Canadian Pesticides on Rxi-5ms

GC_GN1217
PeakstR (min)Mix
1.Dichlorvos4.65-
2.Novaluron5.011
3.Mevinphos5.502
4.Acephate5.562
5.Etridiazole5.674
6.Oxamyl5.991
7.Flonicamid6.245
8.Propoxur6.311
9.Ethoprophos6.422
10.Naled6.562
11.Dimethoate6.892
12.Carbofuran6.901
13.Diazinon7.152
14.Pentachloronitrobenzene7.175
15.Pirimicarb7.441
16.Spiroxamine 17.696
17.Methyl parathion7.752
18.Carbaryl7.821
19.Metalaxyl7.875
20.Spiroxamine 28.016
21.Methiocarb8.051
22.Kinoprene8.126
23.Malathion8.142
24.Fenthion8.312
25.Chlorpyrifos8.332
26.MGK-264 18.566
27.Dodemorph 18.586
28.Thiamethoxam8.625
29.Cyprodinil8.704
PeakstR (min)Mix
30.MGK-264 28.736
31.Dodemorph 28.856
32.Allethrin8.863
33.Fluopyram8.875
34.Fipronil8.884
35.Methoprene8.936
36.Prallethrin9.073
37.Paclobutrazol9.334
38.Tetrachlorvinphos9.362
39.Endosulfan I9.536
40.Imazalil9.704
41.Fludioxonil9.744
42.Pyrethrin 1 (Cinerin)9.933
43.Myclobutanil9.944
44.Buprofezin9.985
45.Kresoxim-methyl10.006
46.Chlorfenapyr10.264
47.Fensulfothion10.492
48.Endosulfan II10.556
49.Trifloxystrobin11.206
50.Propiconazole 111.214
51.Endosulfan sulfate11.336
52.Propiconazole 211.344
53.Tebuconazole11.584
54.Piperonyl butoxide11.686
55.Resmethrin11.723
56.Iprodione12.041
57.Spiromesifen12.053
58.Tetramethrin12.153
PeakstR (min)Mix
59.Fenoxycarb12.221
60.Acetamiprid12.236
61.Phosmet12.262
62.Bifenthrin12.283
63.Bifenazate12.321
64.Etoxazole12.454
65.Chlorantraniliprole fragment12.525
66.Phenothrin 112.683
67.Phenothrin 212.793
68.Pyrethrin 1 (Cinerin)12.903
69.cis-Permethrin14.103
70.Spirodiclofen14.153
71.trans-Permethrin14.223
72.Pyridaben14.264
73.Coumaphos14.362
74.Cyfluthrin14.70-14.923
75.Spirotetramat14.725
76.Cypermethrin15.03-15.343
77.Boscalid15.135
78.Acequinocyl15.336
79.Fenvalerate 115.983
80.Pyraclostrobin16.041
81.Fenvalerate 216.183
82.Deltamethrin16.723
83.Azoxystrobin16.994
84.Dimethomorph 117.035
85.Dimethomorph 217.315
86.Chlorantraniliprole fragment19.215
87.Cyantraniliprole20.415
ColumnRxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Standard/SampleCanadian pesticides standard #1 (cat.# 32593)
Canadian pesticides standard #2 (cat.# 32594)
Canadian pesticides standard #3 (cat.# 32595)
Canadian pesticides standard #4 (cat.# 32596)
Canadian pesticides standard #5 (cat.# 32597)
Canadian pesticides standard #6 (cat.# 32598)
Azadirachtin standard (cat.# 32599)
Dichlorvos standard (cat.# 32585)
Diluent:Acetonitrile
Conc.:10 µg/mL
Injection
Inj. Vol.:1 µL splitless (hold 0.5 min)
Liner:Topaz 4.0 mm ID single taper inlet liner w/wool (cat.# 23447)
Inj. Temp.:250 °C
Purge Flow:5 mL/min
Oven
Oven Temp.:70 °C (hold 1 min) to 220 °C at 30 °C/min to 240 °C at 5 °C/min to 315 °C at 10 °C/min (hold 10 min)
Carrier GasHe, constant flow
Flow Rate:1.4 mL/min
DetectorThermo TSQ8000
Scan Program:
GroupStart Time
(min)
Scan Range
(amu)
Scan Rate
(scans/sec)
12.555-55010
Transfer Line Temp.:290 °C
Analyzer Type:Quadrupole
Source Temp.:330 °C
Solvent Delay Time:2.5 min
Tune Type:PFTBA
Ionization Mode:EI
Sample Preparation100 µL of each standard was combined with 200 µL acetonitrile (final volume 1 mL) for a final concentration of 10 ppm. The sample was pipetted into a 2 mL short-cap, screw-thread vial (cat.# 21143) and capped with a short-cap, screw-vial closure (cat.# 24495).
NotesSome compounds traditionally analyzed by LC were not GC amenable and/or only fragments were detected.
Canadian pesticide standards are also available as a kit: Canadian pesticides kit (cat.# 32592).