25143 |
2690/2695 Pump & Autosampler PM Kit |
Waters |
|
|
Alliance 2690, 2695 |
kit |
Select
Deselect
|
Catalog # 25143
- Product Name
- 2690/2695 Pump & Autosampler PM Kit
- Instrument
- Waters
- Model Number
- Alliance 2690, 2695
- Units
- kit
- Includes
- sapphire plungers (2); seal wash plunger seals (2); head plunger seals (2); wash tube seals (4); sparge diffuser; filter insert; face seals (4); solvent reservoir 10 µm filters (4); 250 µL syringe; check valve cartridges (2); wash tube seal; seal wash tube; PTFE washer; filter retainer; lower wash seal frit; needle wash frit; TFE washer; needle assembly; gold injector seals (2); stainless steel ferrule; compression screw; seal wash face seals (2)
- Similar To
-
Waters WAT270944
|
25144 |
600 Pump PM Kit |
Waters |
|
|
600 Pump, 610 |
kit |
Select
Deselect
|
Catalog # 25144
- Product Name
- 600 Pump PM Kit
- Instrument
- Waters
- Model Number
- 600 Pump, 610
- Units
- kit
- Includes
- PerformancePLUS cartridges (4); sparge diffusers (4); Super Seals (2); solvent reservoir 10 µm filters (4); sapphire plungers (2); reference valve button; valve disk spacer; valve disk; TFE ball plug; TFE seat; ruby ball; inlet tube body assembly manifold insert; insert seal; belleville washers (2); flat washer
- Similar To
-
Waters WAT052675
|
25145 |
717 Autosampler PM Kit |
Waters |
|
|
717 Autosampler |
kit |
Select
Deselect
|
Catalog # 25145
- Product Name
- 717 Autosampler PM Kit
- Instrument
- Waters
- Model Number
- 717 Autosampler
- Units
- kit
- Includes
- seal pack assembly; tube assembly (0.020" ID); needle; needle compression screw; 0.062 stainless steel ferrule; precolumn filter assembly; filter insert; 250 µL WISP syringe
- Similar To
-
Waters WAT052669
|
25735 |
ACQUITY ISM Performance Maintenance Kit |
Waters |
|
|
ACQUITY ISM |
kit |
Select
Deselect
|
Catalog # 25735
- Product Name
- ACQUITY ISM Performance Maintenance Kit
- Instrument
- Waters
- Model Number
- ACQUITY ISM
- Units
- kit
- Includes
- mixer, plungers, check valve seals, and filters
- Similar To
-
Waters 201000286
|
25797 |
ACQUITY BSM Pump Kit |
Waters |
|
|
ACQUITY UPLC BSM |
kit |
Select
Deselect
|
Catalog # 25797
- Product Name
- ACQUITY BSM Pump Kit
- Instrument
- Waters
- Model Number
- ACQUITY UPLC BSM
- Units
- kit
- Includes
- in-line filter assembly, stainless steel frit; tube assembly, transducer to check valve; tube assembly, SSV to in-line filter; primary check valve (2); wash seal, float flanged, (2); head plunger seal kit (2); sapphire plungers, (2); air filter, pump; air filter, pump handle; mixer assembly, 50 µl; accumulator check valve, double ball & seat (2); solvent bottle filter, stainless steel (7); pump O-ring, (PTFE)
- Similar To
-
Waters 201000173
|
25798 |
ACQUITY I2V BSM Pump Kit |
Waters |
|
|
ACQUITY UPLC I2V BSM |
kit |
Select
Deselect
|
Catalog # 25798
- Product Name
- ACQUITY I2V BSM Pump Kit
- Instrument
- Waters
- Model Number
- ACQUITY UPLC I2V BSM
- Units
- kit
- Includes
- Tube assembly, SSV to I2v; transducer to check valve, tube assembly, I2v; wash seal, float flanged (2); head plunger seal kit (2); sapphire plungers (2); air filter, pump; air filter, pump handle; mixer assembly, 50 µL; filter frit cartridge, stainless steel; accumulator check valve, double ball & seat (2); check valve cartridge (2); solvent bottle filter, stainless steel (7); pump O-ring, (PTFE)
- Similar To
-
Waters 201000197
|
25799 |
ACQUITY H-Class QSM Pump Kit |
Waters |
|
|
ACQUITY H-CLASS QSM |
kit |
Select
Deselect
|
Catalog # 25799
- Product Name
- ACQUITY H-Class QSM Pump Kit
- Instrument
- Waters
- Model Number
- ACQUITY H-CLASS QSM
- Units
- kit
- Includes
- solvent bottle filter, stainless steel (5); 20 micron frit holder assembly; tube assembly, transducer to check valve; wash seal, float flanged (2); head plunger seal kit (2); sapphire plungers (2); check valve, double ball & seat (2); I2 check valve cartridge; air filter, door; pump O-ring, (PTFE); mixer assembly, 100 µL
- Similar To
-
Waters 201000233
|
26430 |
1525 Pump PM Kit |
Waters |
|
|
1525 Pump |
kit |
Select
Deselect
|
Catalog # 26430
- Product Name
- 1525 Pump PM Kit
- Instrument
- Waters
- Model Number
- 1525 Pump
- Units
- kit
- Includes
- sapphire plungers (4); check valve cartridges (8); plunger seals (4); solvent reservoir 10 µm filters (2); reference valve button; valve disk spacer; valve disk
- Similar To
-
Waters 201000114
|
26519 |
515 Pump PM Kit |
Waters |
|
|
515 Pump |
kit |
Select
Deselect
|
Catalog # 26519
- Product Name
- 515 Pump PM Kit
- Instrument
- Waters
- Model Number
- 515 Pump
- Units
- kit
- Includes
- PerformancePLUS check valves (4); sparge diffuser; solvent reservoir 10 µm filter; sapphire plungers (2); plunger seals (2); pivot inserts (2); pivot guides (2); washer (2); plunger springs (2); retaining rings (2)
- Similar To
-
Waters WAT052587
|