27067 |
Ferrules |
0.8 mm |
0.45/0.53 mm (fused silica); 0.53 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 27067
- Product Name
- Ferrules
- Ferrule ID
- 0.8 mm
- Fits Column ID
- 0.45/0.53 mm (fused silica); 0.53 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 10-pk.
|
20211 |
Ferrules |
0.4 mm |
0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 20211
- Product Name
- Ferrules
- Ferrule ID
- 0.4 mm
- Fits Column ID
- 0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 10-pk.
|
20212 |
Ferrules |
0.5 mm |
0.32 mm (fused silica); 0.25/0.32 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 20212
- Product Name
- Ferrules
- Ferrule ID
- 0.5 mm
- Fits Column ID
- 0.32 mm (fused silica); 0.25/0.32 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 10-pk.
|
20213 |
Ferrules |
0.8 mm |
0.45/0.53 mm (fused silica); 0.53 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 20213
- Product Name
- Ferrules
- Ferrule ID
- 0.8 mm
- Fits Column ID
- 0.45/0.53 mm (fused silica); 0.53 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 10-pk.
|
20218 |
Ferrules, Standard |
1/16" |
|
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 20218
- Product Name
- Ferrules, Standard
- Ferrule ID
- 1/16"
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 10-pk.
|
20229 |
Ferrules |
0.4 mm |
0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
50-pk. |
Select
Deselect
|
Catalog # 20229
- Product Name
- Ferrules
- Ferrule ID
- 0.4 mm
- Fits Column ID
- 0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 50-pk.
|
20230 |
Ferrules |
0.8 mm |
0.45/0.53 mm (fused silica); 0.53 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
50-pk. |
Select
Deselect
|
Catalog # 20230
- Product Name
- Ferrules
- Ferrule ID
- 0.8 mm
- Fits Column ID
- 0.45/0.53 mm (fused silica); 0.53 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 50-pk.
|
20231 |
Ferrules |
0.5 mm |
0.32 mm (fused silica); 0.25/0.32 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
50-pk. |
Select
Deselect
|
Catalog # 20231
- Product Name
- Ferrules
- Ferrule ID
- 0.5 mm
- Fits Column ID
- 0.32 mm (fused silica); 0.25/0.32 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 50-pk.
|
20232 |
Ferrules |
0.6 mm |
0.28 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
For 0.28 mm MXT columns. |
|
10-pk. |
Select
Deselect
|
Catalog # 20232
- Product Name
- Ferrules
- Ferrule ID
- 0.6 mm
- Fits Column ID
- 0.28 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Used with
- For 0.28 mm MXT columns.
- Units
- 10-pk.
|
20240 |
Blank Ferrules—For 1/16-Inch Fittings |
no hole |
|
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 20240
- Product Name
- Blank Ferrules—For 1/16-Inch Fittings
- Ferrule ID
- no hole
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 10-pk.
|
20275 |
Ferrules |
0.3 mm |
|
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 20275
- Product Name
- Ferrules
- Ferrule ID
- 0.3 mm
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 10-pk.
|
24848 |
Two-Hole Ferrule for Dual-Column Analysis |
0.4 mm |
0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
5-pk. |
Select
Deselect
|
Catalog # 24848
- Product Name
- Two-Hole Ferrule for Dual-Column Analysis
- Ferrule ID
- 0.4 mm
- Fits Column ID
- 0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 5-pk.
- Similar To
-
Agilent 5062-3580
|
24849 |
Two-Hole Ferrule for Dual-Column Analysis |
0.5 mm |
0.32 mm (fused silica); 0.25/0.32 mm (MXT) |
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
|
|
5-pk. |
Select
Deselect
|
Catalog # 24849
- Product Name
- Two-Hole Ferrule for Dual-Column Analysis
- Ferrule ID
- 0.5 mm
- Fits Column ID
- 0.32 mm (fused silica); 0.25/0.32 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Units
- 5-pk.
- Similar To
-
Agilent 5062-3581
|
24912 |
Ferrules |
1.0 mm |
|
1/16" |
VG2, 60% Vespel/40% Graphite |
|
|
For micropacked columns. |
|
10-pk. |
Select
Deselect
|
Catalog # 24912
- Product Name
- Ferrules
- Ferrule ID
- 1.0 mm
- Fitting Size
- 1/16"
- Material
- VG2, 60% Vespel/40% Graphite
- Used with
- For micropacked columns.
- Units
- 10-pk.
|
27061 |
Ferrules |
0.3 mm |
|
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 27061
- Product Name
- Ferrules
- Ferrule ID
- 0.3 mm
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 10-pk.
|
27062 |
Ferrules |
0.4 mm |
0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 27062
- Product Name
- Ferrules
- Ferrule ID
- 0.4 mm
- Fits Column ID
- 0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 10-pk.
|
27063 |
Ferrules |
0.4 mm |
0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
50-pk. |
Select
Deselect
|
Catalog # 27063
- Product Name
- Ferrules
- Ferrule ID
- 0.4 mm
- Fits Column ID
- 0.025/0.05/0.075/0.10/0.15/0.18/0.20/0.25 mm (fused silica); 0.18 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 50-pk.
|
27064 |
Ferrules |
0.5 mm |
0.32 mm (fused silica); 0.25/0.32 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 27064
- Product Name
- Ferrules
- Ferrule ID
- 0.5 mm
- Fits Column ID
- 0.32 mm (fused silica); 0.25/0.32 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 10-pk.
|
27065 |
Ferrules |
0.5 mm |
0.32 mm (fused silica); 0.25/0.32 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
50-pk. |
Select
Deselect
|
Catalog # 27065
- Product Name
- Ferrules
- Ferrule ID
- 0.5 mm
- Fits Column ID
- 0.32 mm (fused silica); 0.25/0.32 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 50-pk.
|
27066 |
Ferrules |
0.6 mm |
0.28 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
For 0.28 mm MXT columns. |
|
10-pk. |
Select
Deselect
|
Catalog # 27066
- Product Name
- Ferrules
- Ferrule ID
- 0.6 mm
- Fits Column ID
- 0.28 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Used with
- For 0.28 mm MXT columns.
- Units
- 10-pk.
|
27068 |
Ferrules |
0.8 mm |
0.45/0.53 mm (fused silica); 0.53 mm (MXT) |
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
50-pk. |
Select
Deselect
|
Catalog # 27068
- Product Name
- Ferrules
- Ferrule ID
- 0.8 mm
- Fits Column ID
- 0.45/0.53 mm (fused silica); 0.53 mm (MXT)
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 50-pk.
|
27069 |
Ferrules |
1.0 mm |
|
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
For micropacked columns. |
|
10-pk. |
Select
Deselect
|
Catalog # 27069
- Product Name
- Ferrules
- Ferrule ID
- 1.0 mm
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Used with
- For micropacked columns.
- Units
- 10-pk.
|
27076 |
Ferrules, Standard |
1/16" |
|
1/16" |
VG1, 85% Vespel/15% Graphite |
|
|
|
|
10-pk. |
Select
Deselect
|
Catalog # 27076
- Product Name
- Ferrules, Standard
- Ferrule ID
- 1/16"
- Fitting Size
- 1/16"
- Material
- VG1, 85% Vespel/15% Graphite
- Units
- 10-pk.
|