GC Column Cross-Reference
Columns by Phase
- Share:
Fused Silica GC Columns
Restek
|
Phase
Description |
USP
Nomenclature |
Agilent
|
SGE
|
Phenomenex
|
Machery-Nagel
|
Supelco
|
Alltech
|
Quadrex
|
dimethyl polysiloxane
|
G1, G2, G38
|
HP-1, DB-1,
CP-Sil 5 CB |
BP1
|
ZB-1
|
OPTIMA 1
|
SPB-1
|
AT-1,
EC-1 |
007-1
|
|
dimethyl polysiloxane
|
|
DB-1HT
|
|
ZB-1HTinferno
|
|
|
AT-1ht
|
|
|
dimethyl polysiloxane
(low bleed) |
G1, G2, G38
|
HP-1ms,
HP-1ms UI, DB-1ms, DB-1ms UI, VF-1ms, Ultra-1 |
BP1
|
ZB-1,
ZB-1ms |
OPTIMA 1 MS, OPTIMA 1 MS, Accent
|
SPB-1,
Equity-1 |
AT-1ms
|
007-1
|
|
diphenyl dimethyl polysiloxane
|
G27, G36
|
HP-5, DB-5,
CP-Sil 8 CB |
BP5
|
ZB-5
|
OPTIMA 5
|
SPB-5
|
EC-5,
AT-5 |
007-5
|
|
diphenyl dimethyl polysiloxane
|
|
DB-5ht,
VF-5ht |
HT5
|
ZB-5HTinferno
|
OPTIMA 5HT
|
|
|
|
|
diphenyl dimethyl
polysiloxane (low bleed) |
G27, G36
|
HP-5msSV,
HP-5ms, HP-5ms UI, DB-5, Ultra-2, CP-Sil 8 CB |
BP5ms
|
ZB-5,
ZB-5msi |
OPTIMA 5,
OPTIMA 5 MS |
SPB-5,
Equity-5 |
AT-5ms
|
007-5
|
|
1,4-bis(dimethylsiloxy)
phenylene dimethyl polysiloxane |
G27, G36
|
DB-5ms,
DB-5msUI, VF-5ms |
BPX5
|
ZB-5ms,
ZB-SemiVolatiles, ZM-5MS plus |
OPTIMA 5 MS Accent
|
SLB-5ms
|
|
007-5MS
|
|
proprietary phase
|
|
DB-XLB,
VF-Xms |
|
MR1, ZB-XLB
|
OPTIMA XLB
|
|
|
|
|
diphenyl dimethyl
polysiloxane |
G32
|
|
|
|
|
SPB-20
|
EC-20,
AT-20 |
007-20
|
|
diphenyl dimethyl
polysiloxane |
G42
|
HP-35, DB-35
|
|
ZB-35
|
|
SPB-35,
SPB-608 |
AT-35,
AT-35-ms |
007-35
|
|
proprietary phase
|
G42
|
DB-35ms, DB35msUI,
VF-35ms |
BPX35, BPX608
|
MR2
|
OPTIMA 35 MS
|
|
|
|
|
phenyl methyl
polysiloxane |
G3
|
HP-50+,
CP-Sil 24 CB |
|
|
|
SPB-50
|
AT-50
|
007-17
|
|
diphenyl dimethyl
polysiloxane |
G3
|
HP-17,
DB-17, DB-17ht, DB-608 |
|
ZB-50
|
OPTIMA 17
|
SPB-17
|
|
|
|
proprietary phase
|
G17
|
DB-17ms,
VF-17ms |
BPX50
|
|
OPTIMA 17 MS
|
|
|
|
|
proprietary phase
|
|
CP-TAP-CB
|
|
|
|
|
|
007-65HT |
|
diphenyl dimethyl
polysiloxane |
|
|
|
|
|
|
|
007-65HT
|
|
proprietary phase
|
G43
|
DB-624,
VF-624ms, CP-Select 624 CB |
BP624
|
|
OPTIMA 624 LB
|
|
|
|
|
silarylene-based cyano
|
G43
|
VF-1301ms
|
|
|
|
|
|
|
|
cyanopropylmethyl phenylmethyl
polysiloxane |
G43
|
DB-1301,
DB-624, DB-624UI, VF-1301ms, VF-624ms, CP-1301 |
BP624
|
ZB-624
|
OPTIMA 1301, OPTIMA 624
|
SPB-624
|
AT-624,
AT-1301 |
007-1301,
007-624 |
|
cyanopropylmethyl phenylmethyl
polysiloxane |
G46
|
DB-1701P,
DB-1701, CP-Sil 19 CB, VF-1701ms, VF-1701 Pesticides |
BP10
|
ZB-1701,
ZB-1701P |
OPTIMA 1701
|
Equity-1701
|
AT-1701
|
007-1701
|
|
trifluoropropylmethyl polysiloxane
|
G6
|
DB-210,
DB-200, VF-200ms |
|
|
OPTIMA 210
|
|
AT-210
|
|
|
trifluoropropylmethyl polysiloxane
(low bleed) |
G6
|
VF-200ms
|
|
|
|
|
|
|
|
cyanopropylmethyl phenylmethyl
polysiloxane |
G7, G19
|
DB-225ms,
CP-Sil 43 CB |
BP225
|
|
OPTIMA 225
|
SPB-225
|
AT-225
|
007-225
|
|
proprietary phase
|
Restek Innovation |
||||||||
biscyanopropyl cyanopropylphenyl
polysiloxane |
G5, G8, G48
|
VF-23ms
|
BPX70
|
|
|
SP-2330,
SP-2331, SP-2380 |
AT-Silar90
|
007-23
|
|
biscyanopropyl polysiloxane
|
G5
|
HP-88,
CP-Sil 88 |
|
|
|
SP-2560
|
|
|
|
proprietary phase
|
G51
|
