Peaks | tR (min) | Precursor Ion | Product Ion | Product Ion | |
---|---|---|---|---|---|
1. | Norcotinine | 1.35 | 163.1 | 80.1 | 118.0 |
2. | Nicotine | 1.39 | 163.2 | 130.1 | 117.1 |
3. | BZP | 1.44 | 177.2 | 91.1 | 65.1 |
4. | Anabasine | 1.51 | 163.2 | 92.1 | 120.1 |
5. | Normorphine | 1.56 | 272.3 | 165.1 | 152.0 |
6. | Noroxymorphone | 1.80 | 288.2 | 270.2 | 213.2 |
7. | Lisdexamfetamine | 1.82 | 264.2 | 84.2 | 91.2 |
8. | Cotinine | 2.02 | 177.2 | 80.1 | 98.1 |
9. | Psilocybin | 2.04 | 285.3 | 205.2 | 58.3 |
10. | Dihydromorphine | 2.11 | 288.3 | 157.1 | 185.0 |
11. | Morphine | 2.16 | 286.2 | 152.1 | 165.1 |
12. | Morphine-6-β-D-glucuronide | 2.22 | 462.3 | 286.2 | 201.1 |
13. | Oxymorphone | 2.23 | 302.2 | 227.1 | 198.1 |
14. | Morphine-N-oxide | 2.31 | 302.3 | 285.2 | 162.1 |
15. | Hydromorphone | 2.41 | 286.2 | 185.1 | 157.2 |
16. | Psilocin | 2.42 | 205.2 | 58.3 | 160.1 |
17. | Olanzapine | 2.66 | 313.2 | 256.1 | 198.1 |
18. | Methylephedrine | 2.68 | 180.2 | 162.2 | 115.2 |
19. | Norcodeine | 2.69 | 286.1 | 152.1 | 115.0 |
20. | Naloxone | 2.90 | 328.3 | 271.1 | 310.1 |
21. | Methamphetamine | 2.93 | 150.3 | 91.1 | 119.2 |
22. | Noroxycodone | 2.98 | 302.1 | 284.2 | 227.1 |
23. | Dihydrocodeine | 2.98 | 302.2 | 199.2 | 128.0 |
24. | MDA | 2.98 | 180.2 | 163.1 | 105.2 |
25. | Codeine | 3.02 | 300.2 | 152.0 | 165.0 |
26. | O-Desmethyltramadol | 3.02 | 250.1 | 44.0 | 232.0 |
27. | 6-Acetylmorphine | 3.04 | 328.2 | 165.1 | 211.2 |
28. | Norhydrocodone | 3.05 | 286.2 | 199.1 | 128.2 |
29. | Phentermine | 3.07 | 150.3 | 91.1 | 133.2 |
30. | Methylone | 3.07 | 208.1 | 160.2 | 132.2 |
31. | Desomorphine | 3.18 | 272.1 | 165.0 | 152.2 |
32. | Oxycodone | 3.19 | 316.2 | 298.2 | 169.0 |
33. | Naltrexone | 3.24 | 342.2 | 324.3 | 267.2 |
34. | Hydrocodone | 3.27 | 300.2 | 199.2 | 128.2 |
35. | Levamisole | 3.31 | 205.1 | 178.1 | 91.2 |
36. | 7-Aminonitrazepam | 3.34 | 252.2 | 121.1 | 94.2 |
37. | O-Desmethylvenlafaxine | 3.38 | 264.2 | 58.2 | 107.0 |
38. | MDEA | 3.54 | 208.2 | 163.2 | 105.2 |
39. | m-Hydroxybenzoylecgonine | 3.59 | 306.2 | 168.2 | 121.1 |
40. | Lamotrigine | 3.62 | 256.1 | 210.9 | 145.0 |
41. | N-Desmethyltapentadol | 3.63 | 208.1 | 107.2 | 121.2 |
42. | Tapentadol | 3.76 | 222.2 | 107.2 | 121.2 |
43. | Hydroxybupropion | 3.80 | 256.0 | 166.0 | 130.2 |
44. | Molindone | 3.81 | 278.1 | 100.1 | 70.1 |
45. | Zolpidem Phenyl-4-carboxylic acid | 3.82 | 338.2 | 265.1 | 219.0 |
46. | Dextrorphan | 3.84 | 258.2 | 157.1 | 201.2 |
47. | Levorphanol | 3.84 | 258.2 | 157.2 | 199.2 |
48. | Tramadol | 3.86 | 264.2 | 58.2 | 77.0 |
49. | N-Desmethyltramadol | 3.98 | 250.2 | 44.1 | 232.1 |
