Peaks | Conc. (µg/mL) | tR (30 m) | tR (LPGC) | |
---|---|---|---|---|
1. | Chloroneb | 0.4 | 10.337 | 4.225 |
2. | Pentachlorobenzene | 0.4 | 10.562 | 4.320 |
3. | α-BHC | 0.4 | 12.956 | 4.939 |
4. | Hexachlorobenzene | 0.4 | 13.154 | 4.997 |
5. | Pentachloroanisole | 0.4 | 13.273 | 5.017 |
6. | β-BHC | 0.4 | 13.610 | 5.106 |
7. | δ-BHC | 0.4 | 13.773 | 5.154 |
8. | γ-BHC | 0.4 | 14.341 | 5.293 |
9. | Tefluthrin | 0.4 | 14.466 | 5.232 |
10. | Endosulfan ether | 0.4 | 14.803 | 5.419 |
11. | Transfluthrin | 0.4 | 15.415 | 5.490 |
12. | Heptachlor | 0.4 | 15.504 | 5.592 |
13. | Pentachlorothioanisole | 0.4 | 16.086 | 5.745 |
14. | Anthraquinone | 0.4 | 16.279 | 5.803 |
15. | Aldrin | 0.4 | 16.317 | 5.803 |
16. | 4,4'-Dichlorobenzophenone | 0.4 | 16.511 | 5.827 |
17. | Fenson | 0.4 | 16.708 | 5.885 |
18. | Isodrin | 0.4 | 16.987 | 5.980 |
19. | Heptachlor epoxide | 0.4 | 17.235 | 6.035 |
20. | Bioallethrin | 0.4 | 17.405 | 5.994 |
21. | Chlorbenside | 0.4 | 17.626 | 6.123 |
22. | trans-Chlordane | 0.4 | 17.766 | 6.167 |
23. | 2,4'-DDE | 0.4 | 17.871 | 6.171 |
24. | Endosulfan I | 0.4 | 18.052 | 6.249 |
25. | cis-Chlordane | 0.4 | 18.109 | 6.256 |
26. | trans-Nonachlor | 0.4 | 18.218 | 6.279 |
27. | Chlorfenson | 0.4 | 18.232 | 6.226 |
28. | 4,4'-DDE | 0.4 | 18.569 | 6.337 |
29. | Dieldrin | 0.4 | 18.630 | 6.395 |
30. | 2,4'-DDD | 0.4 | 18.756 | 6.395 |
31. | Ethylan | 0.4 | 19.106 | 6.460 |
Peaks | Conc. (µg/mL) | tR (30 m) | tR (LPGC) | |
---|---|---|---|---|
32. | Endrin | 0.4 | 19.116 | 6.550 |
33. | Endosulfan II | 0.4 | 19.303 | 6.528 |
34. | 4,4'-DDD | 0.4 | 19.480 | 6.575 |
35. | 2,4'-DDT | 0.4 | 19.562 | 6.603 |
36. | cis-Nonachlor | 0.4 | 19.592 | 6.633 |
37. | Endrin aldehyde | 0.4 | 19.715 | 6.674 |
38. | 4,4'-Methoxychlor olefin | 0.4 | 20.079 | 6.708 |
39. | Endosulfan sulfate | 0.4 | 20.225 | 6.803 |
40. | 4,4'-DDT | 0.4 | 20.290 | 6.783 |
41. | 2,4'-Methoxychlor | 0.4 | 20.521 | 6.827 |
42. | Resmethrin | 0.4 | 20.793 | 5.980 |
43. | Endrin ketone | 0.4 | 21.235 | 7.082 |
44. | Tetramethrin 1 | 0.4 | 21.245 | 6.990 |
45. | Tetramethrin 2 | 0.4 | 21.388 | 7.018 |
46. | Bifenthrin | 0.4 | 21.402 | 7.011 |
47. | Phenothrin 1 | 0.4 | 21.841 | 7.130 |
48. | Tetradifon | 0.4 | 21.939 | 7.211 |
49. | Phenothrin 2 | 0.4 | 21.956 | 7.157 |
50. | Mirex | 0.4 | 22.436 | 7.388 |
51. | lambda-Cyhalothrin | 0.4 | 22.545 | 7.293 |
52. | Acrinathrin | 0.4 | 22.742 | 7.310 |
53. | cis-Permethrin | 0.4 | 23.388 | 7.535 |
54. | trans-Permethrin | 0.4 | 23.534 | 7.565 |
55. | Cyfluthrins | 0.4 | 24.065-24.310 | 7.698-7.745 |
56. | Cypermethrins | 0.4 | 24.436-24.677 | 7.793-7.847 |
57. | Flucythrinate 1 | 0.4 | 24.677 | 7.844 |
58. | Flucythrinate 2 | 0.4 | 24.898 | 7.899 |
59. | Fenvalerate 1 | 0.4 | 25.500 | 8.079 |
60. | tau-Fluvalinate 1 | 0.4 | 25.715 | 8.113 |
61. | Fenvalerate 2 | 0.4 | 25.732 | 8.140 |
62. | tau-Fluvalinate 2 | 0.4 | 25.773 | 8.113 |
63. | Deltamethrin | 0.4 | 26.337 | 8.324 |
Column | |
---|---|
Standard/Sample | GC multiresidue pesticide standard #2 (cat.# 32564) |
GC multiresidue pesticide standard #6 (cat.# 32568) | |
Diluent: | Acetonitrile |
Conc.: | 2 µg/mL |
Injection | |
Inj. Vol.: | 2 µL split (split ratio 10:1) |
Liner: | Topaz 4.0 mm ID straight inlet liner w/ wool (cat.# 23444) |
Inj. Temp.: | 250 °C |
Oven | |
Carrier Gas | He |
Detector | TSQ 8000 | |
---|---|---|
SIM Program: | 35-550 m/z | |
Transfer Line Temp.: | 290 °C | |
Analyzer Type: | Quadrupole | |
Source Temp.: | 330 °C | |
Tune Type: | PFTBA | |
Ionization Mode: | EI | |
Instrument | Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS | |
Notes | Conventional (30 m) Analysis: Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423) Temp. program: 90 °C (hold 1 min) to 330 °C at 8.5 °C/min (hold 5 min) Flow: 1.4 mL/min LPGC-MS Analysis: Column: Low-pressure GC column kit (factory-coupled restrictor column [5 m x 0.18 mm ID] and Rtx-5ms analytical column [15 m, 0.53 mm ID, 1 µm plus 1 m integrated transfer line on the outlet end]) (cat.# 11800) Temp. program: 80 °C (hold 1 min) to 320 °C at 35 °C/min (hold 5 min) Flow: 2 mL/min |