Restek Innovation
|
|||||||
polyethylene glycol
|
G16, G20, G39
|
DB-Wax
|
BP20
|
ZB-Wax
|
OPTIMA WAX
|
|
AT-WAXms, EC-WAX
|
007-CW
|
|
polyethylene glycol
|
G16, G20, G39
|
HP-INNOWax,
CP-Wax 52 CB, VF-WAX MS |
|
ZB-WAXplus
|
OPTIMA WAXplus
|
Supelcowax-10
|
AT-WAX, EC-Wax
|
|
|
polyethylene glycol
|
|
|
|
|
|
|
AT-WAXms
|
|
MXT GC Columns
Restek
|
Phase
Description |
USP
Nomenclature |
Agilent
|
SGE
|
Phenomenex
|
Machery-Nagel
|
Supelco
|
Alltech
|
Quadrex
|
dimethyl polysiloxane
|
G1, G2, G38
|
HP-1, DB-1,
CP-Sil 5 CB |
BP1
|
ZB-1
|
OPTIMA 1
|
SPB-1
|
AT-1,
EC-1 |
007-1
|
|
diphenyl dimethyl polysiloxane
|
G27, G36
|
HP-5, DB-5,
CP-Sil 8 CB |
BP5
|
ZB-5
|
OPTIMA 5
|
SPB-5
|
EC-5, AT-5
|
007-5
|
|
phenyl methyl
polysiloxane |
G3
|
HP-50+,
CP-Sil 24 CB |
|
|
|
SPB-50
|
AT-50
|
007-17
|
|
proprietary phase
|
|
CP-TAP-CB
|
|
|
|
|
|
007-65HT
|
|
cyanopropylmethyl phenylmethyl
polysiloxane |
G43
|
DB-1301,
DB-624, DB-624UI, VF-1301ms, VF-624ms, CP-1301 |
BP624
|
ZB-624
|
OPTIMA 1301, OPTIMA 624
|
SPB-624
|
AT-624,
AT-1301 |
007-1301,
007-624 |
|
cyanopropylmethyl phenylmethyl
polysiloxane |
G46
|
DB-1701P,
DB-1701, CP-Sil 19 CB, VF-1701ms, VF-1701 Pesticides |
BP10
|
ZB-1701,
ZB-1701P |
OPTIMA 1701
|
Equity-1701
|
AT-1701
|
007-1701
|
|
trifluoropropylmethyl polysiloxane
|
G6
|
DB-210,
DB-200, VF-200ms |
|
|
OPTIMA 210
|
|
AT-210
|
|
|
polyethylene glycol
|
G16, G20, G39
|
HP-INNOWax, CP-Wax 52 CB, VF-WAX MS
|
|
ZB--WAXplus
|
OPTIMA WAXplus
|
Supelcowax-10
|
AT-WAX
|
PLOT GC Columns
Restek
(Phase Description) |
Porous
Layer |
Application
|
Supelco
|
Alltech
|
Agilent
(J&W, Varian, Chrompack) |
Quadrex
|
Aluminum oxide
|
C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons
|
Alumina-sulfate
|
AT-Alumina
|
GS-Alumina,
CP-Al203/Na2SO4 |
|
|
Aluminum oxide
|
C1-C8 hydrocarbons; C1-C5 isomers purity analysis of ethylene, propylene, butene, and butadiene
|
Alumina-chloride
|
|
GS-Alumina KCl,
HP PLOT Al203, CP-Al203/KCl |
||
Aluminum oxide
|
Multi-halogenated alkanes, C1-C5 range chlorofluorocarbons (CFC)
|
Unique Product | ||||
Aluminum oxide
|
Trace analysis of methyl acetylene, propadiene, and acetylene
|
|
|
Select Al203 MAPD
|
|
|
Molecular sieve 5A
|
Permanent gas analysis (He, Ne, Ar, O2, N2, Xe, Rn, CH4, and CO)
|
Molsieve 5A
|
AT-Molesieve
|
HP PLOT Molesieve,
CP-Molsieve 5A |
PLT-5A
|
|
100% Divinylbenzene
|
High retention for solvents, alcohols, polar volatiles, CO2, and ppm-level water in solvents
|
Supel-Q-PLOT
|
AT-Q
|
HP PLOT Q,
CP-PoraPLOT Q, CP-PoraBOND Q |
|
|
Rt-QS-BOND
[intermediate polarity porous polymer (polarity between Q-BOND and S-BOND)] |
Intermediate polarity porous polymer
|
Neutral solvents, ketones, esters, and hydrocarbons; baseline separation of ethane, ethene, and acetylene
|
|
|
GS-Q
|
|
DVB vinylpyridine polymer
|
Light gases in ethylene and propylene; ketones, esters, hydrocarbons
|
|
|
CP-PoraPLOT S
|
|
|
Rt-U-BOND
(polar porous ploymer) |
DVB ethylene glycol-dimethylacrylate polymer
|
More retention for polar compounds; trace H2S, COS, and mercaptans in hydrocarbon streams
|
|
|
HP PLOT U,
CP-PoraPLOT U, CP-PoraBOND U |
|
GNOT3472-UNV