Sample Cylinders, High Pressure (Stainless Steel & Sulfinert Treated)

  • 304 L stainless steel to resist corrosion.
  • DOT-3E rating (up to/including 500 cc) and DOT-3A (over 500 cc) to 1800 psig (TPED cylinders to 1450 psig), which allows sampling at gas wellheads as well as on-site refineries.
  • Range of cylinder sizes: 75 cc – 2250 cc.
  • Stated pressure ratings are at 100 °F (37 °C).
  • All cylinders have 1/4" female NPT threads on both ends.
  • TPED-compliant cylinders available for EU community.
  • Each cylinder is hydrostatically tested to at least 5/3 times the working pressure.
Documentation and Instructions Sheets

Sample Cylinders, High Pressure (Stainless Steel & Sulfinert Treated)

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
21394 304 L Stainless Steel, Sulfinert Treated 1800 psig 2250 cc ea. Sample Cylinder Select Deselect

Catalog # 21394

Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1800 psig  
Volume
2250 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
4.00" (102 mm)  
Length
17.2" (437 mm)  
Wall Thickness
0.206" (5.2 mm)  
Weight
14 lb (6.4 kg)  
21394-PI TPED (Pi) compliant 304 L Stainless Steel, Sulfinert Treated 1450 psig 2250 cc ea. Sample Cylinder Select Deselect

Catalog # 21394-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1450 psig  
Volume
2250 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
3.960" (100.6 mm)  
Length
17.2" (437 mm)  
Wall Thickness
0.195" (4.95 mm)  
Weight
14 lb (6.4 kg)  
22921 304 L Stainless Steel 1800 psig 75 cc ea. Sample Cylinder Select Deselect

Catalog # 22921

Material
304 L Stainless Steel  
Max Pressure
1800 psig  
Volume
75 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.50" (38.1 mm)  
Length
4.94" (125 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
0.62 lb (0.28 kg)  
22921-PI TPED (Pi) compliant 304 L Stainless Steel 1450 psig 75 cc ea. Sample Cylinder Select Deselect

Catalog # 22921-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel  
Max Pressure
1450 psig  
Volume
75 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.485" (37.7 mm)  
Length
4.94" (125 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
0.62 lb (0.28 kg)  
22922 304 L Stainless Steel 1800 psig 150 cc ea. Sample Cylinder Select Deselect

Catalog # 22922

Material
304 L Stainless Steel  
Max Pressure
1800 psig  
Volume
150 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
2.00" (50.8 mm)  
Length
5.25" (133 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
0.94 lb (0.43 kg)  
22922-PI TPED (Pi) compliant 304 L Stainless Steel 1450 psig 150 cc ea. Sample Cylinder Select Deselect

Catalog # 22922-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel  
Max Pressure
1450 psig  
Volume
150 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.980" (50.3 mm)  
Length
5.25" (133 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
0.94 lb (0.43 kg)  
22923 304 L Stainless Steel 1800 psig 300 cc ea. Sample Cylinder Select Deselect

Catalog # 22923

Material
304 L Stainless Steel  
Max Pressure
1800 psig  
Volume
300 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
2.00" (50.8 mm)  
Length
8.94" (227 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
1.6 lb (0.73 kg)  
22923-PI TPED (Pi) compliant 304 L Stainless Steel 1450 psig 300 cc ea. Sample Cylinder Select Deselect

Catalog # 22923-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel  
Max Pressure
1450 psig  
Volume
300 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.980" (50.3 mm)  
Length
8.94" (227 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
1.6 lb (0.73 kg)  
22924 304 L Stainless Steel 1800 psig 500 cc ea. Sample Cylinder Select Deselect

Catalog # 22924

Material
304 L Stainless Steel  
Max Pressure
1800 psig  
Volume
500 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
2.00" (50.8 mm)  
Length
13.8" (351 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
2.6 lb (1.2 kg)  
22924-PI TPED (Pi) compliant 304 L Stainless Steel 1450 psig 500 cc ea. Sample Cylinder Select Deselect

Catalog # 22924-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel  
Max Pressure
1450 psig  
Volume
500 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.980" (50.3 mm)  
Length
13.8" (351 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
2.6 lb (1.2 kg)  
22925 304 L Stainless Steel 1800 psig 1000 cc ea. Sample Cylinder Select Deselect

Catalog # 22925

Material
304 L Stainless Steel  
Max Pressure
1800 psig  
Volume
1000 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
3.50" (88.9 mm)  
Length
10.9" (277 mm)  
Wall Thickness
0.18" (4.6 mm)  
Weight
6.5 lb (2.9 kg)  
22925-PI TPED (Pi) compliant 304 L Stainless Steel 1450 psig 1000 cc ea. Sample Cylinder Select Deselect

