Merlin Microseal Adaptor Kit for SPME Arrow

for Shimadzu 2010, 2025, and 2030 GCs
  • Eliminates septum coring and prolongs septum life.
  • Consistently low needle-insertion force.
  • Larger diameter to accept SPME Arrow (1.1 mm or 1.5 mm).
  • 400 °C max injection port temperature.
Microseals not included; must be purchased separately.
Documentation and Instructions Sheets
Instruction Sheet: Merlin Microseal User Manual

Merlin Microseal Adaptor Kit for SPME Arrow

Catalog #

Select Catalog # below
Merlin
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below
Merlin

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
23229 SPME Arrow Application Adaptor Kit (3 to 100 psi) kit for Shimadzu 2010, 2025, and 2030 GCs 1000SH Select Deselect

Catalog # 23229

Type
SPME Arrow Application Adaptor Kit (3 to 100 psi)  
Units
kit  
Instrument
for Shimadzu 2010, 2025, and 2030 GCs  
Vendor SKU
1000SH  
Includes
nut (1); adaptor (1); O-rings (4)  
Product Name
Merlin Microseal Adaptor Kit for SPME Arrow  

The advantages of the Merlin Microseal septum include elimination of septum coring, longer life, and consistently low insertion force for injections. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner.

The Restek PAL SPME Arrow is a larger-diameter SPME probe with a rugged construction that ensures longer life, higher sample throughput, and better sensitivity over traditional SPME fibers. The Merlin Microseal for SPME Arrow is available for many popular instruments and both Restek PAL SPME Arrow sizes (1.1 mm and 1.5 mm).

Microseals for both 1.1 mm and 1.5 mm SPME Arrow (3 to 100 psi) applications are available—sold separately. For use in general-purpose (3 to 100 psi), low-pressure (1 to 45 psi), and SPME fiber (3 to 100 psi) applications, a different nut/adaptor kit must be used; see Related Products.

Note that due to the relatively large diameter of Restek PAL SPME Arrows, you must modify the GC inlet using an instrument-specific conversion kit from Restek prior to use. (See www.restek.com/spme) Also note that SPME Arrow–specific Merlin Microseal adaptors, nuts, and seals are not compatible with 23-gauge (0.63 mm, 0.025") needles or probes.