11005 |
Stabilwax-DA |
0.10 µm |
0.25 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11005
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.10 µm
- ID
- 0.25 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11007 |
Stabilwax-DA |
0.10 µm |
0.53 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11007
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.10 µm
- ID
- 0.53 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11008 |
Stabilwax-DA |
0.10 µm |
0.25 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11008
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.10 µm
- ID
- 0.25 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11009 |
Stabilwax-DA |
0.10 µm |
0.32 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11009
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.10 µm
- ID
- 0.32 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11020 |
Stabilwax-DA |
0.25 µm |
0.25 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11020
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.25 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 122-3212
Agilent 19091F-431
Grace 13782
Grace 8635135
Phenomenex 7EG-G009-11
|
11021 |
Stabilwax-DA |
0.25 µm |
0.32 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11021
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.32 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 123-3212
Agilent 19091F-411
Grace 13886
Grace 8635170
Phenomenex 7EM-G009-11
|
11022 |
Stabilwax-DA |
0.25 µm |
0.53 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11022
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.53 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11023 |
Stabilwax-DA |
0.25 µm |
0.25 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11023
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.25 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 122-3232
Agilent 19019F-433
Grace 13783
Grace 14537
Grace 5121925
Grace 5122065
Grace 8635247
Phenomenex 7HG-G009-11
Scion/Bruker/Varian CP7717
|
11024 |
Stabilwax-DA |
0.25 µm |
0.32 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11024
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.32 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 123-3232
Agilent 19091F-413
Grace 13785
Grace 14539
Grace 5122066
Grace 8635266
Phenomenex 7HM-G009-11
|
11025 |
Stabilwax-DA |
0.25 µm |
0.53 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11025
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.53 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 125-3231
|
11026 |
Stabilwax-DA |
0.25 µm |
0.25 mm |
60 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11026
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.25 mm
- Length
- 60 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 122-3262
Grace 13784
Grace 14547
Grace 5122068
Grace 8635345
Phenomenex 7KG-G009-11
Scion/Bruker/Varian CP7727
|
11027 |
Stabilwax-DA |
0.25 µm |
0.32 mm |
60 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11027
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.32 mm
- Length
- 60 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 123-3262
Grace 13786
Grace 8635359
|
11028 |
Stabilwax-DA |
0.25 µm |
0.53 mm |
60 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11028
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.25 µm
- ID
- 0.53 mm
- Length
- 60 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11035 |
Stabilwax-DA |
0.50 µm |
0.25 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11035
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.25 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11036 |
Stabilwax-DA |
0.50 µm |
0.32 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11036
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.32 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11037 |
Stabilwax-DA |
0.50 µm |
0.53 mm |
15 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11037
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.53 mm
- Length
- 15 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 125-3217
|
11038 |
Stabilwax-DA |
0.50 µm |
0.25 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11038
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.25 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 122-3233
|
11039 |
Stabilwax-DA |
0.50 µm |
0.32 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11039
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.32 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 123-3233
Phenomenex 7HM-G009-17
|
11040 |
Stabilwax-DA |
0.50 µm |
0.53 mm |
30 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11040
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.53 mm
- Length
- 30 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 125-3237
|
11041 |
Stabilwax-DA |
0.50 µm |
0.25 mm |
60 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11041
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.25 mm
- Length
- 60 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 122-3263
|
11042 |
Stabilwax-DA |
0.50 µm |
0.32 mm |
60 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11042
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.32 mm
- Length
- 60 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
- Similar To
-
Agilent 123-3263
|
11043 |
Stabilwax-DA |
0.50 µm |
0.53 mm |
60 m |
|
|
40 to 250/260 °C |
ea. |
Select
Deselect
|
Catalog # 11043
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 0.50 µm
- ID
- 0.53 mm
- Length
- 60 m
- Temp Limits
- 40 to 250/260 °C
- Units
- ea.
|
11051 |
Stabilwax-DA |
1.00 µm |
0.32 mm |
15 m |
|
|
40 to 240/250 °C |
ea. |
Select
Deselect
|
Catalog # 11051
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.00 µm
- ID
- 0.32 mm
- Length
- 15 m
- Temp Limits
- 40 to 240/250 °C
- Units
- ea.
