Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Rtx-5 (G27) Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane
  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Equivalent to USP G27 and G36 phases.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes
Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

SAVE MONEY! Get six columns for the price of five. Contact Customer Service or your local Restek representative for details!
Documentation and Instructions Sheets

Rtx-5 (G27) Columns (fused silica)

Catalog # 10223-600

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10223-600 Rtx-5 0.25 µm 0.25 mm 30 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 10223-600

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
10205 Rtx-5 0.10 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10205

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-5011
Phenomenex 7EG-G002-02
10206 Rtx-5 0.10 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10206

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-5011
Phenomenex 7EM-G002-02
Scion/Bruker/Varian CP7731
10207 Rtx-5 0.10 µm 0.53 mm 15 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10207

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10208 Rtx-5 0.10 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10208

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-5031
Agilent 19091J-333
Phenomenex 7HG-G002-02
Scion/Bruker/Varian CP7711
10209 Rtx-5 0.10 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10209

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-5031
Agilent 19091J-313
Phenomenex 7HM-G002-02
Scion/Bruker/Varian CP7741
Scion/Bruker/Varian CP8791
10210 Rtx-5 0.10 µm 0.53 mm 30 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10210

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10211 Rtx-5 0.10 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10211

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-5061
Phenomenex 7KG-G002-02
Scion/Bruker/Varian CP7721
10220 Rtx-5 0.25 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10220

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-5012
Agilent 19091J-431
Phenomenex 7EG-G002-11
Scion/Bruker/Varian CP8511
10220-600 Rtx-5 0.25 µm 0.25 mm 15 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 10220-600

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
10221 Rtx-5 0.25 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10221

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-5012
Agilent 19091J-411
Phenomenex 7EM-G002-11
Scion/Bruker/Varian CP8531
10222 Rtx-5 0.25 µm 0.53 mm 15 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10222

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 125-501K
10223 Rtx-5 0.25 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10223

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-5032
Agilent 19091J-433
Phenomenex 7HG-G002-11
Scion/Bruker/Varian CP8751
10224 Rtx-5 0.25 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10224

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-5032
Agilent 19091J-413
Phenomenex 7HM-G002-11
Scion/Bruker/Varian CP8752
10225 Rtx-5 0.25 µm 0.53 mm 30 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10225

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 125-503K
10226 Rtx-5 0.25 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10226

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-5062
Agilent 19091J-436
Phenomenex 7KG-G002-11
Scion/Bruker/Varian CP8753
10226-600 Rtx-5 0.25 µm 0.25 mm 60 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 10226-600

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
10227 Rtx-5 0.25 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10227

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-5062
Agilent 19091J-416
Phenomenex 7KM-G002-11
Scion/Bruker/Varian CP8754
10228 Rtx-5 0.25 µm 0.53 mm 60 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10228

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10229 Rtx-5 0.25 µm 0.25 mm 105 m -60 to 320/350 °C ea. Select Deselect

Catalog # 10229

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
105 m  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
10235 Rtx-5 0.50 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10235

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-501E
Phenomenex 7EG-G002-17
10235-600 Rtx-5 0.50 µm 0.25 mm 15 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 10235-600

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
10236 Rtx-5 0.50 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10236

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-501E
10237 Rtx-5 0.50 µm 0.53 mm 15 m -60 to 320/330 °C ea. Select Deselect

Catalog # 10237

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 320/330 °C  
Units
ea.  
Similar To
Agilent 125-5017
Phenomenex 7EK-G002-17
10238 Rtx-5 0.50 µm 0.25 mm 30 m -60 to 330 °C ea. Select Deselect

Catalog # 10238

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330 °C  
Units
ea.  
Similar To
Agilent 122-503E
Phenomenex 7HG-G002-17
Scion/Bruker/Varian CP7759
10239 Rtx-5 0.50 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10239

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-503E
Agilent 19091J-113
Phenomenex 7HM-G002-17
Scion/Bruker/Varian CP7779
10240 Rtx-5 0.50 µm 0.53 mm 30 m -60 to 320/330 °C ea. Select Deselect

Catalog # 10240

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/330 °C  
Units
ea.  
Similar To
Agilent 125-5037
Phenomenex 7HK-G002-17
Scion/Bruker/Varian CP8716
10241 Rtx-5 0.50 µm 0.25 mm 60 m -60 to 320/350 °C ea. Select Deselect

Catalog # 10241

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
Similar To
Agilent 122-506E
Phenomenex 7KG-G002-17
Scion/Bruker/Varian CP7769
10242 Rtx-5 0.50 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 10242

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-506E
10243 Rtx-5 0.50 µm 0.53 mm 60 m -60 to 300/330 °C ea. Select Deselect

Catalog # 10243

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 300/330 °C  
Units
ea.  
10244 Rtx-5 0.50 µm 0.25 mm 105 m -60 to 320/350 °C ea. Select Deselect

