Resprep EPH Fractionation SPE Cartridge

  • Method-specific performance for extractable petroleum hydrocarbon (EPH) analysis of soil and water samples.
  • Complete separation of aliphatic and aromatic compounds into distinct fractions.
  • Guaranteed background level under the strict reporting limits of MA and NJ EPH methods.
  • Superior lot-to-lot reproducibility and storage stability ensured by rigorous QC testing and moisture-resistant packaging.
  • Choose 5 g cartridges for higher loading capacity; use 2 g cartridges for automated systems, time-saving, and solvent reduction.
Ordering Notes

Free samples of Resprep solid phase extraction (SPE) tubes are available! Contact us or your local Restek representative.

Certificates of analysis for this product are provided electronically. To view and download your certificate, simply visit www.restek.com/documentation

Documentation and Instructions Sheets

Resprep EPH Fractionation SPE Cartridge

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
23240 EPH Fractionation: Complete separation of aliphatic and aromatic hydrocarbons into distinct extract fractions. Guaranteed background level under MA and NJ EPH method limits. Silica packing. 15 mL, 5 g 15-pk. Resprep EPH Fractionation SPE Cartridge Select Deselect

Catalog # 23240

Method
EPH Fractionation: Complete separation of aliphatic and aromatic hydrocarbons into distinct extract fractions. Guaranteed background level under MA and NJ EPH method limits.  
Packing
Silica packing.  
Volume
15 mL, 5 g  
Units
15-pk.  
Product Name
Resprep EPH Fractionation SPE Cartridge  
Similar To
Restek (Discontinued) 25859
Restek (Discontinued) 26065
25999 EPH Fractionation: Complete separation of aliphatic and aromatic hydrocarbons into distinct extract fractions. Guaranteed background level under MA and NJ EPH method limits. Silica packing. 6 mL, 2 g 30-pk. Resprep EPH Fractionation SPE Cartridge Select Deselect

Catalog # 25999

Method
EPH Fractionation: Complete separation of aliphatic and aromatic hydrocarbons into distinct extract fractions. Guaranteed background level under MA and NJ EPH method limits.  
Packing
Silica packing.  
Volume
6 mL, 2 g  
Units
30-pk.  
Product Name
Resprep EPH Fractionation SPE Cartridge  

Restek EPH cartridges have a sample concentration loading capacity of 5000 ppm per gram silica for 5 g cartridges (total 25000 ppm) and 4250 ppm per gram of silica for 2 g cartridges (total of 8500 ppm), per instructions. However, to ensure satisfactory fractionation and avoid breakthrough, actual elution volumes should be determined empirically prior to sample analysis. The procedure in Restek’s product instruction sheet is suitable for MA and NJ method QC levels; however, high-concentration samples may require dilution or modified solvent volumes.