Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

LC Multiresidue Pesticide Standard #4 (63 components)

Organonitrogen Compounds

Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.

Ampul 4 of 10 in the LC-MS/MS Multiresidue Pesticide Standard Kit. Other ampuls also sold separately.
Certified reference materials (CRMs) manufactured and QC tested in ISO-accredited labs satisfy your ISO requirements.

LC Multiresidue Pesticide Standard #4 (63 components)

Catalog # 31975

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
31975 LC Multiresidue Pesticide Standard #4 100 µg/mL each in acetonitrile, 1 mL/ampul ea. Select Deselect

Catalog # 31975

Product Name
LC Multiresidue Pesticide Standard #4  
Conc. in Solvent and Volume
100 µg/mL each in acetonitrile, 1 mL/ampul  
Units
ea.  
Certified Reference Material (CRM)
Yes  
Max Shelf Life on Ship Date
12 months  
Min Shelf Life on Ship Date*
3 months  
Shipping Conditions
On Ice  
Storage Temperature
–20 °C or colder  
For more information about storage and shipment temperatures, see our FAQ.
*Have specific minimum (min.) shelf- life requirements? Contact us

    Abamectin (71751-41-2)
    Acetamiprid (135410-20-7)
    Ametryn (834-12-8)
    Amitraz (33089-61-1)
    Azoxystrobin (131860-33-8)
    Benalaxyl (71626-11-4)
    Benzoximate (29104-30-1)
    Boscalid (188425-85-6)
    Butafenacil (134605-64-4)
    Carbetamide (16118-49-3)
    Carfentrazone ethyl (128639-02-1)
    Chlorantraniliprole (500008-45-7)
    Clofentezine (74115-24-5)
    Cymoxanil (57966-95-7)
    Cyprodinil (121552-61-2)
    Cyromazine (66215-27-8)
    Dimoxystrobin (149961-52-4)
    Dinotefuran (165252-70-0)
    Doramectin (117704-25-3)
    Eprinomectin (123997-26-2)
    Famoxadon (131807-57-3)
    Fenazaquin (120928-09-8)
    Fenhexamid (126833-17-8)
    Fenpyroximate (111812-58-9)
    Flonicamid (158062-67-0)
    Fluazinam** (79622-59-6)
    Fludioxonil (131341-86-1)
    Fluoxastrobin (361377-29-9)
    Flutolanil (66332-96-5)
    Furalaxyl (57646-30-7)
    Halofenozide (112226-61-6)
    Imazalil (35554-44-0)
    Imidacloprid (138261-41-3)
    Ivermectin (70288-86-7)
    Kresoxim methyl (143390-89-0)
    Mandipropamid (374726-62-2)
    Mepanipyrim (110235-47-7)
    Mepronil (55814-41-0)
    Metaflumizone (139968-49-3)
    Metalaxyl (57837-19-1)
    Methoxyfenozide (161050-58-4)
    Moxidectin (113507-06-5)
    Myclobutanil (88671-89-0)
    Nitenpyram (120738-89-8)
    Oxadixyl (77732-09-3)
    Picoxystrobin (117428-22-5)
    Piperonyl butoxide (51-03-6)
    Prochloraz (67747-09-5)
    Prometon (1610-18-0)
    Pymetrozine (123312-89-0)
    Pyracarbolid (24691-76-7)
    Pyrimethanil (53112-28-0)
    Pyriproxyfen (95737-68-1)
    Quinoxyfen (124495-18-7)
    Rotenone (83-79-4)
    Secbumeton (26259-45-0)
    Spiroxamine (118134-30-8)
    Tebufenozide (112410-23-8)
    Tebufenpyrad (119168-77-3)
    Terbumeton (33693-04-8)
    Triadimefon (43121-43-3)
    Trifloxystrobin (141517-21-7)
    Zoxamide (156052-68-5)

  • Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.
  • Formulated and grouped for maximum long-term stability* and well-balanced chromatographic performance.
  • Quantitatively tested to confirm composition; detailed support documentation provided.
  • Optimized multiresidue pesticide method is offered free of charge; downloadable XLS file includes conditions and transition tables.
  • Full 204-compound kit also available (cat.# 31971) that covers many LC-determined pesticides listed by government agencies; other ampuls also sold separately.
  • Certified reference material (CRM) manufactured and QC-tested in Restek’s ISO-accredited labs satisfies your ISO requirements.
  • Restek is your complete supplier for world-class LC-MS/MS multiresidue pesticide analysis: reference and internal standards, Ultra and Pinnacle DB LC columns, Q-sep QuEChERS sample prep products, accessories, and more!

* Note: When combining a large number of compounds with different chemical functionalities, mix stability can be an issue. In formulating these standards, we extensively studied the 204 compounds involved, and then grouped them into as few mixes as possible while still ensuring maximum long-term stability and reliability. For quantitative analysis, we recommend analyzing each mix separately to ensure accurate results for every compound.

** Note: In this standard, fluazinam should only be used for qualitative analysis. A single-component standard (cat.# 31982) is available for quantitative analysis.