Resprep SLE Cartridges and 96-Well Plates

  • Faster and easier than SPE and liquid-liquid extraction: just load, wait 5 minutes, then elute.
  • Effective removal of proteins, phospholipids, and salts.
  • Quick concentration step increases sensitivity.
  • Easy to automate for high-throughput laboratories.
  • Suitable for a wide range of sample matrices and analyte pKa values.

Volume guidelines: Selecting an SLE format with sufficient loading capacity (1 mg sorbent to 1µL diluted sample) is very important because the entire sample volume (including 1:1 dilution in buffer) is absorbed into the diatomaceous earth sorbent. For example, a 100 µL sample should be diluted 1:1 with buffer for a total volume of 200 µL, which requires use of a 200 mg SLE product.

Ordering Notes

Certificates of analysis for this product are provided electronically. To view and download your certificate, simply visit www.restek.com/documentation

Documentation and Instructions Sheets

Resprep SLE Cartridges and 96-Well Plates

Catalog #

Select Catalog # below
Availability:
Price:
Total:
Contact us
Select Catalog # below

Product Options

Not sure which Restek product is the best for your analysis? Consult a Technical Specialist
Catalog # Clear All
28302 50-pk. Resprep SLE cartridges, 200 mg/3 mL cartridge Select Deselect

Catalog # 28302

Units
50-pk.  
Product Name
Resprep SLE cartridges, 200 mg/3 mL cartridge  
28303 50-pk. Resprep SLE cartridges, 400 mg/3 mL cartridge Select Deselect

Catalog # 28303

Units
50-pk.  
Product Name
Resprep SLE cartridges, 400 mg/3 mL cartridge  
28304 1-pk. Resprep SLE 96-well plates, 200 mg/2 mL each well Select Deselect

Catalog # 28304

Units
1-pk.  
Product Name
Resprep SLE 96-well plates, 200 mg/2 mL each well  
28305 1-pk. Resprep SLE 96-well plates, 400 mg/2 mL each well Select Deselect

Catalog # 28305

Units
1-pk.  
Product Name
Resprep SLE 96-well plates, 400 mg/2 mL each well  

Dilute-and-shoot is only effective when you are working with relatively clean matrices—complex biological samples, such as whole blood, require a cleanup step or your results may be inaccurate. Matrix components, such as proteins, phospholipids, and salts, introduce interferences and suppression/enhancement effects that compromise data integrity. Solid phase extraction (SPE) and liquid-liquid extraction are excellent ways to produce clean extracts, but they are time-consuming and not always necessary. Your first step in developing a sample preparation procedure should be supported liquid extraction (SLE); if your samples do not require extensive treatment, SLE cleanup is a quick, efficient, and fully automatable solution.