Your web browser will no longer be supported by Restek.com as of 30 June 2021.
To avoid any interruption in access or functionality, install a current-generation web browser now. Learn more.

Share:

Resprep CarboPrep Plus SPE Cartridges

  • Designed specifically for the cleanup of sample extracts for organochlorine pesticides analysis.
  • Excellent alternative to Florisil products, especially for the removal of nonvolatile matrix components that contaminate GC inlets and columns.
  • Proprietary treatment renders the carbon consistent and clean, ensuring the same selectivity tube to tube, and lot to lot with no interfering background.
  • Uses the same hardware, solvents, and solvent volumes as traditional Florisil cleanup, so switching is simple.
Ordering Notes

Certificates of analysis for this product are provided electronically. To view and download your certificate, simply visit www.restek.com/documentation

Documentation and Instructions Sheets

Resprep CarboPrep Plus SPE Cartridges

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Find a Distributor
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
25845 30-pk. 3 mL, 95 mg CarboPrep Plus Resprep CarboPrep Plus SPE Cartridges Select Deselect

Catalog # 25845

Units
30-pk.  
Volume
3 mL, 95 mg  
Packing
CarboPrep Plus  
Product Name
Resprep CarboPrep Plus SPE Cartridges  

Keep your organochlorine pesticide GCs up and running by protecting them against matrix components with superior sample cleanup. Resprep CarboPrep Plus SPE cartridges surpass traditional Florisil products in cleanup power for sample matrix compounds that cause active sites in GC inlets and columns, degrading pesticides and interrupting work due to failed calibration checks. For CarboPrep Plus cartridges, Restek uses a proprietary treatment to create an exceptionally clean carbon that exhibits consistent selectivity. The end result is a reliable sample preparation product that does not contribute interfering background signal and does not need to be evaluated lot to lot to see if elution volumes need to be adjusted. In addition, CarboPrep Plus cartridges are designed to use the same equipment, solvents, and solvent volumes as a traditional Florisil cleanup procedure, minimizing the impact of switching on sample prep labs while maximizing the performance benefit to analytical labs.