Peaks | tR (min) | Quant. Ion (m/z) | Qual. Ion #1 (m/z) | Qual. Ion #2 (m/z) | |
---|---|---|---|---|---|
1. | o-Toluidine | 1.14 | 106 | 107 | 89 |
2. | o-Anisidine | 1.56 | 108 | 123 | 80 |
3. | 4-Chloroaniline | 1.71 | 127 | 129 | 100 |
4. | p-Cresidine | 1.95 | 122 | 137 | 94 |
5. | 2,4,5-Trimethylaniline | 1.97 | 120 | 135 | 134 |
6. | 3-Chloro-o-toluidine | 2.08 | 141 | 106 | 140 |
7. | 4-Chloro-o-toluidine | 2.13 | 141 | 106 | 140 |
8. | 2,4-Diaminotoluene | 2.70 | 121 | 122 | 94 |
9. | 2,4,5-Trichloroaniline (IS) | 3.25 | 195 | 197 | 199 |
10. | 2-Naphthylamine | 3.46 | 143 | 115 | 116 |
11. | 2-Aminobiphenyl | 3.50 | 169 | 168 | 167 |
12. | 2-Amino-4-nitrotoluene | 3.73 | 152 | 106 | 79 |
Peaks | tR (min) | Quant. Ion (m/z) | Qual. Ion #1 (m/z) | Qual. Ion #2 (m/z) | |
---|---|---|---|---|---|
13. | 4-Aminobiphenyl | 4.31 | 169 | 168 | 167 |
14. | p-Aminoazobenzene | 5.66 | 92 | 197 | 120 |
15. | 4,4'-Oxydianiline | 5.90 | 200 | 171 | 108 |
16. | 4,4'-Diaminodiphenylmethane | 5.94 | 198 | 197 | 180 |
17. | Benzidine | 5.96 | 184 | 185 | 92 |
18. | o-Aminoazotoluene | 6.23 | 106 | 225 | 134 |
19. | 3,3'-Dimethyl-4,4'-diaminodiphenylmethane | 6.48 | 226 | 120 | 211 |
20. | 3,3'-Dimethylbenzidine | 6.57 | 212 | 213 | 106 |
21. | 4,4’-Thiodianiline | 6.92 | 216 | 184 | 183 |
22. | 3,3'-Dichlorobenzidine | 7.05 | 252 | 254 | 256 |
23. | 4,4'-Methylenebis(2-chloroaniline) | 7.05 | 231 | 266 | 195 |
24. | 3,3'-Dimethoxybenzidine | 7.09 | 244 | 201 | 186 |
Column | Rxi-35Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13820) |
---|---|
Standard/Sample | AccuStandard carcinogenic aryl amine mix (cat.# AE-000-49-R1) |
Diluent: | Ethyl acetate |
Conc.: | 10 µg/mL |
Injection | |
Inj. Vol.: | 1 µL split (split ratio 10:1) |
Liner: | Premium 4 mm Precision liner w/wool (cat.# 23305.1) |
Inj. Temp.: | 275 °C |
Oven | |
Oven Temp.: | 100 °C to 320 °C at 27 °C/min (hold 1.75 min) |
Carrier Gas | He, constant flow |
Flow Rate: | 2.0 mL/min |
Detector | MS | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mode: | SIM | ||||||||||||||||||||||||||||||||
SIM Program: | |||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||
Transfer Line Temp.: | 330 °C | ||||||||||||||||||||||||||||||||
Analyzer Type: | Quadrupole | ||||||||||||||||||||||||||||||||
Source Type: | Inert | ||||||||||||||||||||||||||||||||
Drawout Plate: | 3 mm ID | ||||||||||||||||||||||||||||||||
Source Temp.: | 250 °C | ||||||||||||||||||||||||||||||||
Quad Temp.: | 180 °C | ||||||||||||||||||||||||||||||||
Solvent Delay Time: | 1.0 min | ||||||||||||||||||||||||||||||||
Tune Type: | PFTBA | ||||||||||||||||||||||||||||||||
Ionization Mode: | EI | ||||||||||||||||||||||||||||||||
Instrument | Agilent 7890A GC & 5975C MSD |