Catalog # 10244

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
105 m  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
10250 Rtx-5 1.00 µm 0.25 mm 15 m -60 to 325/340 °C ea. Select Deselect

Catalog # 10250

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 325/340 °C  
Units
ea.  
Similar To
Agilent 122-5013
Agilent 19091J-231
Phenomenex 7EG-G002-22
Scion/Bruker/Varian CP8521
10251 Rtx-5 1.00 µm 0.32 mm 15 m -60 to 325/350 °C ea. Select Deselect

Catalog # 10251

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 325/350 °C  
Units
ea.  
Similar To
Agilent 123-5013
Agilent 19091J-211
Phenomenex 7EM-G002-22
Scion/Bruker/Varian CP8541
10252 Rtx-5 1.00 µm 0.53 mm 15 m -60 to 320/330 °C ea. Select Deselect

Catalog # 10252

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 320/330 °C  
Units
ea.  
Similar To
Agilent 125-501J
Scion/Bruker/Varian CP7626
10253 Rtx-5 1.00 µm 0.25 mm 30 m -60 to 325/340 °C ea. Select Deselect

Catalog # 10253

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 325/340 °C  
Units
ea.  
Similar To
Agilent 122-5033
Agilent 19091J-233
Phenomenex 7HG-G002-22
Scion/Bruker/Varian CP8771
10254 Rtx-5 1.00 µm 0.32 mm 30 m -60 to 325/350 °C ea. Select Deselect

Catalog # 10254

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 325/350 °C  
Units
ea.  
Similar To
Agilent 123-5033
Agilent 19091J-213
Phenomenex 7HM-G002-22
Scion/Bruker/Varian CP7761
Scion/Bruker/Varian CP8761
10255 Rtx-5 1.00 µm 0.53 mm 30 m -60 to 320/330 °C ea. Select Deselect

Catalog # 10255

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/330 °C  
Units
ea.  
Similar To
Agilent 125-503J
Scion/Bruker/Varian CP7636
10255-600 Rtx-5 1.00 µm 0.53 mm 30 m -60 to 320/330 °C 6-pk. Select Deselect

Catalog # 10255-600

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 320/330 °C  
Units
6-pk.  
10256 Rtx-5 1.00 µm 0.25 mm 60 m -60 to 320/340 °C ea. Select Deselect

Catalog # 10256

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 122-5063
Agilent 19091J-236
Phenomenex 7KG-G002-22
Scion/Bruker/Varian C8781
10257 Rtx-5 1.00 µm 0.32 mm 60 m -60 to 320/350 °C ea. Select Deselect

Catalog # 10257

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
Similar To
Agilent 123-5063
Agilent 19091J-216
Phenomenex 7KM-G002-22
Scion/Bruker/Varian CP8871
10257-600 Rtx-5 1.00 µm 0.32 mm 60 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 10257-600

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
10258 Rtx-5 1.00 µm 0.53 mm 60 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10258

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10260 Rtx-5 1.00 µm 0.32 mm 105 m -60 to 310/350 °C ea. Select Deselect

Catalog # 10260

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
105 m  
Temp Limits
-60 to 310/350 °C  
Units
ea.  
10266 Rtx-5 1.50 µm 0.32 mm 15 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10266

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10267 Rtx-5 1.50 µm 0.53 mm 15 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10267

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-5012
Agilent 19095J-321
Phenomenex 7EK-G002-28
Scion/Bruker/Varian CP8678
10269 Rtx-5 1.50 µm 0.32 mm 30 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10269

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 123-503B
10270 Rtx-5 1.50 µm 0.53 mm 30 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10270

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
Similar To
Agilent 125-5032
Agilent 19095J-323
Phenomenex 7HK-G002-28
Scion/Bruker/Varian CP7631
Scion/Bruker/Varian CP8763
10272 Rtx-5 1.50 µm 0.32 mm 60 m -60 to 310/330 °C ea. Select Deselect

Catalog # 10272

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10273 Rtx-5 1.50 µm 0.53 mm 60 m -60 to 300/320 °C ea. Select Deselect

Catalog # 10273

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 300/320 °C  
Units
ea.  
Similar To
Agilent 125-5062
Phenomenex 7KK-G002-28
Scion/Bruker/Varian CP8796
10275 Rtx-5 1.50 µm 0.32 mm 105 m -60 to 300/320 °C ea. Select Deselect

Catalog # 10275

Product Name
Rtx-5  
df (Film Thickness)
1.50 µm  
ID
0.32 mm  
Length
105 m  
Temp Limits
-60 to 300/320 °C  
Units
ea.  
10277 Rtx-5 5.00 µm 0.53 mm 15 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10277

Product Name
Rtx-5  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-5015
Agilent 19095J-621
10279 Rtx-5 5.00 µm 0.53 mm 30 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10279

