Rtx-1 Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane
  • General-purpose columns for solvent impurities, arson accelerants, fuels, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, volatile organics, fragrances, and oxygenates.
  • Long lifetime and very low bleed at high operating temperatures.
  • Equivalent to USP G1, G2, G9, G38 phases.
  • Temperature Range: -60 °C to 350 °C.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes

Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

SAVE MONEY! Get six columns for the price of five. Contact Customer Service or your local Restek representative for details!

Documentation and Instructions Sheets

Rtx-1 Columns (fused silica)

Catalog # 10180

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10180 Rtx-1 5.00 µm 0.32 mm 60 m -60 to 260/280 °C ea. Select Deselect

Catalog # 10180

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 260/280 °C  
Units
ea.  
Similar To
Agilent 123-1065
Agilent 19091Z-716
10105 Rtx-1 0.10 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10105

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-1011
Agilent 19091Z-331
Phenomenex 7EG-G001-02
10106 Rtx-1 0.10 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10106

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-1011
10107 Rtx-1 0.10 µm 0.53 mm 15 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10107

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10108 Rtx-1 0.10 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10108

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-1031
Agilent 19091Z-333
Phenomenex 7HG-G001-02
10109 Rtx-1 0.10 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10109

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-1031
Agilent 19091Z-313
10110 Rtx-1 0.10 µm 0.53 mm 30 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10110

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 125-1039
Phenomenex 7HK-G001-02
10111 Rtx-1 0.10 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10111

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-1061
Phenomenex 7KG-G001-02
10112 Rtx-1 0.10 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10112

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-1061
Phenomenex 7KM-G001-02
10114 Rtx-1 0.10 µm 0.25 mm 105 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10114

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
105 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10120 Rtx-1 0.25 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10120

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-1012
Agilent 19091Z-431
Phenomenex 7EG-G001-11
10121 Rtx-1 0.25 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10121

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-1012
Agilent 19091Z-411
Phenomenex 7EM-G001-11
10122 Rtx-1 0.25 µm 0.53 mm 15 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10122

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 125-101K
10123 Rtx-1 0.25 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10123

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-1032
Agilent 19091Z-433
Phenomenex 7HG-G001-11
10123-600 Rtx-1 0.25 µm 0.25 mm 30 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 10123-600

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
10124 Rtx-1 0.25 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10124

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-1032
Agilent 19091Z-413
Phenomenex 7HM-G001-11
10125 Rtx-1 0.25 µm 0.53 mm 30 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10125

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 125-103K
10126 Rtx-1 0.25 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10126

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-1062
Agilent 19091Z-436
Phenomenex 7KG-G001-11
10127 Rtx-1 0.25 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10127

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-1062
Agilent 19091Z-416
Phenomenex 7KM-G001-11
10128 Rtx-1 0.25 µm 0.53 mm 60 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10128

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10129 Rtx-1 0.25 µm 0.25 mm 105 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10129

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
105 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10135 Rtx-1 0.50 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10135

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-101E
10136 Rtx-1 0.50 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10136

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-101E
10137 Rtx-1 0.50 µm 0.53 mm 15 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10137

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-1017
Phenomenex 7EK-G001-17
10138 Rtx-1 0.50 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10138

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-103E
Phenomenex 7HG-G001-17
10139 Rtx-1 0.50 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10139

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-103E
Phenomenex 7HM-G001-17
10140 Rtx-1 0.50 µm 0.53 mm 30 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10140

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-1037
Phenomenex 7HK-G001-17
10141 Rtx-1 0.50 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10141

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-106E
10142 Rtx-1 0.50 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10142

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-106E
10143 Rtx-1 0.50 µm 0.53 mm 60 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10143

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10144 Rtx-1 0.50 µm 0.25 mm 105 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10144

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
105 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10150 Rtx-1 1.00 µm 0.25 mm 15 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10150

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 122-1013
Agilent 19091Z-231
Phenomenex 7EG-G001-22
10151 Rtx-1 1.00 µm 0.32 mm 15 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10151

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 123-1013
Agilent 19091Z-211
Phenomenex 7EM-G001-22
10152 Rtx-1 1.00 µm 0.53 mm 15 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10152

