Rxi-1301Sil MS Columns (fused silica)

midpolarity Crossbond phase
  • Highest thermal stability in the industry ensures dependable, accurate MS results and increased uptime.
  • Stabilized cyano phase selectivity improves the performance of existing methods. Ideal for solvents, glycols, and other polar compounds.
  • Rigorous QC testing ensures inertness and accurate, reliable data for multiple compound classes.
  • Maximum temperature: 320 °C.
Click here for more information on our Rxi columns.
Documentation and Instructions Sheets

Rxi-1301Sil MS Columns (fused silica)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
16094 30 m ea. 0.25 mm Rxi-1301Sil MS 0.25 µm -60 to 320 °C Select Deselect

Catalog # 16094

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320 °C  
16095 30 m ea. 0.25 mm Rxi-1301Sil MS 1.00 µm -60 to 320 °C Select Deselect

Catalog # 16095

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320 °C  
16096 60 m ea. 0.25 mm Rxi-1301Sil MS 0.25 µm -60 to 320 °C Select Deselect

Catalog # 16096

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320 °C  
16097 60 m ea. 0.25 mm Rxi-1301Sil MS 1.00 µm -60 to 320 °C Select Deselect

Catalog # 16097

Length
60 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320 °C  
16098 30 m ea. 0.32 mm Rxi-1301Sil MS 0.25 µm -60 to 320 °C Select Deselect

Catalog # 16098

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
0.25 µm  
Temp Limits
-60 to 320 °C  
16099 30 m ea. 0.32 mm Rxi-1301Sil MS 1.00 µm -60 to 320 °C Select Deselect

Catalog # 16099

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320 °C  
16100 60 m ea. 0.32 mm Rxi-1301Sil MS 1.00 µm -60 to 320 °C Select Deselect

Catalog # 16100

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320 °C  
16101 15 m ea. 0.53 mm Rxi-1301Sil MS 1.00 µm -60 to 320 °C Select Deselect

Catalog # 16101

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320 °C  
16102 30 m ea. 0.53 mm Rxi-1301Sil MS 1.00 µm -60 to 320 °C Select Deselect

Catalog # 16102

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.00 µm  
Temp Limits
-60 to 320 °C  
16104 30 m ea. 0.32 mm Rxi-1301Sil MS 1.50 µm -60 to 320 °C Select Deselect

Catalog # 16104

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 320 °C  
16105 60 m ea. 0.32 mm Rxi-1301Sil MS 1.50 µm -60 to 320 °C Select Deselect

Catalog # 16105

Length
60 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
1.50 µm  
Temp Limits
-60 to 320 °C  
16106 30 m ea. 0.53 mm Rxi-1301Sil MS 3.00 µm -60 to 280/300 °C Select Deselect

Catalog # 16106

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 280/300 °C  
16107 60 m ea. 0.53 mm Rxi-1301Sil MS 3.00 µm -60 to 280/300 °C Select Deselect

Catalog # 16107

Length
60 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rxi-1301Sil MS  
df (Film Thickness)
3.00 µm  
Temp Limits
-60 to 280/300 °C  

Cyano-based 1301 columns are general use GC columns that are well suited for the analysis of solvents across a range of volatilities. The cyano stationary phase provides more retention of polar compounds than a 5-type column; however, cyano-based stationary phases are prone to high bleed and poor robustness, limiting their utility. The new Rxi-1301Sil MS column from Restek is a silarylene-based cyano stationary phase that not only provides the column selectivity needed for analyzing less volatile compounds, but also significantly lowers column bleed and improves robustness.

The low maximum operating temperature that is characteristic of non-silarylene cyano phases is a well known drawback to using traditional 1301 columns for volatiles analysis. Due to their high bleed and low maximum temperatures, many 1301 columns do not perform well for MS analyses. In contrast, the robust Rxi-1301Sil MS column works extremely well for MS applications because it offers the highest maximum temperature and lowest bleed in the industry, leading to much more reliable and accurate MS results. Exceptionally high thermal stability produces robust column performance and allows for more aggressive thermal ramping to eliminate carryover of high molecular weight compounds between analyses (i.e., increased uptime).

In addition to providing both true 1301 selectivity and the lowest bleed/highest temperature limits in the industry, the Rxi-1301Sil MS column is designed to provide a high degree of inertness. Each Rxi-1301Sil MS column is tested with a QC mix that includes both acidic and basic probes to ensure inertness across multiple compound classes. Greater column inertness improves peak shape and response, ensuring more accurate quantitative results.

The new Rxi-1301Sil MS column is ideal for the analysis of multiple compound classes across a range of polarities and volatilities. With its cyano-based selectivity and high thermal stability, it is the best 1301-type column for robust MS analyses.

Similar Phases

Agilent: VF-1301ms