Rxi-1ms Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane
  • General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO).
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G1, G2, and G38 phases.
Ordering Notes
Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

SAVE MONEY! Get six columns for the price of five. Contact Customer Service or your local Restek representative for details!
Documentation and Instructions Sheets

Rxi-1ms Columns (fused silica)

Catalog # 13323

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
13323 Rxi-1ms 0.25 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13323

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-0132
Agilent 19091S-933
Phenomenex 7HG-G011-11
13301 Rxi-1ms 0.10 µm 0.10 mm 10 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13301

Product Name
Rxi-1ms  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
10 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 127-0112
Phenomenex 7CB-G011-02
13302 Rxi-1ms 0.18 µm 0.18 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13302

Product Name
Rxi-1ms  
df (Film Thickness)
0.18 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 121-0122
Agilent 19091S-677
Phenomenex 7FD-G011-08
13311 Rxi-1ms 0.36 µm 0.18 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13311

Product Name
Rxi-1ms  
df (Film Thickness)
0.36 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13320 Rxi-1ms 0.25 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13320

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-0112
Agilent 19091S-931
Phenomenex 7EG-G011-11
13320-600 Rxi-1ms 0.25 µm 0.25 mm 15 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 13320-600

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
13321 Rxi-1ms 0.25 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13321

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-0112
Agilent 19091S-911
Phenomenex 7EM-G011-11
13324 Rxi-1ms 0.25 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13324

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-0132
Agilent 19091S-913
Phenomenex 7HM-G011-11
13326 Rxi-1ms 0.25 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13326

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 122-0162
Agilent 19091S-936
Phenomenex 7KG-G011-11
13327 Rxi-1ms 0.25 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13327

Product Name
Rxi-1ms  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 123-0162
Agilent 19091S-916
13335 Rxi-1ms 0.50 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13335

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13336 Rxi-1ms 0.50 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13336

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13337 Rxi-1ms 0.50 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13337

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13338 Rxi-1ms 0.50 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13338

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-633
Phenomenex 7HG-G011-17
13339 Rxi-1ms 0.50 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13339

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13340 Rxi-1ms 0.50 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13340

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13341 Rxi-1ms 0.50 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13341

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13342 Rxi-1ms 0.50 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13342

Product Name
Rxi-1ms  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13350 Rxi-1ms 1.00 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13350

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13352 Rxi-1ms 1.00 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13352

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13353 Rxi-1ms 1.00 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13353

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-733
Phenomenex 7HG-G011-22
13354 Rxi-1ms 1.00 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13354

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-713
Phenomenex 7HM-G011-22
13355 Rxi-1ms 1.00 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13355

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13356 Rxi-1ms 1.00 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13356

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Phenomenex 7KG-G011-22
13357 Rxi-1ms 1.00 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13357

Product Name
Rxi-1ms  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Phenomenex 7KM-G011-22
13367 Rxi-1ms 1.50 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13367

Product Name
Rxi-1ms  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13370 Rxi-1ms 1.50 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13370

Product Name
Rxi-1ms  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13373 Rxi-1ms 1.50 µm 0.53 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13373

Product Name
Rxi-1ms  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13396 Rxi-1ms 4.00 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13396

Product Name
Rxi-1ms  
df (Film Thickness)
4.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13397 Rxi-1ms 0.33 µm 0.20 mm 12 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13397

Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
12 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 128-0112
Phenomenex 7DE-G011-14
13397-600 Rxi-1ms 0.33 µm 0.20 mm 12 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 13397-600

Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
12 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
13398 Rxi-1ms 0.33 µm 0.20 mm 25 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13398

Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
25 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 128-0122
Agilent 19091S-602
Phenomenex 7GE-G011-14
13399 Rxi-1ms 0.33 µm 0.20 mm 50 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13399

Product Name
Rxi-1ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
50 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
15106 Rxi-1ms 0.10 µm 0.10 mm 1.1 m (±3 cm) -60 to 330/350 °C ea. Select Deselect

Catalog # 15106

Product Name
Rxi-1ms  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
1.1 m (±3 cm)  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
43800 Rxi-1ms 0.15 µm 0.15 mm 10 m -60 to 330/350 °C ea. Select Deselect

Catalog # 43800

Product Name
Rxi-1ms  
df (Film Thickness)
0.15 µm  
ID
0.15 mm  
Length
10 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
43801 Rxi-1ms 0.15 µm 0.15 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 43801

Product Name
Rxi-1ms  
df (Film Thickness)
0.15 µm  
ID
0.15 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
43802 Rxi-1ms 2.0 µm 0.15 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 43802

Product Name
Rxi-1ms  
df (Film Thickness)
2.0 µm  
ID
0.15 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  

Similar Phases

Agilent: DB-1ms, DB-1msUI, HP-1ms, HP-1msUI, VF-1ms

Phenomenex: ZB-1ms

Quadrex: 007-1MS

Supelco/Millipore Sigma: SLB-1ms