RAVEqc Quick-Connect Air Valves

  • Simplify your workflow—tool-free design makes it fast and easy for anyone to make consistent, quality connections.
  • Extend air canister and valve lifetime—no wrenches mean no overtightening or cross-threading damage.
  • Stand-alone or supporting roles—use alone or pair with a bellows/diaphragm valve for the ultimate in sample security and convenience.
  • Check status at a glance—if the parts are connected, the valve is open; if they’re apart, it’s closed. (Open-position valves also available.*)
  • Standard compression or tube end fittings accommodate a wide variety of air canisters and related devices.
  • Leak-free performance—each and every valve is helium leak tested to 1x10-6 mL/sec.
  • Compatible with Entech Micro-QT valves.

Note: A RAVEqc valve bracket is required for use with Restek 1, 3, 6, and 15 L air sampling canisters when using the compression fitting mounted directly on the 1/4" canister tube stub. This bracket is not needed when using Restek miniature canisters or Entech canisters.

Documentation and Instructions Sheets

RAVEqc Quick-Connect Air Valves

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
27341 2500 mL/min @ 29" Hg Stainless Steel ea. Female RAVEqc Valve to 1/16" Male Compression Fitting Select Deselect

Catalog # 27341

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/16" Male Compression Fitting  
Similar To
Entech FQT-100
27342 2500 mL/min @ 29" Hg Siltek Treated ea. Female RAVEqc Valve to 1/16" Male Compression Fitting Select Deselect

Catalog # 27342

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/16" Male Compression Fitting  
Similar To
Entech FQT-100S
27343 2500 mL/min @ 29" Hg Stainless Steel ea. Female RAVEqc Valve to 1/8" Male Compression Fitting Select Deselect

Catalog # 27343

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/8" Male Compression Fitting  
Similar To
Entech FQT-200
27344 2500 mL/min @ 29" Hg Siltek Treated ea. Female RAVEqc Valve to 1/8" Male Compression Fitting Select Deselect

Catalog # 27344

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/8" Male Compression Fitting  
Similar To
Entech FQT-200S
27345 3850 mL/min @ 29" Hg Stainless Steel ea. Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position Select Deselect

Catalog # 27345

Flow Capacity
3850 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position  
27346 3850 mL/min @ 29" Hg Siltek Treated ea. Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position Select Deselect

Catalog # 27346

Flow Capacity
3850 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting, High-Flow, Open-Position  
27347 2500 mL/min @ 29" Hg Stainless Steel ea. Female RAVEqc Valve to 1/4" Tube-End Fitting Select Deselect

Catalog # 27347

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" Tube-End Fitting  
Similar To
Entech FQT-T400
27348 2500 mL/min @ 29" Hg Siltek Treated ea. Female RAVEqc Valve to 1/4" Tube-End Fitting Select Deselect

Catalog # 27348

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" Tube-End Fitting  
Similar To
Entech FQT-T400S
27349 2500 mL/min @ 29" Hg Stainless Steel ea. Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge Select Deselect

Catalog # 27349

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge  
Similar To
Entech MQT-400L-D
27350 2500 mL/min @ 29" Hg Siltek Treated ea. Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge Select Deselect

Catalog # 27350

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting without Gauge  
Similar To
Entech MQT-400L-DS
27351 2500 mL/min @ 29" Hg Stainless Steel ea. Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge Select Deselect

Catalog # 27351

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge  
Similar To
Entech MQT-400L-G
27352 2500 mL/min @ 29" Hg Siltek Treated ea. Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge Select Deselect

Catalog # 27352

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Male RAVEqc 3-Port Valve to 1/4" Male Compression Fitting with Gauge  
Similar To
Entech MQT-400L-GS
27365 2500 mL/min @ 29" Hg Stainless Steel ea. Female RAVEqc Valve to 1/4" NPT Fitting Select Deselect

Catalog # 27365

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" NPT Fitting  
27366 2500 mL/min @ 29" Hg Siltek Treated ea. Female RAVEqc Valve to 1/4" NPT Fitting Select Deselect

Catalog # 27366

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" NPT Fitting  
27367 2500 mL/min @ 29" Hg Stainless Steel ea. Male RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27367

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Male RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Restek (Discontinued) 24185
Entech MQT-400
27368 2500 mL/min @ 29" Hg Siltek Treated ea. Male RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27368

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Male RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Restek (Discontinued) 24186
Entech MQT-400S
27369 2500 mL/min @ 29" Hg Stainless Steel ea. Female RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27369

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Restek (Discontinued) 24187
Entech FQT-400
27370 2500 mL/min @ 29" Hg Siltek Treated ea. Female RAVEqc Valve to 1/4" Male Compression Fitting Select Deselect

Catalog # 27370

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Female RAVEqc Valve to 1/4" Male Compression Fitting  
Similar To
Entech FQT-400S
27371 2500 mL/min @ 29" Hg Stainless Steel ea. Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58") Select Deselect

Catalog # 27371

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58")  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Similar To
Entech MQT-T400
27372 2500 mL/min @ 29" Hg Siltek Treated ea. Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58") Select Deselect

Catalog # 27372

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Extended (1.58")  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Similar To
Entech MQT-T400S
27373 2500 mL/min @ 29" Hg Stainless Steel ea. Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23") Select Deselect

Catalog # 27373

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Stainless Steel  
Units
ea.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23")  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Similar To
Entech MQT-ST400
27374 2500 mL/min @ 29" Hg Siltek Treated ea. Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23") Select Deselect

Catalog # 27374

Flow Capacity
2500 mL/min @ 29" Hg  
Material
Siltek Treated  
Units
ea.  
Product Name
Male RAVEqc Valve to 1/4" Tube End Fitting, Short (1.23")  
Note
Requires a 1/4" nut and ferrule set, sold separately in 5-pks. as cat.# 23161.  
Similar To
Entech MQT-ST400S

  • RAVEqc Quick-Connect air valves are a fast, easy, tool-free way to attach air canisters to the wide variety of devices used to sample and analyze air samples.
  • Restek Air Valve Excellence (RAVE) is a great family of products that upgrade your existing air canisters to improve reliability and performance.
  • Made in the U.S.A.
Valve Max Flow @ 29" Hg (mL/min)** 6 L Grab Sample Time (sec)
RAVEqc quick-connect air valve 2500 240
RAVEqc high-flow quick-connect air valve 3850 120
RAVE diaphragm valve 40,000 10
** Flow rates calculated on a 1/4" platform.

* Open-position option available to prevent vacuum/pressure from being trapped by the valve when desired (e.g., when using a vacuum/pressure gauge). High flow facilitates use with canister-cleaning ovens.