Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Pinnacle DB Aqueous C18 Columns (USP L1)

Stationary Phase Category: modified C18 (L1)
Ligand Type: proprietary polar modified and functionally bonded C18
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ordering Notes

Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.

Before you order, consider experiencing Selectivity Accelerated with Raptor SPP Core-Shell LC Columns.
Documentation and Instructions Sheets

Pinnacle DB Aqueous C18 Columns (USP L1)

Catalog # 9418252

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9418252 2.1 mm 50 mm 1.9 µm ea. Select Deselect

Catalog # 9418252

ID
2.1 mm  
Length
50 mm  
Particle Size
1.9 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418212 2.1 mm 100 mm 1.9 µm ea. Select Deselect

Catalog # 9418212

ID
2.1 mm  
Length
100 mm  
Particle Size
1.9 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418232 2.1 mm 30 mm 1.9 µm ea. Select Deselect

Catalog # 9418232

ID
2.1 mm  
Length
30 mm  
Particle Size
1.9 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418312 2.1 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9418312

ID
2.1 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418315 4.6 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9418315

ID
4.6 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941831E 3.0 mm 100 mm 3 µm ea. Select Deselect

Catalog # 941831E

ID
3.0 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418332 2.1 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9418332

ID
2.1 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418335 4.6 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9418335

ID
4.6 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941833E 3.0 mm 30 mm 3 µm ea. Select Deselect

Catalog # 941833E

ID
3.0 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418352 2.1 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9418352

ID
2.1 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418355 4.6 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9418355

ID
4.6 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941835E 3.0 mm 50 mm 3 µm ea. Select Deselect

Catalog # 941835E

ID
3.0 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418362 2.1 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9418362

ID
2.1 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418365 4.6 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9418365

ID
4.6 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941836E 3.0 mm 150 mm 3 µm ea. Select Deselect

Catalog # 941836E

ID
3.0 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418512 2.1 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9418512

ID
2.1 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418515 4.6 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9418515

ID
4.6 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941851E 3.0 mm 100 mm 5 µm ea. Select Deselect

Catalog # 941851E

ID
3.0 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418522 2.1 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9418522

ID
2.1 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418525 4.6 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9418525

ID
4.6 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941852E 3.0 mm 200 mm 5 µm ea. Select Deselect

Catalog # 941852E

ID
3.0 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418532 2.1 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9418532

ID
2.1 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418535 4.6 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9418535

ID
4.6 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941853E 3.0 mm 30 mm 5 µm ea. Select Deselect

Catalog # 941853E

ID
3.0 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418552 2.1 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9418552

ID
2.1 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418555 4.6 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9418555

ID
4.6 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941855E 3.0 mm 50 mm 5 µm ea. Select Deselect

Catalog # 941855E

ID
3.0 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418562 2.1 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9418562

ID
2.1 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418565 4.6 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9418565

ID
4.6 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941856E 3.0 mm 150 mm 5 µm ea. Select Deselect

Catalog # 941856E

ID
3.0 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418572 2.1 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9418572

ID
2.1 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
9418575 4.6 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9418575

ID
4.6 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  
941857E 3.0 mm 250 mm 5 µm ea. Select Deselect

Catalog # 941857E

ID
3.0 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB Aqueous C18  

Pinnacle DB columns are 100% manufactured by Restek in our Bellefonte, Pennsylvania facility. Because performance begins with the support, our Pinnacle DB UHPLC columns start with base-deactivated spherical silica that is optimized for UHPLC stability. From there, we bond them with a wide variety of phases to give chromatographers a stable and selective column. Get the most out of your UHPLC system. Combine selectivity and efficiency by using Restek Pinnacle DB UHPLC columns.
The Restek Aqueous C18 is a rugged, reversed-phase column with a well-balanced retention profile. It can effectively retain more types of solutes than a conventional C18 and is ideal for multicomponent LC-MS analyses. The general-purpose Aqueous C18 boasts high reproducibility and compatibility with many mobile phase conditions—even 100% aqueous. And when used with a gradient, it eliminates the all-too-common issue of multiple compounds eluting near the column void time.
Stationary Phase Category: modified C18 (L1)
Ligand Type: proprietary polar modified and functionally bonded C18
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C