23. | Ethyl undecanoate |
24. | Isobutyl decanoate |
25. | 2(5H)-Furanone |
26. | Unknown |
27. | Diethylene glycol butyl ether |
28. | Siloxane |
29. | Methyl dodecanoate |
30. | 2-Phenylethyl acetate |
31. | Methylcyclopentenolone |
32. | Hexanoic acid |
Peaks | |
---|---|
33. | Ethyl dodecanoate |
34. | Isoamyl decanoate |
35. | Guaiacol |
36. | Dodecyl acetate (possible) |
37. | Whiskey lactone (1) |
38. | 2-Phenylethanol |
39. | Heptanoic acid |
40. | Siloxane |
41. | Dimethoxybenzene or 4-Methylguaiacol |
42. | Whiskey lactone (2) |
43. | Dodecanol |
44. | Unknown |
45. | Phenol |
46. | Methyl tetradecanoate |
47. | Nerolidol |
48. | Diethyl malate |
49. | Ethyl tetradecanoate |
50. | Octanoic Acid |
51. | Unknown |
52. | p-Cresol |
53. | Siloxane |
54. | Diethyl octanedioate |
55. | Monomethyl succinate (possible) |
56. | 3,5-Dimethyl-2,4(5H)furandione |
57. | Nonanoic acid |
58. | Diethyl 2-hydroxyglutarate |
59. | Unknown |
60. | Tetradecanol |
61. | 4-Vinylguaiacol |
62. | Diethyl nonanedioate |
63. | Methyl hexadecanoate |
64. | Ethyl γ-lactone 2-hydroxyglutarate |
Peaks | |
---|---|
65. | Ethyl hexadecanoate |
66. | Decanoic acid |
67. | Ethyl 9-hexadecanoate |
68. | Triacosan |
69. | Unknown |
70. | Phthalide |
71. | Diethyl Phthalate |
72. | Hexadecanol |
73. | 4-Hydroxycinnamic acid (decomp.) |
74. | Methyl stearate |
75. | Benzoic acid |
76. | Methyl 8-octadecenoate |
77. | Ethyl stearate |
78. | Dodecanoic acid |
79. | Hydroxymethylfurfural |
80. | Ethyl linoleate |
81. | 4-Allyl-2,6-dimethoxyphenol |
82. | Diisobutyl phthalate |
83. | Vanillin |
84. | Sinapic acid (decomp.) |
85. | 2-Phenylethyl decanoate +2 unknowns |
86. | 4-Propenyl-2,6-dimethoxyphenol |
87. | Ethyl vanillate |
88. | Acetovanillone |
89. | Vanillin methyl ketone |
90. | Tetradecanoic acid |
91. | Ethyl homovanillate |
92. | propiovanillone |
93. | fatty acid ester |
94. | similar to 4-Allyl-2,6-dimethoxyphenol |
95. | Unknown |
96. | Hexadecanoic acid |
97. | Syringaldehyde |
Column | Stabilwax-DA, 30 m, 0.18 mm ID, 0.18 µm |
---|---|
Standard/Sample | malt whiskey |
Conc.: | neat |
Injection | |
Inj. Vol.: | 10 µL PTV splitless |
Inlet Temp. Program: | 35 °C (hold 2 min) to 300 °C at 10 °C/min (hold 5 min) |
Oven | |
Oven Temp.: | 60 °C (hold 2 min) to 100 °C at 20 °C/min to 240 °C at 5 °C/min (hold 10 min) |
Carrier Gas | He, constant linear velocity |
Linear Velocity: | 45 cm/sec |
Detector | MS |
---|---|
Mode: | Scan |
Transfer Line Temp.: | 240 °C |
Analyzer Type: | Quadrupole |
Source Temp.: | 230 °C |
Quad Temp.: | 150 °C |
Electron Energy: | 70 eV |
Ionization Mode: | EI |
Scan Range: | 30-400 amu |
Notes | Injection: 10 µL large volume at 10 µL/min. Helium vent flow: 600 mL/min. with 1.8 min. vent end time |