Rxi-5ms Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane
  • Ideal for pesticides in food.
  • General-purpose columns that can be used for phenols, residual solvents, drugs of abuse, pesticides, semivolatiles, PCB congeners (e.g., Aroclor mixes), and solvent impurities.
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G27 and G36 phases.

View related literature on the analysis of cholesterol and garlic volatiles.

Ordering Notes
Custom lengths and film thicknesses available. Contact Technical Service or your local Restek representative.

SAVE MONEY! Get six columns for the price of five. Contact Customer Service or your local Restek representative for details!
Documentation and Instructions Sheets

Rxi-5ms Columns (fused silica)

Catalog # 13424

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
13424 Rxi-5ms 0.25 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13424

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-413UI
Phenomenex 7HM-G032-11
13401 Rxi-5ms 0.10 µm 0.10 mm 10 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13401

Product Name
Rxi-5ms  
df (Film Thickness)
0.10 µm  
ID
0.10 mm  
Length
10 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13402 Rxi-5ms 0.18 µm 0.18 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13402

Product Name
Rxi-5ms  
df (Film Thickness)
0.18 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13409 Rxi-5ms 0.30 µm 0.18 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13409

Product Name
Rxi-5ms  
df (Film Thickness)
0.30 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13411 Rxi-5ms 0.36 µm 0.18 mm 20 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13411

Product Name
Rxi-5ms  
df (Film Thickness)
0.36 µm  
ID
0.18 mm  
Length
20 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13420 Rxi-5ms 0.25 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13420

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-431UI
Phenomenex 7EG-G032-11
13421 Rxi-5ms 0.25 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13421

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13422 Rxi-5ms 0.25 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13422

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13423 Rxi-5ms 0.25 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13423

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-433UI
Phenomenex 7HG-G032-11
13423-600 Rxi-5ms 0.25 µm 0.25 mm 30 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 13423-600

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
13425 Rxi-5ms 0.25 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13425

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13426 Rxi-5ms 0.25 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13426

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-436UI
13427 Rxi-5ms 0.25 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13427

Product Name
Rxi-5ms  
df (Film Thickness)
0.25 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13435 Rxi-5ms 0.50 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13435

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13436 Rxi-5ms 0.50 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13436

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13437 Rxi-5ms 0.50 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13437

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13438 Rxi-5ms 0.50 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13438

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-133UI
Phenomenex 7HG-G032-17
13439 Rxi-5ms 0.50 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13439

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Phenomenex 7HM-G032-17
13440 Rxi-5ms 0.50 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13440

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13441 Rxi-5ms 0.50 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13441

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13442 Rxi-5ms 0.50 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13442

Product Name
Rxi-5ms  
df (Film Thickness)
0.50 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13450 Rxi-5ms 1.00 µm 0.25 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13450

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13451 Rxi-5ms 1.00 µm 0.32 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13451

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13452 Rxi-5ms 1.00 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13452

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13453 Rxi-5ms 1.00 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13453

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-233UI
Phenomenex 7HG-G032-22
13454 Rxi-5ms 1.00 µm 0.32 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13454

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
Similar To
Agilent 19091S-213UI
Phenomenex 7HM-G032-22
13455 Rxi-5ms 1.00 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13455

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13455-600 Rxi-5ms 1.00 µm 0.53 mm 30 m -60 to 330/350 °C 6-pk. Select Deselect

Catalog # 13455-600

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
6-pk.  
13456 Rxi-5ms 1.00 µm 0.25 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13456

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.25 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13457 Rxi-5ms 1.00 µm 0.32 mm 60 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13457

Product Name
Rxi-5ms  
df (Film Thickness)
1.00 µm  
ID
0.32 mm  
Length
60 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13467 Rxi-5ms 1.50 µm 0.53 mm 15 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13467

Product Name
Rxi-5ms  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
15 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13470 Rxi-5ms 1.50 µm 0.53 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13470

Product Name
Rxi-5ms  
df (Film Thickness)
1.50 µm  
ID
0.53 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13481 Rxi-5ms 0.40 µm 0.25 mm 30 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13481

Product Name
Rxi-5ms  
df (Film Thickness)
0.40 µm  
ID
0.25 mm  
Length
30 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13497 Rxi-5ms 0.33 µm 0.20 mm 12 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13497

Product Name
Rxi-5ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
12 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13498 Rxi-5ms 0.33 µm 0.20 mm 25 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13498

Product Name
Rxi-5ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
25 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  
13499 Rxi-5ms 0.33 µm 0.20 mm 50 m -60 to 330/350 °C ea. Select Deselect

Catalog # 13499

Product Name
Rxi-5ms  
df (Film Thickness)
0.33 µm  
ID
0.20 mm  
Length
50 m  
Temp Limits
-60 to 330/350 °C  
Units
ea.  

Similar Phases

Agilent: HP-5msUI

Phenomenex: ZB-5plus