Rtx-Volatile Amine Columns (fused silica)

  • Unique selectivity for baseline resolution of all volatile amines.
  • Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia.
  • Highly robust phase withstands repeated water injections, resulting in longer column lifetime.
  • High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by "baking out" the column.
Ordering Notes

Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

SAVE MONEY! Get six columns for the price of five. Contact Customer Service or your local Restek representative for details!

Documentation and Instructions Sheets

Rtx-Volatile Amine Columns (fused silica)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
18076 Rtx-Volatile Amine 5 µm 0.32 mm 15 m -60 to 270/290 °C ea. Select Deselect

Catalog # 18076

Product Name
Rtx-Volatile Amine  
df (Film Thickness)
5 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
18077 Rtx-Volatile Amine 5 µm 0.32 mm 30 m -60 to 270/290 °C ea. Select Deselect

Catalog # 18077

Product Name
Rtx-Volatile Amine  
df (Film Thickness)
5 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
18078 Rtx-Volatile Amine 5 µm 0.32 mm 60 m -60 to 270/290 °C ea. Select Deselect

Catalog # 18078

Product Name
Rtx-Volatile Amine  
df (Film Thickness)
5 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  

The Rtx-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks, which allow low detection limits. The stable bonded phase yields a column that is not only retentive and highly selective for these compounds but is also very robust and able to withstand repeated water injections. Comparisons made by customers performing routine volatile amine applications have shown the Rtx-Volatile Amine column outperforms other amine-specific columns, especially for peak shape and lifetime. Each Rtx-Volatile Amine column is held to stringent quality specifications and tested with a specially designed test mix that includes basic compounds to ensure exceptional inertness, reliability, and reproducibility. These qualities assure consistent performance and make the Rtx-Volatile Amine column the best choice for volatile amines analysis.

Note: We recommend using base-deactivated fused silica guard columns and Topaz liners with Rtx-Volatile Amine columns.

Similar Phases

Agilent: CP-Volamine