Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Stabilwax Columns (fused silica)

polar phase; Crossbond polyethylene glycol
  • Low-bleed PEG column ensures long column lifetimes.
  • Temperature range: 40 °C to 260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.
  • Some dimensions also available as Integra-Guard columns — a guard and analytical column in one to eliminate connection problems!
Ordering Notes
Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

SAVE MONEY! Get six columns for the price of five. Contact Customer Service or your local Restek representative for details!
Documentation and Instructions Sheets

Stabilwax Columns (fused silica)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10605 Stabilwax 0.10 µm 0.25 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10605

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10608 Stabilwax 0.10 µm 0.25 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10608

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10609 Stabilwax 0.10 µm 0.32 mm 30 m 40 to 250 °C ea. Select Deselect

Catalog # 10609

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
40 to 250 °C  
Units
ea.  
10610 Stabilwax 0.10 µm 0.53 mm 30 m 40 to 250 °C ea. Select Deselect

Catalog # 10610

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 250 °C  
Units
ea.  
10611 Stabilwax 0.10 µm 0.25 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10611

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10620 Stabilwax 0.25 µm 0.25 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10620

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 122-7312
Agilent 19091N-131
Scion/Bruker/Varian CP8513
10621 Stabilwax 0.25 µm 0.32 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10621

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 123-7312
Agilent 19091N-111
Scion/Bruker/Varian CP8543
10622 Stabilwax 0.25 µm 0.53 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10622

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10623 Stabilwax 0.25 µm 0.25 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10623

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 122-7332
Agilent 19091N-133
Scion/Bruker/Varian CP8713
10623-600 Stabilwax 0.25 µm 0.25 mm 30 m 40 to 250/260 °C 6-pk. Select Deselect

Catalog # 10623-600

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
6-pk.  
10624 Stabilwax 0.25 µm 0.32 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10624

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 123-7332
Agilent 19091N-113
Scion/Bruker/Varian CP8843
10625 Stabilwax 0.25 µm 0.53 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10625

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10626 Stabilwax 0.25 µm 0.25 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10626

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 122-7362
Agilent 19091N-136
Scion/Bruker/Varian CP8723
10627 Stabilwax 0.25 µm 0.32 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10627

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 123-7362
Agilent 19091N-116
Scion/Bruker/Varian CP8853
10628 Stabilwax 0.25 µm 0.53 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10628

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10635 Stabilwax 0.50 µm 0.25 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10635

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 122-7313
Agilent 19091N-231
Scion/Bruker/Varian CP8523
10636 Stabilwax 0.50 µm 0.32 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10636

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 123-7313
Agilent 19091N-211
Scion/Bruker/Varian CP8553
10637 Stabilwax 0.50 µm 0.53 mm 15 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10637

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10638 Stabilwax 0.50 µm 0.25 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10638

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 122-7333
Agilent 19091N-233
Scion/Bruker/Varian CP8746
10639 Stabilwax 0.50 µm 0.32 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10639

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 123-7333
Agilent 19091N-213
Scion/Bruker/Varian CP8763
10640 Stabilwax 0.50 µm 0.53 mm 30 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10640

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10641 Stabilwax 0.50 µm 0.25 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10641

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 122-7363
Agilent 19091N-236
Scion/Bruker/Varian CP8748
10642 Stabilwax 0.50 µm 0.32 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10642

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
Similar To
Agilent 123-7363
Agilent 19091N-216
Scion/Bruker/Varian CP8773
10643 Stabilwax 0.50 µm 0.53 mm 60 m 40 to 250/260 °C ea. Select Deselect

Catalog # 10643

Product Name
Stabilwax  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
10651 Stabilwax 1.00 µm 0.32 mm 15 m 40 to 240/250 °C ea. Select Deselect

Catalog # 10651

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
40 to 240/250 °C  
Units
ea.  
Similar To
Agilent 123-7314
10652 Stabilwax 1.00 µm 0.53 mm 15 m 40 to 240/250 °C ea. Select Deselect

Catalog # 10652

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
40 to 240/250 °C  
Units
ea.  
Similar To
Agilent 125-7312
10654 Stabilwax 1.00 µm 0.32 mm 30 m 40 to 240/260 °C ea. Select Deselect