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-101J
10153 Rtx-1 1.00 µm 0.25 mm 30 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10153

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 122-1033
Agilent 19091Z-233
Phenomenex 7HG-G001-22
10154 Rtx-1 1.00 µm 0.32 mm 30 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10154

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 123-1033
Agilent 19091Z-213
Phenomenex 7HM-G001-22
10154-600 Rtx-1 1.00 µm 0.32 mm 30 m -60 to 320/340 °C 6-pk. Select Deselect

Catalog # 10154-600

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
6-pk.  
10155 Rtx-1 1.00 µm 0.53 mm 30 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10155

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-103J
10156 Rtx-1 1.00 µm 0.25 mm 60 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10156

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 122-1063
Agilent 19091Z-236
Phenomenex 7KG-G001-22
10157 Rtx-1 1.00 µm 0.32 mm 60 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10157

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 123-1063
Agilent 19091Z-216
Phenomenex 7KM-G001-22
10158 Rtx-1 1.00 µm 0.53 mm 60 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10158

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-106J
10159 Rtx-1 1.00 µm 0.25 mm 105 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10159

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
105 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10160 Rtx-1 1.00 µm 0.32 mm 105 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10160

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
105 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10166 Rtx-1 1.50 µm 0.32 mm 15 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10166

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10167 Rtx-1 1.50 µm 0.53 mm 15 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10167

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-1012
Agilent 19095Z-321
Phenomenex 7EK-G001-28
10169 Rtx-1 1.50 µm 0.32 mm 30 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10169

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10170 Rtx-1 1.50 µm 0.53 mm 30 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10170

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-1032
Agilent 19095Z-323
Phenomenex 7HK-G001-28
10172 Rtx-1 1.50 µm 0.32 mm 60 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10172

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 123-106B
10173 Rtx-1 1.50 µm 0.53 mm 60 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10173

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-1062
Phenomenex 7KK-G001-28
10175 Rtx-1 1.50 µm 0.32 mm 105 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10175

Product Name
Rtx-1  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
105 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10176 Rtx-1 5.00 µm 0.32 mm 15 m -60 to 260/280 °C ea. Select Deselect

Catalog # 10176

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 260/280 °C  
Units
ea.  
Similar To
Agilent 123-1015
10177 Rtx-1 5.00 µm 0.53 mm 15 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10177

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-1015
Agilent 19095Z-621
Phenomenex 7EK-G001-39
10178 Rtx-1 5.00 µm 0.32 mm 30 m -60 to 260/280 °C ea. Select Deselect

Catalog # 10178

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 260/280 °C  
Units
ea.  
Similar To
Agilent 123-1035
Agilent 19091Z-713
Phenomenex 7HM-G001-39
10179 Rtx-1 5.00 µm 0.53 mm 30 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10179

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-1035
Agilent 19095Z-623
Phenomenex 7HK-G001-39
10179-600 Rtx-1 5.00 µm 0.53 mm 30 m -60 to 270/290 °C 6-pk. Select Deselect

Catalog # 10179-600

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
6-pk.  
10180-600 Rtx-1 5.00 µm 0.32 mm 60 m -60 to 260/280 °C 6-pk. Select Deselect

Catalog # 10180-600

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 260/280 °C  
Units
6-pk.  
10181 Rtx-1 3.00 µm 0.32 mm 15 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10181

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
Similar To
Agilent 123-1014
10182 Rtx-1 3.00 µm 0.53 mm 15 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10182

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-1014
Agilent 19095Z-421
Phenomenex 7EK-G001-36
10183 Rtx-1 5.00 µm 0.53 mm 60 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10183

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-1065
Agilent 19095Z-626
10184 Rtx-1 3.00 µm 0.32 mm 30 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10184

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
Similar To
Agilent 123-1034
Agilent 19091Z-513
10185 Rtx-1 3.00 µm 0.53 mm 30 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10185

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-1034
Agilent 19095Z-423
Phenomenex 7HK-G001-36
10187 Rtx-1 3.00 µm 0.32 mm 60 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10187

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
Similar To
Agilent 123-1064
Phenomenex 7KM-G001-36
10188 Rtx-1 3.00 µm 0.53 mm 60 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10188

