Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

D3606 Application Column Set (packed, 2 column set)

  • Accurate quantification of toluene and benzene—including benzene in gasoline containing ethanol or butanol blends.
  • Complete resolution of benzene from ethanol—no compromising coelutions.
  • Enhanced formulation with improved support material and polymers—more robust and reproducible.
  • Column sets are individually tested for D3606 method applicability.
  • QC test chromatogram includes approximate backflush times.
  • Listed in the ASTM Method D3606—attain better separation of benzene and ethanol while following ASTM method requirements.
  • Exclusively available from Restek. Includes Column 1: backflush column, 6' (1.8 m), 1/8" OD, 2.0 mm ID; Column 2: proprietary packing, 15.5' (4.7 m), 1/8" OD, 2.0 mm ID.

Note: Our current D3606 column set (cat.# 83606A) requires a longer backflush time. Please refer to the QC certificate for the approximate backflush time.

Ordering Notes

See Additional Product Details below for column configuration key.

Custom packed and micropacked columns also available by request.

Documentation and Instructions Sheets

D3606 Application Column Set (packed, 2 column set)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
83606A-800 D3606 Application Column (2 column set) General up to 140 °C 2 column set Select Deselect

Catalog # 83606A-800

Product Name
D3606 Application Column (2 column set)  
Column Configuration
General  
Temp Limits
up to 140 °C  
Units
2 column set  
Similar To
Restek 83606-800
83606A-810 D3606 Application Column (2 column set) Agilent up to 140 °C 2 column set Select Deselect

Catalog # 83606A-810

Product Name
D3606 Application Column (2 column set)  
Column Configuration
Agilent  
Temp Limits
up to 140 °C  
Units
2 column set  
Similar To
Restek 83606-810
83606A-811 D3606 Application Column (2 column set) Agilent 6850 up to 140 °C 2 column set Select Deselect

Catalog # 83606A-811

Product Name
D3606 Application Column (2 column set)  
Column Configuration
Agilent 6850  
Temp Limits
up to 140 °C  
Units
2 column set  
83606A-821 D3606 Application Column (2 column set) Bruker 430, 450, Varian 3800 up to 140 °C 2 column set Select Deselect

Catalog # 83606A-821

Product Name
D3606 Application Column (2 column set)  
Column Configuration
Bruker 430, 450, Varian 3800  
Temp Limits
up to 140 °C  
Units
2 column set  
83606A-840 D3606 Application Column (2 column set) PE Auto Sys up to 140 °C 2 column set Select Deselect

Catalog # 83606A-840

Product Name
D3606 Application Column (2 column set)  
Column Configuration
PE Auto Sys  
Temp Limits
up to 140 °C  
Units
2 column set  
Similar To
Restek 83606-840
83606A-850 D3606 Application Column (2 column set) Shimadzu 14A up to 140 °C 2 column set Select Deselect

Catalog # 83606A-850

Product Name
D3606 Application Column (2 column set)  
Column Configuration
Shimadzu 14A  
Temp Limits
up to 140 °C  
Units
2 column set  
Similar To
Restek 83606-850

Conforms to the specifications established in the current ASTM method D3606 for the quantitation of benzene and toluene in spark ignition fuel containing ethanol.

The inlet is identified on both column 1 and column 2. Note: The inlet of column 2 is identified for proper orientation for connection to the valve.

Column Configuration Key:
-800 General—General Configuration
-810 Agilent—(HP) 5880, 5890, 5987, 6890, 7980
-811 Agilent 6850
-821 Bruker 430, 450, Varian 3800
-840 PE Auto Sys—PE Auto System 8300/8400/8700, Clarus 500
-850 Shimadzu 14A—Shimadzu 14A, 2014

Other column configurations available.