Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Innovative Integra-Guard Columns

Get the protection without the connection!

  • These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems!
  • The guard column section is marked separately from the analytical column, using high-temperature string.
  • A wide variety of our Integra-Guard capillary columns are available.
  • Analyzing residual solvents in pharmaceutical products? Use cat.# 16085-126 or 10279-126 below.
Documentation and Instructions Sheets

Innovative Integra-Guard Columns

Catalog # 10240-129

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10240-129 Rtx-5 0.50 µm 0.53 mm 30 m w/10 m Integra-Guard Column -60 to 310/330 °C ea. Select Deselect

Catalog # 10240-129

Product Name
Rtx-5  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10120-124 Rtx-1 0.25 µm 0.25 mm 15 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10120-124

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10123-124 Rtx-1 0.25 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10123-124

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10126-127 Rtx-1 0.25 µm 0.25 mm 60 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10126-127

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10127-125 Rtx-1 0.25 µm 0.32 mm 60 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10127-125

Product Name
Rtx-1  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10141-127 Rtx-1 0.50 µm 0.25 mm 60 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10141-127

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
60 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10142-125 Rtx-1 0.50 µm 0.32 mm 60 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10142-125

Product Name
Rtx-1  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
60 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10155-126 Rtx-1 1.00 µm 0.53 mm 30 m w/5 m Integra-Guard Column -60 to 310/330 °C ea. Select Deselect

Catalog # 10155-126

Product Name
Rtx-1  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 310/330 °C  
Units
ea.  
10179-126 Rtx-1 5.00 µm 0.53 mm 30 m w/5 m Integra-Guard Column -60 to 270/290 °C ea. Select Deselect

Catalog # 10179-126

Product Name
Rtx-1  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
10220-124 Rtx-5 0.25 µm 0.25 mm 15 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10220-124

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10223-124 Rtx-5 0.25 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10223-124

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10223-127 Rtx-5 0.25 µm 0.25 mm 30 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10223-127

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10224-125 Rtx-5 0.25 µm 0.32 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10224-125

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10227-125 Rtx-5 0.25 µm 0.32 mm 60 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10227-125

Product Name
Rtx-5  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10253-124 Rtx-5 1.00 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 320/340 °C ea. Select Deselect

Catalog # 10253-124

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 320/340 °C  
Units
ea.  
10254-125 Rtx-5 1.00 µm 0.32 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 10254-125

Product Name
Rtx-5  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
10279-126 Rtx-5/Rtx-G27 5.00 µm 0.53 mm 30 m w/5 m Integra-Guard Column -60 to 270/290 °C ea. Select Deselect

Catalog # 10279-126

Product Name
Rtx-5/Rtx-G27  
df (Film Thickness)
5.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 270/290 °C  
Units
ea.  
Note
Application-specific column for residual solvents in pharmaceutical products.  
10623-124 Stabilwax 0.25 µm 0.25 mm 30 m w/5 m Integra-Guard Column 40 to 250 °C ea. Select Deselect

Catalog # 10623-124

Product Name
Stabilwax  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
40 to 250 °C  
Units
ea.  
10654-125 Stabilwax 1.00 µm 0.32 mm 30 m w/5 m Integra-Guard Column 40 to 240/250 °C ea. Select Deselect

Catalog # 10654-125

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
40 to 240/250 °C  
Units
ea.  
10655-126 Stabilwax 1.00 µm 0.53 mm 30 m w/5 m Integra-Guard Column 40 to 240/250 °C ea. Select Deselect

Catalog # 10655-126

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
40 to 240/250 °C  
Units
ea.  
10655-129 Stabilwax 1.00 µm 0.53 mm 30 m w/10 m Integra-Guard Column 40 to 240/260 °C ea. Select Deselect

Catalog # 10655-129

Product Name
Stabilwax  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
40 to 240/260 °C  
Units
ea.  
10968-124 Rtx-624 1.40 µm 0.25 mm 30 m w/5 m Integra-Guard Column -20 to 240 °C ea. Select Deselect

Catalog # 10968-124

Product Name
Rtx-624  
df (Film Thickness)
1.40 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 240 °C  
Units
ea.  
10968-127 Rtx-624 1.40 µm 0.25 mm 30 m w/10 m Integra-Guard Column -20 to 240 °C ea. Select Deselect

Catalog # 10968-127

Product Name
Rtx-624  
df (Film Thickness)
1.40 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-20 to 240 °C  
Units
ea.  
10970-125 Rtx-624 1.80 µm 0.32 mm 30 m w/5 m Integra-Guard Column -20 to 240 °C ea. Select Deselect

Catalog # 10970-125

Product Name
Rtx-624  
df (Film Thickness)
1.80 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 240 °C  
Units
ea.  
10971-126 Rtx-624 3.00 µm 0.53 mm 30 m w/5 m Integra-Guard Column -20 to 240 °C ea. Select Deselect

Catalog # 10971-126

Product Name
Rtx-624  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 240 °C  
Units
ea.  
12023-124 Rtx-1701 0.25 µm 0.25 mm 30 m w/5 m Integra-Guard Column -20 to 280 °C ea. Select Deselect

Catalog # 12023-124

Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 280 °C  
Units
ea.  
12024-125 Rtx-1701 0.25 µm 0.32 mm 30 m w/5 m Integra-Guard Column -20 to 280 °C ea. Select Deselect

Catalog # 12024-125

Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 280 °C  
Units
ea.  
12024-128 Rtx-1701 0.25 µm 0.32 mm 30 m w/10 m Integra-Guard Column -20 to 280 °C ea. Select Deselect

