Viva C18 Columns (USP L1)

Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: monomeric C18
Particle: 3 µm or 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 9%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Guard column requires Trident LC column protection system or Trident HPLC in-line guard cartridge holder.

Ordering Notes

Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.

Documentation and Instructions Sheets

Viva C18 Columns (USP L1)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9514311 1.0 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9514311

ID
1.0 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514312 2.1 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9514312

ID
2.1 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514315 4.6 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9514315

ID
4.6 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951431E 3.0 mm 100 mm 3 µm ea. Select Deselect

Catalog # 951431E

ID
3.0 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514331 1.0 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9514331

ID
1.0 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514332 2.1 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9514332

ID
2.1 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514335 4.6 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9514335

ID
4.6 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951433E 3.0 mm 30 mm 3 µm ea. Select Deselect

Catalog # 951433E

ID
3.0 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514351 1.0 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9514351

ID
1.0 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514352 2.1 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9514352

ID
2.1 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514355 4.6 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9514355

ID
4.6 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951435E 3.0 mm 50 mm 3 µm ea. Select Deselect

Catalog # 951435E

ID
3.0 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514361 1.0 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9514361

ID
1.0 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514362 2.1 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9514362

ID
2.1 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514365 4.6 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9514365

ID
4.6 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951436E 3.0 mm 150 mm 3 µm ea. Select Deselect

Catalog # 951436E

ID
3.0 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514511 1.0 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9514511

ID
1.0 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514512 2.1 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9514512

ID
2.1 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514515 4.6 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9514515

ID
4.6 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951451E 3.0 mm 100 mm 5 µm ea. Select Deselect

Catalog # 951451E

ID
3.0 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514521 1.0 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9514521

ID
1.0 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514522 2.1 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9514522

ID
2.1 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514525 4.6 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9514525

ID
4.6 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951452E 3.0 mm 200 mm 5 µm ea. Select Deselect

Catalog # 951452E

ID
3.0 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514531 1.0 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9514531

ID
1.0 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514532 2.1 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9514532

ID
2.1 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514535 4.6 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9514535

ID
4.6 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951453E 3.0 mm 30 mm 5 µm ea. Select Deselect

Catalog # 951453E

ID
3.0 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514551 1.0 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9514551

ID
1.0 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514552 2.1 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9514552

ID
2.1 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514555 4.6 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9514555

ID
4.6 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951455E 3.0 mm 50 mm 5 µm ea. Select Deselect

Catalog # 951455E

ID
3.0 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514561 1.0 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9514561

ID
1.0 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514562 2.1 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9514562

ID
2.1 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514565 4.6 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9514565

ID
4.6 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951456E 3.0 mm 150 mm 5 µm ea. Select Deselect

Catalog # 951456E

ID
3.0 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514571 1.0 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9514571

ID
1.0 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514572 2.1 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9514572

ID
2.1 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
9514575 4.6 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9514575

ID
4.6 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  
951457E 3.0 mm 250 mm 5 µm ea. Select Deselect

Catalog # 951457E

ID
3.0 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
300 Å  
Product Name
Viva C18  

  • Excellent for separating peptides or proteins.
  • Rugged, spherical particles with 300 Å pore size.
  • High proportion of pore/surface area available to large molecules.

Viva columns are based on a wide pore material we designed for optimal large-molecule separations. In developing Viva silica, we found that although many commercial wide-pore silicas meet the standard 300 Å mean pore size, most have very broad distributions about this mean, with a significant portion of their pore volume falling below 150 Å. This means a large portion of the surface area is unavailable to larger molecules. Viva columns have a narrow distribution around the mean pore size, permitting a larger portion of the silica surface to play a role in the separation.

The general-purpose Restek C18 is a conventional monomeric octadecylsilane column suitable for analyses of a wide range of compounds from acidic through slightly basic.
Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: monomeric C18
Particle: 3 µm or 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 9%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Similar Phases

Waters: Symmetry 300 C18

Synchrom: Synchropak C18

Agilent: Zorbax 300 OSB C18

Vydac/Hichrom: 208 TP C18

Thermo Fisher Scientific: BioBasic 18

Phenomenex: Jupiter 300 C18