Ultra Carbamate Columns

Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: proprietary
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ordering Notes

Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.

Documentation and Instructions Sheets

Ultra Carbamate Columns

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9177312 2.1 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9177312

ID
2.1 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
9177315 4.6 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9177315

ID
4.6 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
917731E 3.0 mm 100 mm 3 µm ea. Select Deselect

Catalog # 917731E

ID
3.0 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
9177352 2.1 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9177352

ID
2.1 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
9177354 4.0 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9177354

ID
4.0 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
9177355 4.6 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9177355

ID
4.6 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
917735E 3.0 mm 50 mm 3 µm ea. Select Deselect

Catalog # 917735E

ID
3.0 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  
9177575 4.6 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9177575

ID
4.6 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
100 Å  
Product Name
Ultra Carbamate  

The Ultra line represents Restek’s broadest selection of stationary phases on a single silica support. Made of high-purity, type-B silica that minimizes activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications.
Restek chemists developed the Ultra Carbamate column specifically for carbamates analysis. The unique packing separates 10 target carbamates in just 5 minutes with an 8 minute total cycle time. The column is compatible with fluorescence or LC-MS detection.* An Ultra Carbamate column can process as many as eight samples per hour, versus less than two samples per hour on a general-purpose C18 column. In addition to increased sample throughput, this much faster analysis will significantly reduce solvent usage—and the costs of disposing of solvent waste. Refer to featured application EVSS2394A-UNV for more information.
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: proprietary
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
*For post-column derivatization/fluorescence detection applications using a 4.6 mm ID column, the total system dead volume, including the post-column reactor, must be less than 650 μL. For standard post-column reactor systems, we recommend a 250 mm x 4.6 mm, 5 μm column. Contact Restek Technical Service or your local Restek representative for more information.
Similar Phases

: Unique