Catalog # 12024-128

Product Name
Rtx-1701  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-20 to 280 °C  
Units
ea.  
12038-124 Rtx-1701 0.50 µm 0.25 mm 30 m w/5 m Integra-Guard Column -20 to 270/280 °C ea. Select Deselect

Catalog # 12038-124

Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 270/280 °C  
Units
ea.  
12039-125 Rtx-1701 0.50 µm 0.32 mm 30 m w/5 m Integra-Guard Column -20 to 270/280 °C ea. Select Deselect

Catalog # 12039-125

Product Name
Rtx-1701  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 270/280 °C  
Units
ea.  
12053-124 Rtx-1701 1.00 µm 0.25 mm 30 m w/5 m Integra-Guard Column -20 to 260/280 °C ea. Select Deselect

Catalog # 12053-124

Product Name
Rtx-1701  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 260/280 °C  
Units
ea.  
12608-124 Rtx-5MS 0.10 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12608-124

Product Name
Rtx-5MS  
df (Film Thickness)
0.10 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12620-124 Rtx-5MS 0.25 µm 0.25 mm 15 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12620-124

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12620-124600 Rtx-5MS 0.25 µm 0.25 mm 15 m w/5 m Integra-Guard Column -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 12620-124600

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
12623-124 Rtx-5MS 0.25 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12623-124

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12623-127 Rtx-5MS 0.25 µm 0.25 mm 30 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12623-127

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12624-125 Rtx-5MS 0.25 µm 0.32 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12624-125

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12626-124 Rtx-5MS 0.25 µm 0.25 mm 60 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12626-124

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12626-127 Rtx-5MS 0.25 µm 0.25 mm 60 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12626-127

Product Name
Rtx-5MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12635-127 Rtx-5MS 0.50 µm 0.25 mm 15 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12635-127

Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12638-124 Rtx-5MS 0.50 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12638-124

Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12638-127 Rtx-5MS 0.50 µm 0.25 mm 30 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 12638-127

Product Name
Rtx-5MS  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
12654-125 Rtx-5MS 1.00 µm 0.32 mm 30 m w/5 m Integra-Guard Column -60 to 325/350 °C ea. Select Deselect

Catalog # 12654-125

Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 325/350 °C  
Units
ea.  
12654-128 Rtx-5MS 1.00 µm 0.32 mm 30 m w/10 m Integra-Guard Column -60 to 325/350 °C ea. Select Deselect

Catalog # 12654-128

Product Name
Rtx-5MS  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 325/350 °C  
Units
ea.  
13620-127 Rxi-5Sil MS 0.25 µm 0.25 mm 15 m w/10 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 13620-127

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13623-124 Rxi-5Sil MS 0.25 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13623-124

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
Similar To
Agilent 122-5631G5
Phenomenex 7HG-G010-11-GGA
13623-127 Rxi-5Sil MS 0.25 µm 0.25 mm 30 m w/10 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13623-127

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
Similar To
Agilent 122-5532G
Phenomenex 7HG-G010-11-GGC
13626-124 Rxi-5Sil MS 0.25 µm 0.25 mm 60 m w/5 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13626-124

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
13626-127 Rxi-5Sil MS 0.25 µm 0.25 mm 60 m w/10 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13626-127

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
13635-124 Rxi-5Sil MS 0.50 µm 0.25 mm 15 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 13635-124

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13638-124 Rxi-5Sil MS 0.50 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13638-124

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
13638-127 Rxi-5Sil MS 0.50 µm 0.25 mm 30 m w/10 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13638-127

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/10 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
Similar To
Agilent 122-5536G
13639-125 Rxi-5Sil MS 0.50 µm 0.32 mm 30 m w/5 m Integra-Guard Column -60 to 330/350 °C ea. Select Deselect

Catalog # 13639-125

Product Name
Rxi-5Sil MS  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13653-124 Rxi-5Sil MS 1.00 µm 0.25 mm 30 m w/5 m Integra-Guard Column -60 to 320/350 °C ea. Select Deselect

Catalog # 13653-124

Product Name
Rxi-5Sil MS  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 320/350 °C  
Units
ea.  
13654-125 Rxi-5Sil MS 1.00 µm 0.32 mm 30 m w/5 m Integra-Guard Column -60 to 325/350 °C ea. Select Deselect

Catalog # 13654-125

Product Name
Rxi-5Sil MS  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-60 to 325/350 °C  
Units
ea.  
16085-126 Rtx-1301/Rtx-G43 3.00 µm 0.53 mm 30 m w/5 m Integra-Guard Column -20 to 240 °C ea. Select Deselect

Catalog # 16085-126

Product Name
Rtx-1301/Rtx-G43  
df (Film Thickness)
3.00 µm  
ID
0.53 mm  
Length
30 m  
Modification
w/5 m Integra-Guard Column  
Temp Limits
-20 to 240 °C  
Units
ea.  
Note
Application-specific column for residual solvents in pharmaceutical products. Meets all requirements of USP <467>.  

  • No leaks for a more robust method.
  • No column connections for easier, faster maintenance.
  • No peak distortions due to connector dead volume and thermal capacity.

For analysts who find it inconvenient to make a leak-free connection between the guard column and the analytical column, we offer Integra-Guard columns. These innovative columns incorporate both a guard column and an analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems! The guard column section is marked separately from the analytical column using high-temperature string.

A wide variety of our Integra-Guard capillary columns are listed here. The Integra-Guard column is so economical that we challenge you to compare our price against that of a conventional connection, even if you assemble it yourself. If you are currently using a guard column, or are considering using one, call today and ask about Integra-Guard columns.

If you don’t see what you need here, contact Customer Service.

Similar Phases

Alltech/MEGA S.r.l.: DuraGuard

Agilent: EZ-Guard

Phenomenex: Guardian