Canadian Pesticide Kit

  • Convenient, 96-compound kit contains only the compounds required by Canadian cannabis regulations, saving time and reducing cost.
  • Two independently produced lots available.
  • Verified composition and stability ensures long lasting shelf life.
  • Can be used to meet other government or in-house method requirements.

This kit contains one ampul of each of the following:
Canadian Pesticide Standard #1 (cat.# 32593)
Canadian Pesticide Standard #2 (cat.# 32594)
Canadian Pesticide Standard #3 (cat.# 32595)
Canadian Pesticide Standard #4 (cat.# 32596)
Canadian Pesticide Standard #5 (cat.# 32597)
Canadian Pesticide Standard #6 (cat.# 32598)
Azadirachtin Standard (cat.# 32599)
Dichlorvos Standard (cat.# 32585)

Certified reference materials (CRMs) manufactured and QC tested in ISO-accredited labs satisfy your ISO requirements.

Canadian Pesticide Kit

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
32592 Canadian Pesticide Kit 1 mL/ampul, 8 ampuls/kit kit Select Deselect

Catalog # 32592

Product Name
Canadian Pesticide Kit  
Conc. in Solvent and Volume
1 mL/ampul, 8 ampuls/kit  
Units
kit  
Certified Reference Material (CRM)
Yes  
Max Shelf Life on Ship Date
14 months  
Min Shelf Life on Ship Date*
6 months  
Shipping Conditions
Ambient  
Storage Temperature
–20 °C or colder  
For more information about storage and shipment temperatures, see our FAQ.
*Have specific minimum (min.) shelf- life requirements? Contact us

    Contains 1 ampul of each of the following. 100 μg/mL, Acetonitrile, 1 mL/ampul

    Cat.# 32593: Canadian Pesticide Standard #1
    Aldicarb (116-06-3)
    Bifenazate (149877-41-8)
    Carbaryl (sevin) (63-25-2)
    Carbofuran (1563-66-2)
    Fenoxycarb (72490-01-8)
    Iprodione (36734-19-7)
    Methiocarb (2032-65-7)
    Methomyl (16752-77-5)
    Novaluron (116714-46-6)
    Oxamyl (23135-22-0)
    Pirimicarb (23103-98-2)
    Propoxur (baygon) (114-26-1)
    Pyraclostrobin (175013-18-0)
    Teflubenzuron (83121-18-0)
    Thiophanate-methyl (23564-05-8)

    Cat.# 32594: Canadian Pesticide Standard #2
    Acephate (30560-19-1)
    Chlorpyrifos (2921-88-2)
    Coumaphos (56-72-4)
    Diazinon (333-41-5)
    Dimethoate (60-51-5)
    Ethoprophos (13194-48-4)
    Fensulfothion (115-90-2)
    Fenthion (55-38-9)
    Malathion (121-75-5)
    Methyl parathion (298-00-0)
    Mevinphos (7786-34-7)
    Naled (300-76-5)
    Phosmet (732-11-6)
    Tetrachlorvinphos (22248-79-9)

    Cat.# 32595: Canadian Pesticide Standard #3
    Abamectin (71751-41-2)
    Allethrin (584-79-2)
    Bifenthrin (82657-04-3)
    Cyfluthrin (68359-37-5)
    Cypermethrin (52315-07-8)
    Deltamethrin (52918-63-5)
    Etofenprox (80844-07-1)
    Fenvalerate (51630-58-1)
    Permethrin (cis & trans) (52645-53-1)
    Phenothrin (cis & trans) (26002-80-2)
    Prallethrin (23031-36-9)
    Pyrethrins (8003-34-7)
    Resmethrin (10453-86-8)
    Spinetoram (J&L) (935545-74-7)
    Spinosad (168316-95-8)
    Spirodiclofen (148477-71-8)
    Spiromesifen (283594-90-1)
    Tetramethrin (7696-12-0)

    Cat.# 32596: Canadian Pesticide Standard #4
    Azoxystrobin (131860-33-8)
    Chlorfenapyr (122453-73-0)
    Clofentezine (74115-24-5)
    Cyprodinil (121552-61-2)
    Daminozide (1596-84-5)
    Etoxazole (153233-91-1)
    Etridiazole (2593-15-9)
    Fenpyroximate (111812-58-9)
    Fipronil (120068-37-3)
    Fludioxonil (131341-86-1)
    Imazalil (35554-44-0)
    Myclobutanil (88671-89-0)
    Paclobutrazol (76738-62-0)
    Propiconazole (Tilt) (60207-90-1)
    Pyridaben (96489-71-3)
    Tebuconazole (107534-96-3)

    Cat.# 32597: Canadian Pesticide Standard #5
    Benzovindiflupyr (1072957-71-1)
    Boscalid (188425-85-6)
    Buprofezin (69327-76-0)
    Chlorantraniliprole (500008-45-7)
    Clothianidin (210880-92-5)
    Cyantraniliprole (736994-63-1)
    Dimethomorph (110488-70-5)
    Dinotefuran (165252-70-0)
    Flonicamid (158062-67-0)
    Fluopyram (658066-35-4)
    Hexythiazox (78587-05-0)
    Imidacloprid (138261-41-3)
    Metalaxyl (57837-19-1)
    Pentachloronitrobenzene (82-68-8)
    Spirotetramat (203313-25-1)
    Tebufenozide (112410-23-8)
    Thiamethoxam (153719-23-4)

    Cat.# 32598: Canadian Pesticide Standard #6
    Acequinocyl (57960-19-7)
    Acetamiprid (135410-20-7)
    Dodemorph (1593-77-7)
    Endosulfan I (959-98-8)
    Endosulfan II (33213-65-9)
    Endosulfan sulfate (1031-07-8)
    Kinoprene (42588-37-4)
    Kresoxim methyl (143390-89-0)
    Methoprene (40596-69-8)
    MGK-264 (113-48-4)
    Piperonyl butoxide (51-03-6)
    Spiroxamine (118134-30-8)
    Thiacloprid (111988-49-9)
    Trifloxystrobin (141517-21-7)

    Cat.# 32599: Azadirachtin Standard
    Azadirachtin (11141-17-6)

    Cat.# 32585: Dichlorvos Standard
    Dichlorvos (DDVP) (62-73-7)