Product Name
Rtx-5  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-5035
Agilent 19095J-623
Phenomenex 7HK-G002-39
Scion/Bruker/Varian CP8756
10279-600 Rtx-5 5.00 µm 0.53 mm 30 m -60 to 270/290 °C 6-pk. Select Deselect

Catalog # 10279-600

Product Name
Rtx-5  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
6-pk.  
10281 Rtx-5 3.00 µm 0.32 mm 15 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10281

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
10282 Rtx-5 3.00 µm 0.53 mm 15 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10282

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
10283 Rtx-5 5.00 µm 0.53 mm 60 m -60 to 260/290 °C ea. Select Deselect

Catalog # 10283

Product Name
Rtx-5  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 260/290 °C  
Units
ea.  
Similar To
Agilent 125-5065
10284 Rtx-5 3.00 µm 0.32 mm 30 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10284

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
10285 Rtx-5 3.00 µm 0.53 mm 30 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10285

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Similar To
Agilent 125-5034
Phenomenex 7HK-G002-36
10285-600 Rtx-5 3.00 µm 0.53 mm 30 m -60 to 270/290 °C 6-pk. Select Deselect

Catalog # 10285-600

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 270/290 °C  
Units
6-pk.  
10287 Rtx-5 3.00 µm 0.32 mm 60 m -60 to 280/300 °C ea. Select Deselect

Catalog # 10287

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 280/300 °C  
Units
ea.  
10288 Rtx-5 3.00 µm 0.53 mm 60 m -60 to 270/290 °C ea. Select Deselect

Catalog # 10288

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
10290 Rtx-5 3.00 µm 0.32 mm 105 m -60 to 260/300 °C ea. Select Deselect

Catalog # 10290

Product Name
Rtx-5  
df (Film Thickness)
3.00 µm  
ID
0.32 mm  
Length
105 m  
Temp Limits
-60 to 260/300 °C  
Units
ea.  
40201 Rtx-5 0.20 µm 0.18 mm 10 m -60 to 325/340 °C ea. Select Deselect

Catalog # 40201

Product Name
Rtx-5  
df (Film Thickness)
0.20 µm  
ID
0.18 mm  
Length
10 m  
Temp Limits
-60 to 325/340 °C  
Units
ea.  
40202 Rtx-5 0.20 µm 0.18 mm 20 m -60 to 325/340 °C ea. Select Deselect

Catalog # 40202

Product Name
Rtx-5  
df (Film Thickness)
0.20 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 325/340 °C  
Units
ea.  
40203 Rtx-5 0.20 µm 0.18 mm 40 m -60 to 325/340 °C ea. Select Deselect

Catalog # 40203

Product Name
Rtx-5  
df (Film Thickness)
0.20 µm  
ID
0.18 mm  
Length
40 m  
Temp Limits
-60 to 325/340 °C  
Units
ea.  
40210 Rtx-5 0.40 µm 0.18 mm 10 m -60 to 315/330 °C ea. Select Deselect

Catalog # 40210

Product Name
Rtx-5  
df (Film Thickness)
0.40 µm  
ID
0.18 mm  
Length
10 m  
Temp Limits
-60 to 315/330 °C  
Units
ea.  
Similar To
Agilent 121-5013
40211 Rtx-5 0.40 µm 0.18 mm 20 m -60 to 315/330 °C ea. Select Deselect

Catalog # 40211

Product Name
Rtx-5  
df (Film Thickness)
0.40 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 315/330 °C  
Units
ea.  
Similar To
Agilent 121-5023
40212 Rtx-5 0.40 µm 0.18 mm 40 m -60 to 315/330 °C ea. Select Deselect

Catalog # 40212

Product Name
Rtx-5  
df (Film Thickness)
0.40 µm  
ID
0.18 mm  
Length
40 m  
Temp Limits
-60 to 315/330 °C  
Units
ea.  
Similar To
Agilent 121-5043
41201 Rtx-5 0.10 µm 0.10 mm 10 m -60 to 330/350 °C ea. Select Deselect

Catalog # 41201

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
10 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 127-5012
Scion/Bruker/Varian CP7315
41202 Rtx-5 0.10 µm 0.10 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 41202

Product Name
Rtx-5  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 127-5022
41204 Rtx-5 0.40 µm 0.10 mm 20 m -60 to 320/340 °C ea. Select Deselect

Catalog # 41204

Product Name
Rtx-5  
df (Film Thickness)
0.40 µm  
ID
0.10 mm  
Length
20 m  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
Similar To
Agilent 127-5023

The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the Rtx-5 polymer, providing a tight monomodal distribution and extremely low bleed.
Similar Phases

Phenomenex: ZB-5

Agilent: CP-Sil 8 CB, DB-5, HP-5