Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Rtx-DHA Columns (fused silica)

Crossbond 100% dimethyl polysiloxane—optimized for hydrocarbon analysis
  • Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column.
  • Excellent responses and peak symmetry for polar oxygenates.
  • Can be used for ASTM D5134, D6729, D6733, D5501, D5441, D7266, and D7871. For more information, see our ASTM Method Product Guide.
  • Temperature range: -60 °C to 340 °C.

Don't forget: The ASTM D6730 method also requires a tuning column—Rtx-5 DHA Tuning Column

Documentation and Instructions Sheets

Rtx-DHA Columns (fused silica)

Catalog # 10149

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
10149 Rtx-DHA-150 1.0 µm 0.25 mm 150 m -60 to 280/340 °C ea. Select Deselect

Catalog # 10149

Product Name
Rtx-DHA-150  
df (Film Thickness)
1.0 µm  
ID
0.25 mm  
Length
150 m  
Temp Limits
-60 to 280/340 °C  
Units
ea.  
10147 Rtx-DHA-50 0.50 µm 0.20 mm 50 m -60 to 300/340 °C ea. Select Deselect

Catalog # 10147

Product Name
Rtx-DHA-50  
df (Film Thickness)
0.50 µm  
ID
0.20 mm  
Length
50 m  
Temp Limits
-60 to 300/340 °C  
Units
ea.  
10148 Rtx-DHA-100 0.50 µm 0.25 mm 100 m -60 to 300/340 °C ea. Select Deselect

Catalog # 10148

Product Name
Rtx-DHA-100  
df (Film Thickness)
0.50 µm  
ID
0.25 mm  
Length
100 m  
Temp Limits
-60 to 300/340 °C  
Units
ea.  

Gasolines are complex mixtures of hundreds of compounds. Information about concentrations of the individual components is important for evaluating raw materials and for controlling refinery processes. ASTM D6730-01 outlines a high-resolution GC method for detailed hydrocarbon analysis (DHA) of gasolines. Rtx-DHA columns are ideal for DHA methods and easily meet or exceed both ASTM D6730-01 and Canadian General Standards Board CAN/CGSB 3.0 No. 14.3-99 requirements. Every Rtx-DHA column is tested for retention, efficiency, stationary phase selectivity, and bleed—guaranteeing reproducible column-to-column performance.
Similar Phases

Trajan Scientific: BP1PONA

Agilent: CP-Sil PONA C8, DB-Petro, HP-PONA

Supelco/Millipore Sigma: Petrocol DH