8270 MegaMix Standard (76 components)

  • Fewest mixtures needed for calibration and matrix spikes.
  • Mixtures formulated for maximum stability.
  • Contains most routinely analyzed compounds.

Simplify calibration with SVOC MegaMix reference standards kits that contain 150 (cat.# 31907) or 100 (cat.# 31908) of the most frequently analyzed semivolatiles.

Certified reference materials (CRMs) manufactured and QC tested in ISO-accredited labs satisfy your ISO requirements.

8270 MegaMix Standard (76 components)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
31850 8270 MegaMix 1000 µg/mL each in methylene chloride (3-methylphenol and 4-methylphenol at 500 µg/mL), 1 mL/ampul ea. Select Deselect

Catalog # 31850

Product Name
8270 MegaMix  
Conc. in Solvent and Volume
1000 µg/mL each in methylene chloride (3-methylphenol and 4-methylphenol at 500 µg/mL), 1 mL/ampul  
Units
ea.  
Certified Reference Material (CRM)
Yes  
Max Shelf Life on Ship Date
18 months  
Min Shelf Life on Ship Date*
6 months  
Shipping Conditions
Ambient  
Storage Temperature
0 °C or colder  
For more information about storage and shipment temperatures, see our FAQ.
*Have specific minimum (min.) shelf- life requirements? Contact us

    Acenaphthene (83-32-9)
    Acenaphthylene (208-96-8)
    Aniline (62-53-3)
    Anthracene (120-12-7)
    Azobenzene (103-33-3)*
    Benz[a]anthracene (56-55-3)
    Benzo[a]pyrene (50-32-8)
    Benzo[b]fluoranthene (205-99-2)
    Benzo[g,h,i]perylene (191-24-2)
    Benzo[k]fluoranthene (207-08-9)
    Benzyl alcohol (100-51-6)
    Benzyl butyl phthalate (85-68-7)
    Bis(2-chloroethoxy)methane (111-91-1)
    Bis(2-chloroethyl)ether (111-44-4)
    Bis(2-ethylhexyl)adipate (103-23-1)
    Bis(2-ethylhexyl)phthalate (117-81-7)
    4-Bromophenyl phenyl ether (101-55-3)
    Carbazole (86-74-8)
    4-Chloroaniline (106-47-8)
    4-Chloro-3-methylphenol (59-50-7)
    2-Chloronaphthalene (91-58-7)
    2-Chlorophenol (95-57-8)
    4-Chlorophenyl phenyl ether (7005-72-3)
    Chrysene (218-01-9)
    Dibenz[a,h]anthracene (53-70-3)
    Dibenzofuran (132-64-9)
    1,2-Dichlorobenzene (95-50-1)
    1,3-Dichlorobenzene (541-73-1)
    1,4-Dichlorobenzene (106-46-7)
    2,4-Dichlorophenol (120-83-2)
    Diethylphthalate (84-66-2)
    2,4-Dimethylphenol (105-67-9)
    Dimethylphthalate (131-11-3)
    Di-n-butyl phthalate (84-74-2)
    1,2-Dinitrobenzene (528-29-0)
    1,3-Dinitrobenzene (99-65-0)
    1,4-Dinitrobenzene (100-25-4)
    4,6-Dinitro-2-methylphenol (Dinitro-o-cresol) (534-52-1)
    2,4-Dinitrophenol (51-28-5)
    2,4-Dinitrotoluene (121-14-2)
    2,6-Dinitrotoluene (606-20-2)
    Di-n-octyl phthalate (117-84-0)
    Diphenylamine (122-39-4)†
    Fluoranthene (206-44-0)
    Fluorene (86-73-7)
    Hexachlorobenzene (118-74-1)
    Hexachlorobutadiene (87-68-3)
    Hexachlorocyclopentadiene (77-47-4)
    Hexachloroethane (67-72-1)
    Indeno[1,2,3-cd]pyrene (193-39-5)
    Isophorone (78-59-1)
    1-Methylnaphthalene (90-12-0)
    2-Methylnaphthalene (91-57-6)
    2-Methylphenol (o-cresol) (95-48-7)
    3-Methylphenol (m-cresol) (108-39-4)
    4-Methylphenol (p-cresol) (106-44-5)
    Naphthalene (91-20-3)
    2-Nitroaniline (88-74-4)
    3-Nitroaniline (99-09-2)
    4-Nitroaniline (100-01-6)
    Nitrobenzene (98-95-3)
    2-Nitrophenol (88-75-5)
    4-Nitrophenol (100-02-7)
    N-Nitrosodimethylamine (62-75-9)
    N-Nitroso-di-n-propylamine (621-64-7)
    2,2'-Oxybis(1-chloropropane) (108-60-1)
    Pentachlorophenol (87-86-5)
    Phenanthrene (85-01-8)
    Phenol (108-95-2)
    Pyrene (129-00-0)
    Pyridine (110-86-1)
    2,3,4,6-Tetrachlorophenol (58-90-2)
    2,3,5,6-Tetrachlorophenol (935-95-5)
    1,2,4-Trichlorobenzene (120-82-1)
    2,4,5-Trichlorophenol (95-95-4)
    2,4,6-Trichlorophenol (88-06-2)

*1,2-diphenylhydrazine (8270-listed analyte) decomposes to azobenzene (mix component) in the injector.
†N-nitrosodiphenylamine (8270-listed analyte) decomposes to diphenylamine (mix component) in the injector.