Catalog # 10654

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
40 to 240/260 °C  
Units
ea.  
Similar To
Agilent 123-7334
10655 Stabilwax 1.00 µm 0.53 mm 30 m 40 to 240/250 °C ea. Select Deselect

Catalog # 10655

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 240/250 °C  
Units
ea.  
Similar To
Agilent 125-7332
10655-600 Stabilwax 1.00 µm 0.53 mm 30 m 40 to 240/250 °C 6-pk. Select Deselect

Catalog # 10655-600

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 240/250 °C  
Units
6-pk.  
10657 Stabilwax 1.00 µm 0.32 mm 60 m 40 to 240/260 °C ea. Select Deselect

Catalog # 10657

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
40 to 240/260 °C  
Units
ea.  
Similar To
Agilent 123-7364
10658 Stabilwax 1.00 µm 0.53 mm 60 m 40 to 240/250 °C ea. Select Deselect

Catalog # 10658

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
40 to 240/250 °C  
Units
ea.  
Similar To
Agilent 125-7362
10666 Stabilwax 1.50 µm 0.53 mm 15 m 40 to 230/240 °C ea. Select Deselect

Catalog # 10666

Product Name
Stabilwax  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
40 to 230/240 °C  
Units
ea.  
10667 Stabilwax 2.00 µm 0.53 mm 15 m 40 to 220/230 °C ea. Select Deselect

Catalog # 10667

Product Name
Stabilwax  
df (Film Thickness)
2.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
40 to 220/230 °C  
Units
ea.  
Similar To
Agilent 125-7314
10669 Stabilwax 1.50 µm 0.53 mm 30 m 40 to 230/240 °C ea. Select Deselect

Catalog # 10669

Product Name
Stabilwax  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 230/240 °C  
Units
ea.  
Similar To
Agilent 125-7333
10670 Stabilwax 2.00 µm 0.53 mm 30 m 40 to 220/230 °C ea. Select Deselect

Catalog # 10670

Product Name
Stabilwax  
df (Film Thickness)
2.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
40 to 220/230 °C  
Units
ea.  
Similar To
Agilent 125-7334
10672 Stabilwax 1.50 µm 0.53 mm 60 m 40 to 230/240 °C ea. Select Deselect

Catalog # 10672

Product Name
Stabilwax  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
40 to 230/240 °C  
Units
ea.  
Similar To
Agilent 125-7363
15102 Stabilwax 0.10 µm 0.10 mm 1.1 m (±3 cm) 40 to 250/250 °C ea. Select Deselect

Catalog # 15102

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
1.1 m (±3 cm)  
Temp Limits
40 to 250/250 °C  
Units
ea.  
40602 Stabilwax 0.18 µm 0.18 mm 20 m 40 to 250 °C ea. Select Deselect

Catalog # 40602

Product Name
Stabilwax  
df (Film Thickness)
0.18 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
40 to 250 °C  
Units
ea.  
42601 Stabilwax 0.10 µm 0.10 mm 10 m 40 to 250/260 °C ea. Select Deselect

Catalog # 42601

Product Name
Stabilwax  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
10 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
43830 Stabilwax 0.15 µm 0.15 mm 10 m 40 to 250/260 °C ea. Select Deselect

Catalog # 43830

Product Name
Stabilwax  
df (Film Thickness)
0.15 µm  
ID
0.15 mm  
Length
10 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  
43831 Stabilwax 0.15 µm 0.15 mm 20 m 40 to 250/260 °C ea. Select Deselect

Catalog # 43831

Product Name
Stabilwax  
df (Film Thickness)
0.15 µm  
ID
0.15 mm  
Length
20 m  
Temp Limits
40 to 250/260 °C  
Units
ea.  

Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column lifetimes, even when programming repeatedly up to 260 °C. The bonding mechanism of the column also produces polar compound retention times that do not shift, as is often observed on other wax-type columns. In addition, this bonding mechanism produces a column that can be rejuvenated by solvent washing. Stabilwax columns are used for a wide range of compounds and matrices including FAMEs, flavor compounds, essential oils, solvents, aromatics (including xylene isomers), acrolein/acrylonitrile (EPA 603), and oxygenated compounds. Also used for purity testing of chemicals and analyzing alcoholic beverages.
Similar Phases

Agilent: HP-INNOWax

Phenomenex: ZB-WAXplus

Quadrex: 007-CW

Supelco/Millipore Sigma: SUPELCOWAX 10