8260A Volatile Organics Kit (2,000 µg/mL)

Contains 1 mL each of these mixtures.
30042: 502.2 Calibration Mix #1
30043: 502.2 Calibration Mix #2
30044: 502.2 Calibration Mix #3
30045: 502.2 Calibration Mix #4
30046: 502.2 Calibration Mix #5
30047: 502.2 Calibration Mix #6
30067: 4-bromofluorobenzene (2,500 µg/mL)
30240: 8260A Surrogate Mix (2,500 µg/mL)
30241: 8260A Internal Standard Mix (2,500 µg/mL)
30075: 8240/8260 System Performance Check Mix
30005: VOA Matrix Spike Mix (2,500 µg/mL)
Certified reference materials (CRMs) manufactured and QC tested in ISO-accredited labs satisfy your ISO requirements.

8260A Volatile Organics Kit (2,000 µg/mL)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
30242 kit Contains 1 mL each of these mixtures. 8260A Volatile Organics Kit Select Deselect

Catalog # 30242

Units
kit  
Conc. in Solvent and Volume
Contains 1 mL each of these mixtures.  
Product Name
8260A Volatile Organics Kit  
Certified Reference Material (CRM)
Yes  
Min Shelf Life on Ship Date*
6 months  
Shipping Conditions
Ambient  
Storage Temperature
0 °C or colder  
For more information about storage and shipment temperatures, see our FAQ.
*Have specific minimum (min.) shelf- life requirements? Contact us

    30042: 502.2 Calibration Mix #1 (gases)
    Bromomethane (methyl bromide) (74-83-9)
    Chloroethane (ethyl chloride) (75-00-3)
    Chloromethane (methyl chloride) (74-87-3)
    Dichlorodifluoromethane (CFC-12) (75-71-8)
    Trichlorofluoromethane (CFC-11) (75-69-4)
    Vinyl chloride (75-01-4)

    30043: 502.2 Calibration Mix #2
    Bromodichloromethane (75-27-4)
    Bromoform (75-25-2)
    Carbon tetrachloride (56-23-5)
    Chloroform (67-66-3)
    1,1-Dichloroethane (75-34-3)
    1,1-Dichloroethene (75-35-4)
    trans-1,2-Dichloroethene (156-60-5)
    1,3-Dichloropropane (142-28-9)
    2,2-Dichloropropane (594-20-7)
    cis-1,3-Dichloropropene (10061-01-5)
    trans-1,3-Dichloropropene (10061-02-6)
    Methylene chloride (dichloromethane) (75-09-2)
    1,1,1-Trichloroethane (71-55-6)
    Trichloroethene (79-01-6)

    30044: 502.2 Calibration Mix #3
    Bromochloromethane (74-97-5)
    Dibromochloromethane (124-48-1)
    1,2-Dibromo-3-chloropropane (96-12-8)
    1,2-Dibromoethane (EDB) (106-93-4)
    Dibromomethane (74-95-3)
    1,2-Dichloroethane (107-06-2)
    cis-1,2-Dichloroethene (156-59-2)
    1,2-Dichloropropane (78-87-5)
    1,1-Dichloropropene (563-58-6)
    1,1,1,2-Tetrachloroethane (630-20-6)
    1,1,2,2-Tetrachloroethane (79-34-5)
    Tetrachloroethene (127-18-4)
    1,1,2-Trichloroethane (79-00-5)
    1,2,3-Trichloropropane (96-18-4)

    30045: 502.2 Calibration Mix #4
    Benzene (71-43-2)
    tert-Butylbenzene (98-06-6)
    Chlorobenzene (108-90-7)
    Isopropylbenzene (cumene) (98-82-8)
    n-Propylbenzene (103-65-1)
    Styrene (100-42-5)
    Toluene (108-88-3)
    1,3,5-Trimethylbenzene (108-67-8)
    m-Xylene (108-38-3)

    30046: 502.2 Calibration Mix #5
    Bromobenzene (108-86-1)
    n-Butylbenzene (104-51-8)
    sec-Butylbenzene (135-98-8)
    2-Chlorotoluene (95-49-8)
    1,3-Dichlorobenzene (541-73-1)
    Ethylbenzene (100-41-4)
    1,2,4-Trichlorobenzene (120-82-1)
    1,2,4-Trimethylbenzene (95-63-6)
    o-Xylene (95-47-6)
    p-Xylene (106-42-3)

    30047: 502.2 Calibration Mix #6
    4-Chlorotoluene (106-43-4)
    1,2-Dichlorobenzene (95-50-1)
    1,4-Dichlorobenzene (106-46-7)
    Hexachlorobutadiene (87-68-3)
    4-Isopropyltoluene (p-Cymene) (99-87-6)
    Naphthalene (91-20-3)
    1,2,3-Trichlorobenzene (87-61-6)

    30067: 1-Bromo-4-fluorobenzene (BFB)
    1-Bromo-4-fluorobenzene (BFB) (460-00-4)

    30240: 8260A Surrogate Mix
    1-Bromo-4-fluorobenzene (BFB) (460-00-4)
    Dibromofluoromethane (1868-53-7)
    1,2-Dichloroethane-d4 (17060-07-0)
    Toluene-d8 (2037-26-5)

    30241: 8260A Internal Standard Mix
    Chlorobenzene-d5 (3114-55-4)
    1,4-Dichlorobenzene-d4 (3855-82-1)
    Fluorobenzene (462-06-6)

    30075: 8240/8260 System Performance Check Mix
    Bromoform (75-25-2)
    Chlorobenzene (108-90-7)
    Chloromethane (methyl chloride) (74-87-3)
    1,1-Dichloroethane (75-34-3)
    1,1,2,2-Tetrachloroethane (79-34-5)

    30005: VOA Matrix Spike Mix
    Benzene (71-43-2)
    Chlorobenzene (108-90-7)
    1,1-Dichloroethene (75-35-4)
    Toluene (108-88-3)
    Trichloroethene (79-01-6)

Changes in this revision of the method include modification of the recommended internal standard and surrogate solutions.