- Similar To
-
Agilent 123-3214
|
11052 |
Stabilwax-DA |
1.00 µm |
0.53 mm |
15 m |
|
|
40 to 240/250 °C |
ea. |
Select
Deselect
|
Catalog # 11052
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.00 µm
- ID
- 0.53 mm
- Length
- 15 m
- Temp Limits
- 40 to 240/250 °C
- Units
- ea.
- Similar To
-
Agilent 125-3212
Agilent 19095F-120
Grace 13873
Grace 5121962
Grace 8635191
Phenomenex 7EK-G009-22
|
11054 |
Stabilwax-DA |
1.00 µm |
0.32 mm |
30 m |
|
|
40 to 240/250 °C |
ea. |
Select
Deselect
|
Catalog # 11054
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.00 µm
- ID
- 0.32 mm
- Length
- 30 m
- Temp Limits
- 40 to 240/250 °C
- Units
- ea.
- Similar To
-
Agilent 123-3234
Scion/Bruker/Varian CP7767
|
11055 |
Stabilwax-DA |
1.00 µm |
0.53 mm |
30 m |
|
|
40 to 240/250 °C |
ea. |
Select
Deselect
|
Catalog # 11055
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.00 µm
- ID
- 0.53 mm
- Length
- 30 m
- Temp Limits
- 40 to 240/250 °C
- Units
- ea.
- Similar To
-
Agilent 125-3232
Agilent 19095F-123
Grace 14543
Grace 5121965
Grace 5122067
Grace 8635284
Phenomenex 7HK-G009-22
Scion/Bruker/Varian CP7486
Scion/Bruker/Varian CP7614
Grace 13877
|
11057 |
Stabilwax-DA |
1.00 µm |
0.32 mm |
60 m |
|
|
40 to 240/250 °C |
ea. |
Select
Deselect
|
Catalog # 11057
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.00 µm
- ID
- 0.32 mm
- Length
- 60 m
- Temp Limits
- 40 to 240/250 °C
- Units
- ea.
- Similar To
-
Agilent 123-3264
Grace 13276
Grace 8635358
Scion/Bruker/Varian CP7777
|
11058 |
Stabilwax-DA |
1.00 µm |
0.53 mm |
60 m |
|
|
40 to 240/250 °C |
ea. |
Select
Deselect
|
Catalog # 11058
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.00 µm
- ID
- 0.53 mm
- Length
- 60 m
- Temp Limits
- 40 to 240/250 °C
- Units
- ea.
- Similar To
-
Agilent 125-3262
Grace 13879
Grace 5121967
Grace 8635402
Scion/Bruker/Varian CP7624
|
11062 |
Stabilwax-DA |
1.50 µm |
0.53 mm |
15 m |
|
|
40 to 230/240 °C |
ea. |
Select
Deselect
|
Catalog # 11062
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.50 µm
- ID
- 0.53 mm
- Length
- 15 m
- Temp Limits
- 40 to 230/240 °C
- Units
- ea.
|
11065 |
Stabilwax-DA |
1.50 µm |
0.53 mm |
30 m |
|
|
40 to 230/240 °C |
ea. |
Select
Deselect
|
Catalog # 11065
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.50 µm
- ID
- 0.53 mm
- Length
- 30 m
- Temp Limits
- 40 to 230/240 °C
- Units
- ea.
- Similar To
-
Agilent 125-3233
Scion/Bruker/Varian CP7654
|
11068 |
Stabilwax-DA |
1.50 µm |
0.53 mm |
60 m |
|
|
40 to 230/240 °C |
ea. |
Select
Deselect
|
Catalog # 11068
- Product Name
- Stabilwax-DA
- df (Film Thickness)
- 1.50 µm
- ID
- 0.53 mm
- Length
- 60 m
- Temp Limits
- 40 to 230/240 °C
- Units
- ea.
|