50. | Methylphenidate | 4.00 | 234.4 | 84.2 | 56.1 |
51. | Lacosamide | 4.03 | 251.5 | 91.2 | 108.2 |
52. | Normeperidine | 4.06 | 234.1 | 160.2 | 91.0 |
53. | Benzoylecgonine | 4.11 | 290.2 | 168.2 | 77.2 |
54. | Remifentanil | 4.13 | 377.4 | 113.2 | 317.2 |
55. | Cocaine | 4.20 | 304.2 | 182.2 | 77.1 |
56. | 7-Aminoclonazepam | 4.24 | 286.1 | 121.2 | 250.1 |
57. | N-Desmethylclozapine | 4.25 | 313.0 | 192.1 | 270.1 |
58. | N-Desmethylmirtazapine | 4.27 | 252.1 | 195.2 | 209.2 |
59. | Norcocaine | 4.29 | 290.1 | 168.2 | 136.2 |
60. | MDPV | 4.29 | 276.2 | 126.3 | 135.2 |
61. | Pentazocine | 4.38 | 286.2 | 218.2 | 69.1 |
62. | Mirtazapine | 4.40 | 266.1 | 195.2 | 107.2 |
63. | Butorphanol | 4.47 | 328.3 | 310.2 | 131.0 |
64. | Clozapine | 4.49 | 328.2 | 271.0 | 193.0 |
Peaks | tR (min) | Precursor Ion | Product Ion | Product Ion | |
---|---|---|---|---|---|
65. | Paliperidone | 4.51 | 427.4 | 207.2 | 110.1 |
66. | Iloperidone | 4.51 | 427.1 | 207.2 | 110.2 |
67. | 9-Hydroxyrisperidone | 4.51 | 427.0 | 207.2 | 110.2 |
68. | Didemethylcitalopram | 4.73 | 297.1 | 109.2 | 262.1 |
69. | Citalopram | 4.75 | 325.2 | 109.2 | 262.1 |
70. | Escitalopram | 4.75 | 325.3 | 109.2 | 262.1 |
71. | Topiramate | 4.76 | 340.0 | 264.1 | 224.0 |
72. | Diphenhydramine | 4.76 | 256.2 | 167.2 | 152.1 |
73. | Haloperidol | 4.80 | 377.2 | 123.1 | 95.0 |
74. | Desmethyldoxepin | 4.82 | 266.1 | 115.0 | 107.2 |
75. | Ezogabine | 4.84 | 304.1 | 109.2 | 230.1 |
76. | Fluoxetine | 4.91 | 310.1 | 44.1 | 148.0 |
77. | Dextromethorphan | 5.01 | 272.2 | 215.2 | 171.1 |
78. | Chlordiazepoxide | 5.05 | 300.1 | 227.1 | 282.0 |
79. | Norpropoxyphene | 5.08 | 326.4 | 252.2 | 91.0 |
80. | Propoxyphene | 5.09 | 340.3 | 58.2 | 266.3 |
81. | Asenapine | 5.11 | 286.2 | 166.0 | 229.0 |
82. | Midazolam | 5.16 | 326.1 | 291.2 | 223.0 |
83. | Sufentanil | 5.16 | 387.3 | 238.2 | 111.1 |
84. | Protriptyline | 5.18 | 264.1 | 191.1 | 165.0 |
85. | Promazine | 5.19 | 285.1 | 86.2 | 58.2 |
86. | Amoxapine | 5.21 | 314.2 | 271.1 | 193.1 |
87. | Oxcarbazepine | 5.22 | 253.1 | 180.1 | 208.1 |
88. | Paroxetine | 5.23 | 330.2 | 192.2 | 70.2 |
89. | Phenytoin | 5.24 | 253.0 | 182.2 | 104.2 |
90. | Loxapine | 5.25 | 328.2 | 271.1 | 193.1 |
91. | Maprotiline | 5.26 | 278.1 | 250.3 | 191.1 |
92. | Cyclobenzaprine | 5.26 | 276.2 | 215.1 | 189.0 |
93. | Amitriptyline | 5.27 | 278.2 | 202.1 | 91.2 |
94. | EDDP | 5.27 | 278.2 | 234.1 | 249.2 |
95. | Venlafaxine | 5.27 | 278.4 | 260.2 | 121.2 |
96. | Nortriptyline | 5.29 | 264.1 | 91.0 | 115.0 |
97. | Tenoxicam | 5.32 | 338.1 | 121.2 | 95.0 |
98. | Trimipramine | 5.40 | 295.2 | 100.2 | 58.3 |
