Raptor ARC-18 LC Columns (USP L1)

  • Ideal for high-throughput LC-MS/MS applications with minimal sample preparation.
  • Well-balanced retention profile for better detection and integration of large, multiclass analyte lists.
  • Sterically protected to endure low-pH mobile phases without sacrificing retention or peak quality.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.
Ordering Notes

Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.

Documentation and Instructions Sheets

Raptor ARC-18 LC Columns (USP L1)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9314212 2.1 mm 100 mm 1.8 µm ea. Select Deselect

Catalog # 9314212

ID
2.1 mm  
Length
100 mm  
Particle Size
1.8 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
931421E 3.0 mm 100 mm 1.8 µm ea. Select Deselect

Catalog # 931421E

ID
3.0 mm  
Length
100 mm  
Particle Size
1.8 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314232 2.1 mm 30 mm 1.8 µm ea. Select Deselect

Catalog # 9314232

ID
2.1 mm  
Length
30 mm  
Particle Size
1.8 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314252 2.1 mm 50 mm 1.8 µm ea. Select Deselect

Catalog # 9314252

ID
2.1 mm  
Length
50 mm  
Particle Size
1.8 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
931425E 3.0 mm 50 mm 1.8 µm ea. Select Deselect

Catalog # 931425E

ID
3.0 mm  
Length
50 mm  
Particle Size
1.8 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314262 2.1 mm 150 mm 1.8 µm ea. Select Deselect

Catalog # 9314262

ID
2.1 mm  
Length
150 mm  
Particle Size
1.8 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314512 2.1 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9314512

ID
2.1 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314515 4.6 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9314515

ID
4.6 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
931451E 3.0 mm 100 mm 5 µm ea. Select Deselect

Catalog # 931451E

ID
3.0 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
931453E 3.0 mm 30 mm 5 µm ea. Select Deselect

Catalog # 931453E

ID
3.0 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314552 2.1 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9314552

ID
2.1 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314555 4.6 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9314555

ID
4.6 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
931455E 3.0 mm 50 mm 5 µm ea. Select Deselect

Catalog # 931455E

ID
3.0 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314562 2.1 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9314562

ID
2.1 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314565 4.6 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9314565

ID
4.6 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
931456E 3.0 mm 150 mm 5 µm ea. Select Deselect

Catalog # 931456E

ID
3.0 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314575 4.6 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9314575

ID
4.6 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A12 2.1 mm 100 mm 2.7 µm ea. Select Deselect

Catalog # 9314A12

ID
2.1 mm  
Length
100 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A15 4.6 mm 100 mm 2.7 µm ea. Select Deselect

Catalog # 9314A15

ID
4.6 mm  
Length
100 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A1E 3.0 mm 100 mm 2.7 µm ea. Select Deselect

Catalog # 9314A1E

ID
3.0 mm  
Length
100 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A32 2.1 mm 30 mm 2.7 µm ea. Select Deselect

Catalog # 9314A32

ID
2.1 mm  
Length
30 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A35 4.6 mm 30 mm 2.7 µm ea. Select Deselect

Catalog # 9314A35

ID
4.6 mm  
Length
30 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A3E 3.0 mm 30 mm 2.7 µm ea. Select Deselect

Catalog # 9314A3E

ID
3.0 mm  
Length
30 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A52 2.1 mm 50 mm 2.7 µm ea. Select Deselect

Catalog # 9314A52

ID
2.1 mm  
Length
50 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A55 4.6 mm 50 mm 2.7 µm ea. Select Deselect

Catalog # 9314A55

ID
4.6 mm  
Length
50 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A5E 3.0 mm 50 mm 2.7 µm ea. Select Deselect

Catalog # 9314A5E

ID
3.0 mm  
Length
50 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A62 2.1 mm 150 mm 2.7 µm ea. Select Deselect

Catalog # 9314A62

ID
2.1 mm  
Length
150 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A65 4.6 mm 150 mm 2.7 µm ea. Select Deselect

Catalog # 9314A65

ID
4.6 mm  
Length
150 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  
9314A6E 3.0 mm 150 mm 2.7 µm ea. Select Deselect

Catalog # 9314A6E

ID
3.0 mm  
Length
150 mm  
Particle Size
2.7 µm  
Units
ea.  
Pore Size
90 Å  
Product Name
Raptor ARC-18  

Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or "core-shell" particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and faster analysis times with existing HPLC and UHPLC instrumentation. Learn more about Raptor LC columns at www.restek.com/raptor

Designed and intended specifically for use on LC-MS/MS systems, the Raptor ARC-18 column offers a well-balanced retention profile without the drawbacks of using an ordinary C18 in the harsh, acidic mobile phases needed for mass spectrometry (MS). Even after extended use in these low-pH (≤ 2.0) conditions, the sterically protected ARC-18 offers consistent retention, peak shape, and response for charged bases, neutral acids, small polar compounds, and more. For the rapid analysis of large, multiclass assays by LC-MS/MS, the acid-resistant Raptor ARC-18 column truly is ahead of the curve.

Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: Sterically protected C18
Particle: 1.8 µm, 2.7 µm, or 5 µm superficially porous particle (SPP or “core-shell” particle) silica
Pore Size: 90 Å
Carbon Load: 7% (1.8 µm), 7% (2.7 μm), 5% (5 μm)
End-Cap: no
Surface Area: 125 m2/g (1.8 µm), 130 m2/g (2.7 µm), or 100 m2/g (5 µm)
Recommended Usage:
pH Range: 1.0–8.0
Maximum Temperature: 80 °C
Maximum Pressure: 1034 bar/15,000 psi* (1.8 μm), 600 bar/8700 psi (2.7 μm); 400 bar/5800 psi (5 μm)

* For maximum lifetime, recommended maximum pressure for 1.8 μm particles is 830 bar/12,000 psi.

Properties:
  • Well-balanced retention profile.
  • Sterically protected and acid resistant to resist harsh, low-pH mobile phases.
  • Ideal for use with sensitive detectors like mass spec.
Switch to an ARC-18 column when:
  • You are analyzing large, multiclass lists by LC-MS/MS.
  • Strongly acidic (pH 1–3) mobile phases are required.
Similar Phases

Thermo Fisher Scientific: Accucore XL C18

Supelco/Millipore Sigma: Ascentis Express Peptide ES-C18

Phenomenex: Kinetex XB-C18

Agilent: Poroshell 120 SB-C18