Pinnacle DB PFP Propyl Columns (USP L43)

Stationary Phase Category: fluorophenyl propyl (L43)
Ligand Type: pentafluorophenyl propyl
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ordering Notes

Certificates of analysis for new Restek LC columns are now provided electronically. To view and download, visit www.restek.com/documentation then enter your cat.# and serial #.

Before you order, consider experiencing Selectivity Accelerated with Raptor SPP Core-Shell LC Columns.
Documentation and Instructions Sheets

Pinnacle DB PFP Propyl Columns (USP L43)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
9419212 2.1 mm 100 mm 1.9 µm ea. Select Deselect

Catalog # 9419212

ID
2.1 mm  
Length
100 mm  
Particle Size
1.9 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419232 2.1 mm 30 mm 1.9 µm ea. Select Deselect

Catalog # 9419232

ID
2.1 mm  
Length
30 mm  
Particle Size
1.9 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419252 2.1 mm 50 mm 1.9 µm ea. Select Deselect

Catalog # 9419252

ID
2.1 mm  
Length
50 mm  
Particle Size
1.9 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419312 2.1 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9419312

ID
2.1 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419315 4.6 mm 100 mm 3 µm ea. Select Deselect

Catalog # 9419315

ID
4.6 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941931E 3.0 mm 100 mm 3 µm ea. Select Deselect

Catalog # 941931E

ID
3.0 mm  
Length
100 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419332 2.1 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9419332

ID
2.1 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419335 4.6 mm 30 mm 3 µm ea. Select Deselect

Catalog # 9419335

ID
4.6 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941933E 3.0 mm 30 mm 3 µm ea. Select Deselect

Catalog # 941933E

ID
3.0 mm  
Length
30 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419352 2.1 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9419352

ID
2.1 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419355 4.6 mm 50 mm 3 µm ea. Select Deselect

Catalog # 9419355

ID
4.6 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941935E 3.0 mm 50 mm 3 µm ea. Select Deselect

Catalog # 941935E

ID
3.0 mm  
Length
50 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419362 2.1 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9419362

ID
2.1 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419365 4.6 mm 150 mm 3 µm ea. Select Deselect

Catalog # 9419365

ID
4.6 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941936E 3.0 mm 150 mm 3 µm ea. Select Deselect

Catalog # 941936E

ID
3.0 mm  
Length
150 mm  
Particle Size
3 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419512 2.1 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9419512

ID
2.1 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419515 4.6 mm 100 mm 5 µm ea. Select Deselect

Catalog # 9419515

ID
4.6 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941951E 3.0 mm 100 mm 5 µm ea. Select Deselect

Catalog # 941951E

ID
3.0 mm  
Length
100 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419522 2.1 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9419522

ID
2.1 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419525 4.6 mm 200 mm 5 µm ea. Select Deselect

Catalog # 9419525

ID
4.6 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941952E 3.0 mm 200 mm 5 µm ea. Select Deselect

Catalog # 941952E

ID
3.0 mm  
Length
200 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419532 2.1 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9419532

ID
2.1 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419535 4.6 mm 30 mm 5 µm ea. Select Deselect

Catalog # 9419535

ID
4.6 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941953E 3.0 mm 30 mm 5 µm ea. Select Deselect

Catalog # 941953E

ID
3.0 mm  
Length
30 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419552 2.1 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9419552

ID
2.1 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419555 4.6 mm 50 mm 5 µm ea. Select Deselect

Catalog # 9419555

ID
4.6 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941955E 3.0 mm 50 mm 5 µm ea. Select Deselect

Catalog # 941955E

ID
3.0 mm  
Length
50 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419562 2.1 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9419562

ID
2.1 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419565 4.6 mm 150 mm 5 µm ea. Select Deselect

Catalog # 9419565

ID
4.6 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941956E 3.0 mm 150 mm 5 µm ea. Select Deselect

Catalog # 941956E

ID
3.0 mm  
Length
150 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419572 2.1 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9419572

ID
2.1 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
9419575 4.6 mm 250 mm 5 µm ea. Select Deselect

Catalog # 9419575

ID
4.6 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  
941957E 3.0 mm 250 mm 5 µm ea. Select Deselect

Catalog # 941957E

ID
3.0 mm  
Length
250 mm  
Particle Size
5 µm  
Units
ea.  
Pore Size
140 Å  
Product Name
Pinnacle DB PFP Propyl  

Pinnacle DB columns are 100% manufactured by Restek in our Bellefonte, Pennsylvania facility. Because performance begins with the support, our Pinnacle DB UHPLC columns start with base-deactivated spherical silica that is optimized for UHPLC stability. From there, we bond them with a wide variety of phases to give chromatographers a stable and selective column. Get the most out of your UHPLC system. Combine selectivity and efficiency by using Restek Pinnacle DB UHPLC columns.
The Restek PFP Propyl is a great choice for the retention and selectivity of charged bases, electronegative compounds, and amine-containing compounds. Unlike a conventional cyano column, the Restek PFP Propyl is much more amenable to LC-MS because it is more reliable and efficient with acidic mobile phases. This versatile column is also compatible with highly aqueous mobile phases and HILIC separations.
Stationary Phase Category: fluorophenyl propyl (L43)
Ligand Type: pentafluorophenyl propyl
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C