Rt-Q-BOND Columns (fused silica PLOT)

100% divinylbenzene
  • Nonpolar PLOT column incorporating 100% divinylbenzene.
  • Excellent for analysis of C1 to C3 hydrocarbons as well as isomers and alkanes up to C10.
  • High retention for CO2 simplifies gas analysis; CO2 and methane separated from O2/N2/CO. (Note: O2/N2/CO not separated at ambient temperature.)
  • Use for analysis of oxygenated compounds and solvents.
  • Maximum temperature of 300 °C.
A GC column phase cross-reference is also available.
Documentation and Instructions Sheets

Rt-Q-BOND Columns (fused silica PLOT)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
19741 15 m ea. 0.53 mm 20 µm -60 to 280/300 °C Select Deselect

Catalog # 19741

Length
15 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rt-Q-BOND  
df (Film Thickness)
20 µm  
Temp Limits
-60 to 280/300 °C  
19742 30 m ea. 0.53 mm 20 µm -60 to 280/300 °C Select Deselect

Catalog # 19742

Length
30 m  
Units
ea.  
ID
0.53 mm  
Product Name
Rt-Q-BOND  
df (Film Thickness)
20 µm  
Temp Limits
-60 to 280/300 °C  
19743 15 m ea. 0.32 mm 10 µm -60 to 280/300 °C Select Deselect

Catalog # 19743

Length
15 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rt-Q-BOND  
df (Film Thickness)
10 µm  
Temp Limits
-60 to 280/300 °C  
19744 30 m ea. 0.32 mm 10 µm -60 to 280/300 °C Select Deselect

Catalog # 19744

Length
30 m  
Units
ea.  
ID
0.32 mm  
Product Name
Rt-Q-BOND  
df (Film Thickness)
10 µm  
Temp Limits
-60 to 280/300 °C  
19764 15 m ea. 0.25 mm 8 µm -60 to 280/300 °C Select Deselect

Catalog # 19764

Length
15 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rt-Q-BOND  
df (Film Thickness)
8 µm  
Temp Limits
-60 to 280/300 °C  
19765 30 m ea. 0.25 mm 8 µm -60 to 280/300 °C Select Deselect

Catalog # 19765

Length
30 m  
Units
ea.  
ID
0.25 mm  
Product Name
Rt-Q-BOND  
df (Film Thickness)
8 µm  
Temp Limits
-60 to 280/300 °C  

Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic peak. The Q-BOND is our most nonpolar and widely used porous polymer column; functional groups can be added to increase polarity (i.e., QS-, S-, and U-BOND). The process used to manufacture porous polymer PLOT columns causes the particles to adhere strongly to the walls of the tubing, so there is virtually no particle generation. You get reproducible performance from column to column, including selectivity and flow.

We do not recommend recoiling PLOT columns as this may cause particles to dislodge from the side of the tubing.
Similar Phases

Supelco/Millipore Sigma: Supel-Q-PLOT

Alltech/MEGA S.r.l.: AT-Q

Agilent: CP-PoraBOND Q, CP-PoraPLOT Q, HP PLOT Q