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-1064
10189 Rtx-1 3.00 µm 0.53 mm 105 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10189

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
105 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
10190 Rtx-1 3.00 µm 0.32 mm 105 m -60 to 260/280 °C ea. Select Deselect

Catalog # 10190

Product Name
Rtx-1  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
105 m  
Temp Limits
-60 to 260/280 °C  
Units
ea.  
10191 Rtx-1 7.00 µm 0.53 mm 15 m -60 to 240/260 °C ea. Select Deselect

Catalog # 10191

Product Name
Rtx-1  
df (Film Thickness)
7.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 240/260 °C  
Units
ea.  
10192 Rtx-1 7.00 µm 0.53 mm 30 m -60 to 240/260 °C ea. Select Deselect

Catalog # 10192

Product Name
Rtx-1  
df (Film Thickness)
7.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 240/260 °C  
Units
ea.  
10193 Rtx-1 7.00 µm 0.53 mm 60 m -60 to 240/260 °C ea. Select Deselect

Catalog # 10193

Product Name
Rtx-1  
df (Film Thickness)
7.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 240/260 °C  
Units
ea.  
10194 Rtx-1 5.00 µm 0.53 mm 105 m -60 to 240/260 °C ea. Select Deselect

Catalog # 10194

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
105 m  
Temp Limits
-60 to 240/260 °C  
Units
ea.  
10198 Rtx-1 4.00 µm 0.32 mm 30 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10198

Product Name
Rtx-1  
df (Film Thickness)
4.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
Similar To
Agilent 19091Z-613
40101 Rtx-1 0.20 µm 0.18 mm 10 m -60 to 330/350 °C ea. Select Deselect

Catalog # 40101

Product Name
Rtx-1  
df (Film Thickness)
0.20 µm  
ID
0.18 mm  
Length
10 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 121-101A
40102 Rtx-1 0.20 µm 0.18 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 40102

Product Name
Rtx-1  
df (Film Thickness)
0.20 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 121-102A
40103 Rtx-1 0.20 µm 0.18 mm 40 m -60 to 330/350 °C ea. Select Deselect

Catalog # 40103

Product Name
Rtx-1  
df (Film Thickness)
0.20 µm  
ID
0.18 mm  
Length
40 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
40110 Rtx-1 0.40 µm 0.18 mm 10 m -60 to 330/340 °C ea. Select Deselect

Catalog # 40110

Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
ID
0.18 mm  
Length
10 m  
Temp Limits
-60 to 330/340 °C  
Units
ea.  
Similar To
Agilent 121-1013
40111 Rtx-1 0.40 µm 0.18 mm 20 m -60 to 330/340 °C ea. Select Deselect

Catalog # 40111

Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/340 °C  
Units
ea.  
Similar To
Agilent 121-1023
40112 Rtx-1 0.40 µm 0.18 mm 40 m -60 to 330/340 °C ea. Select Deselect

Catalog # 40112

Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
ID
0.18 mm  
Length
40 m  
Temp Limits
-60 to 330/340 °C  
Units
ea.  
Similar To
Agilent 121-1043
41101 Rtx-1 0.10 µm 0.10 mm 10 m -60 to 330/350 °C ea. Select Deselect

Catalog # 41101

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
10 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 127-1012
41102 Rtx-1 0.10 µm 0.10 mm 20 m -60 to 330/360 °C ea. Select Deselect

Catalog # 41102

Product Name
Rtx-1  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
20 m  
Temp Limits
-60 to 330/360 °C  
Units
ea.  
Similar To
Agilent 127-1022
41103 Rtx-1 0.40 µm 0.10 mm 10 m -60 to 330/340 °C ea. Select Deselect

Catalog # 41103

Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
ID
0.10 mm  
Length
10 m  
Temp Limits
-60 to 330/340 °C  
Units
ea.  
Similar To
Agilent 127-1013
41104 Rtx-1 0.40 µm 0.10 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 41104

Product Name
Rtx-1  
df (Film Thickness)
0.40 µm  
ID
0.10 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 127-1023

Similar Phases

Phenomenex: ZB-1

Agilent: CP-Sil 5 CB, DB-1, HP-1