Peaks | tR (min) | Conc. (ng/mL) | Precursor Ion | Product Ion | |
---|---|---|---|---|---|
1. | Perfluoro-n-butanoic acid (PFBA) | 1.933 | 25 | 213 | 169 |
2. | Perfluoro-3-methoxypropanoic acid (PFMPA) | 2.544 | 25 | 229 | 85 |
3. | Perfluoro-n-pentanoic acid (PFPeA) | 3.369 | 25 | 263 | 219 |
4. | Perfluorobutanesulfonic acid (PFBS) | 3.594 | 25 | 299 | 80 |
5. | Perfluoro-4-methoxybutanoic acid (PFMBA) | 3.669 | 25 | 279 | 85 |
6. | Perfluoro(2-ethoxyethane)sulfonic acid (PFEESA) | 3.919 | 25 | 315 | 135 |
7. | Perfluoro-3,6-dioxaheptanoic acid (NFDHA) | 4.084 | 25 | 295 | 201 |
8. | 1H,1H,2H,2H-Perfluorohexane sulfonic acid (4:2 FTS) | 4.129 | 25 | 327 | 307 |
9. | Perfluorohexanoic acid (PFHxA) | 4.189 | 25 | 313 | 269 |
10. | Perfluoro-1-pentanesulfonic acid (PFPeS) | 4.278 | 25 | 349 | 80 |
11. | Perfluoro(2-methyl-3-oxahexanoic) acid (HFPO-DA) | 4.365 | 25 | 285 | 169 |
12. | Perfluoroheptanoic acid (PFHpA) | 4.715 | 25 | 363 | 319 |
Peaks | tR (min) | Conc. (ng/mL) | Precursor Ion | Product Ion | |
---|---|---|---|---|---|
13. | Perfluoro-1-hexanesulfonic acid (PFHxS) | 4.750 | 25 | 399 | 80 |
14. | 4,8-dioxa-3H-perfluorononanoic acid (ADONA) | 4.78 | 25 | 277 | 251 |
15. | 1H,1H,2H,2H-Perfluorooctane sulfonic acid (6:2 FTS) | 5.096 | 25 | 427 | 407 |
16. | Perfluoro-1-heptanesulfonic acid (PFHpS) | 5.132 | 25 | 449 | 80 |
17. | Perfluorooctanoic acid (PFOA) | 5.115 | 25 | 413 | 369 |
18. | Perfluorooctanesulfonic acid (PFOS) | 5.441 | 25 | 499 | 80 |
19. | Perfluorononanoic acid (PFNA) | 5.439 | 25 | 463 | 419 |
20. | 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS) | 5.588 | 25 | 531 | 351 |
21. | 1H,1H,2H,2H-Perfluorodecane sulfonic acid (8:2 FTS) | 5.712 | 25 | 527 | 507 |
22. | Perfluorodecanoic acid (PFDA) | 5.712 | 25 | 513 | 469 |
23. | Perfluoroundecanoic acid (PFUnA) | 5.954 | 25 | 563 | 519 |
24. | 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS) | 6.049 | 25 | 631 | 451 |
25. | Perfluorododecanoic acid (PFDoA) | 6.158 | 25 | 613 | 569 |
Column | Force C18 (cat.# 9634252) | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensions: | 50 mm x 2.1 mm ID | ||||||||||||||||||||||||
Particle Size: | 1.8 µm | ||||||||||||||||||||||||
Pore Size: | 100 Å | ||||||||||||||||||||||||
Temp.: | 40 °C | ||||||||||||||||||||||||
Standard/Sample | EPA 533 PFAS calibration standard (cat.# 30736) | ||||||||||||||||||||||||
Diluent: | 80:20 Methanol:water | ||||||||||||||||||||||||
Conc.: | 25 ng/mL | ||||||||||||||||||||||||
Inj. Vol.: | 3 µL | ||||||||||||||||||||||||
Mobile Phase | |||||||||||||||||||||||||
A: | Water, 5 mM ammonium acetate | ||||||||||||||||||||||||
B: | Methanol | ||||||||||||||||||||||||
|
Detector | Shimadzu 8045 |
---|---|
Ion Source: | Electrospray |
Ion Mode: | ESI- |
Mode: | MRM |
Instrument | Shimadzu Nexera X2 |
Notes | Branched isomers for PFOA, PFOS, and PFHxS labeled as peak number "a" and "b". PFAS delay column used (cat.# 27854). |