99. | Pimozide | 5.43 | 462.1 | 109.2 | 328.2 |
100. | Mesoridazine | 5.44 | 387.3 | 126.1 | 98.2 |
101. | α-Hydroxymidazolam | 5.48 | 342.2 | 324.1 | 203.1 |
102. | Clomipramine | 5.53 | 315.3 | 86.2 | 58.2 |
103. | Methadone | 5.55 | 310.2 | 265.2 | 105.2 |
104. | Sertraline | 5.56 | 306.1 | 158.9 | 275.1 |
105. | Metaxalone | 5.61 | 222.1 | 161.2 | 77.1 |
106. | Eslicarbazepine | 5.65 | 297.2 | 194.2 | 237.1 |
107. | EMDP | 5.68 | 264.2 | 220.1 | 235.2 |
108. | N-Desmethylflunitrazepam | 5.82 | 300.1 | 254.1 | 198.1 |
109. | Ketorolac | 5.89 | 256.1 | 105.2 | 77.1 |
110. | Etoricoxib | 5.95 | 359.2 | 280.1 | 279.1 |
111. | Clonazepam | 5.97 | 316.1 | 270.1 | 214.1 |
112. | Tolmetin | 6.03 | 258.1 | 119.2 | 91.1 |
113. | Thioridazine | 6.03 | 371.3 | 126.3 | 98.2 |
114. | α-Hydroxytriazolam | 6.04 | 359.2 | 331.1 | 176.0 |
115. | Methaqualone | 6.10 | 251.1 | 132.1 | 91.2 |
116. | α-Hydroxyalprazolam | 6.17 | 325.2 | 297.1 | 216.2 |
117. | Clobazam | 6.28 | 301.0 | 259.1 | 224.1 |
118. | Parecoxib | 6.32 | 371.2 | 234.1 | 165.0 |
119. | Zaleplon | 6.32 | 306.2 | 236.1 | 264.2 |
120. | Flunitrazepam | 6.39 | 314.2 | 268.1 | 239.1 |
121. | Temazepam | 6.43 | 301.1 | 255.2 | 283.1 |
122. | Estazolam | 6.44 | 295.1 | 267.1 | 205.1 |
123. | Diazepam | 6.74 | 285.1 | 193.1 | 154.2 |
124. | XLR-11 | 7.02 | 330.3 | 125.1 | 144.1 |
125. | Prazepam | 7.04 | 325.2 | 271.2 | 140.1 |
126. | THC | 7.15 | 315.2 | 193.0 | 123.1 |
127. | JWH-073 | 7.54 | 328.2 | 127.1 | 155.1 |
128. | JWH-018 | 7.64 | 342.3 | 155.2 | 127.1 |
Column | Force Biphenyl (cat.# 962935E) | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions: | 50 mm x 3.0 mm ID | ||||||||||||||||||||||||
Particle Size: | 3 µm | ||||||||||||||||||||||||
Pore Size: | 100 Å | ||||||||||||||||||||||||
Guard Column: | Force Biphenyl EXP guard column cartridge 5 mm, 3 mm ID, 5 µm (cat.# 962950253) | ||||||||||||||||||||||||
Temp.: | 30 °C | ||||||||||||||||||||||||
Standard/Sample | |||||||||||||||||||||||||
Diluent: | Water | ||||||||||||||||||||||||
Conc.: | 80 ng/mL | ||||||||||||||||||||||||
Inj. Vol.: | 1 µL | ||||||||||||||||||||||||
Mobile Phase | |||||||||||||||||||||||||
A: | Water, 0.1% formic acid | ||||||||||||||||||||||||
B: | Methanol, 0.1% formic acid | ||||||||||||||||||||||||
|
Detector | MS/MS |
---|---|
Ion Source: | Electrospray |
Ion Mode: | ESI+ |
Instrument | UHPLC |
Sample Preparation | Standards were prepared in a 2 mL screw-thread vial (cat.# 21143) and capped with a short-cap, screw-vial closure (cat.#24498). |
Notes | The analytical and guard columns were equipped with an UltraShield precolumn filter (cat. 25809). |