Catalog # 22925-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel  
Max Pressure
1450 psig  
Volume
1000 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
3.465" (88 mm)  
Length
10.9" (277 mm)  
Wall Thickness
0.170" (4.32 mm)  
Weight
6.5 lb (2.9 kg)  
22926 304 L Stainless Steel 1800 psig 2250 cc ea. Sample Cylinder Select Deselect

Catalog # 22926

Material
304 L Stainless Steel  
Max Pressure
1800 psig  
Volume
2250 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
4.00" (102 mm)  
Length
17.2" (437 mm)  
Wall Thickness
0.206" (5.2 mm)  
Weight
14 lb (6.4 kg)  
22926-PI TPED (Pi) compliant 304 L Stainless Steel 1450 psig 2250 cc ea. Sample Cylinder Select Deselect

Catalog # 22926-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel  
Max Pressure
1450 psig  
Volume
2250 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
3.960" (100.6 mm)  
Length
17.2" (437 mm)  
Wall Thickness
0.195" (4.95 mm)  
Weight
14 lb (6.4 kg)  
24130 304 L Stainless Steel, Sulfinert Treated 1800 psig 75 cc ea. Sample Cylinder Select Deselect

Catalog # 24130

Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1800 psig  
Volume
75 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.50" (38.1 mm)  
Length
4.94" (125 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
0.62 lb (0.28 kg)  
24130-PI TPED (Pi) compliant 304 L Stainless Steel, Sulfinert Treated 1450 psig 75 cc ea. Sample Cylinder Select Deselect

Catalog # 24130-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1450 psig  
Volume
75 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.485" (37.7 mm)  
Length
4.94" (125 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
0.62 lb (0.28 kg)  
24131 304 L Stainless Steel, Sulfinert Treated 1800 psig 150 cc ea. Sample Cylinder Select Deselect

Catalog # 24131

Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1800 psig  
Volume
150 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
2.00" (50.8 mm)  
Length
5.25" (133 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
0.94 lb (0.43 kg)  
24131-PI TPED (Pi) compliant 304 L Stainless Steel, Sulfinert Treated 1450 psig 150 cc ea. Sample Cylinder Select Deselect

Catalog # 24131-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1450 psig  
Volume
150 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.980" (50.3 mm)  
Length
5.25" (133 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
0.94 lb (0.43 kg)  
24132 304 L Stainless Steel, Sulfinert Treated 1800 psig 300 cc ea. Sample Cylinder Select Deselect

Catalog # 24132

Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1800 psig  
Volume
300 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
2.00" (50.8 mm)  
Length
8.94" (227 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
1.6 lb (0.73 kg)  
24132-PI TPED (Pi) compliant 304 L Stainless Steel, Sulfinert Treated 1450 psig 300 cc ea. Sample Cylinder Select Deselect

Catalog # 24132-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1450 psig  
Volume
300 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.980" (50.3 mm)  
Length
8.94" (227 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
1.6 lb (0.73 kg)  
24133 304 L Stainless Steel, Sulfinert Treated 1800 psig 500 cc ea. Sample Cylinder Select Deselect

Catalog # 24133

Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1800 psig  
Volume
500 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
2.00" (50.8 mm)  
Length
13.8" (351 mm)  
Wall Thickness
0.093" (2.4 mm)  
Weight
2.6 lb (1.2 kg)  
24133-PI TPED (Pi) compliant 304 L Stainless Steel, Sulfinert Treated 1450 psig 500 cc ea. Sample Cylinder Select Deselect

Catalog # 24133-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1450 psig  
Volume
500 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
1.980" (50.3 mm)  
Length
13.8" (351 mm)  
Wall Thickness
0.090" (2.29 mm)  
Weight
2.6 lb (1.2 kg)  
24134 304 L Stainless Steel, Sulfinert Treated 1800 psig 1000 cc ea. Sample Cylinder Select Deselect

Catalog # 24134

Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1800 psig  
Volume
1000 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
3.50" (88.9 mm)  
Length
10.9" (277 mm)  
Wall Thickness
0.18" (4.6 mm)  
Weight
6.5 lb (2.9 kg)  
24134-PI TPED (Pi) compliant 304 L Stainless Steel, Sulfinert Treated 1450 psig 1000 cc ea. Sample Cylinder Select Deselect

Catalog # 24134-PI

Certification/Compliance
TPED (Pi) compliant  
Material
304 L Stainless Steel, Sulfinert Treated  
Max Pressure
1450 psig  
Volume
1000 cc  
Units
ea.  
Product Name
Sample Cylinder  
Diameter
3.465" (88 mm)  
Length
10.9" (277 mm)  
Wall Thickness
0.170" (4.32 mm)  
Weight
6.5 lb (2.9 kg)