Restek Super Clean Gas Trapping System for LC-MS

A Super Clean quick-change cartridge system efficiently removes hydrocarbons from nitrogen!

  • Designed for easy, hassle-free cartridge changes.
  • Up to 20 L of hydrocarbon-free nitrogen per minute.
  • Filters connected in parallel to handle high flows for LC-MS.
  • Glass inside to prevent diffusion, polycarbonate housing outside for safety.
Documentation and Instructions Sheets

Restek Super Clean Gas Trapping System for LC-MS

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
22062 Super Clean Gas-Trapping System (2-position baseplate, 2 charcoal filters) 1/4" Brass ea. Select Deselect

Catalog # 22062

Product Name
Super Clean Gas-Trapping System (2-position baseplate, 2 charcoal filters)  
Fittings
1/4" Brass  
Units
ea.  
Note
This filter is packed under argon to maintain quality. Follow the installation instructions carefully to purge the argon from the filters before use.  

The Super Clean gas trapping system purifies nitrogen and is ideal for use in LC-MS systems. The two-position baseplate (installed in the gas line; standard baseplate inlet/outlet fittings accept 1/4" tubing) allows cartridges to be exchanged without introducing impurities into the system. Spring-loaded check valves seal when a cartridge is removed and open only when a new cartridge has been locked in place. There is no need for loosening and tightening fittings every time you change cartridges, and your system cannot become contaminated during the changing process.

To meet the high flow needs of the LC-MS system, the activated charcoal–filled cartridges are positioned and connected in parallel. The incoming gas stream is split equally between the cartridges, and the two streams are rejoined after purification but before the gas exits the baseplate. This approach allows longer contact between the nitrogen and the adsorbent, ensuring higher gas purity and eliminating a potential source of contaminants to your analyses.

A handy date wheel, included with the system, indicates the cartridge installation date and the recommended replacement date.

Super Clean gas filters provide high-purity outlet gas
Type of filter: Hydrocarbon (charcoal)
Max. Flow: 20 L/min
Outlet Gas Quality %: 99.9999%
Maximum Pressure: 11 bar/159 psi
Estimated Lifetime: 3 to 6 months

All traps measure:
10 5/8" x 1 3/4" (27 x 4.4 cm)

Each 2-position baseplate unit measures:
8" x 4" x 1 7/8" (20.3 x 10.2 x 4.8 cm)

Standard baseplate inlet/outlet fittings accept 1/4" tubing. To adapt to 1/8" tubing, order 1/4" to 1/8" tube end reducers.